Characterization of a total power radiometer

The performance parameters of a total power radiometer designed as a noise measurement system for the frequency range of 12-18 GHz were investigated. The total power radiometer included a low-noise radio frequency section, a narrow-band intermediate frequency section, an average power detector, and a symmetric microwave switch. The radiometer's stability versus time was 0.343 \times 10-5 mW/h and its stability against temperature fluctuation was 0.0035 mW/K. The temperature fluctuation of the radiometer was less than 4 mK. We proved that there was no need for active temperature control to obtain stable radiometer gain.

Characterization of a total power radiometer

The performance parameters of a total power radiometer designed as a noise measurement system for the frequency range of 12-18 GHz were investigated. The total power radiometer included a low-noise radio frequency section, a narrow-band intermediate frequency section, an average power detector, and a symmetric microwave switch. The radiometer's stability versus time was 0.343 \times 10-5 mW/h and its stability against temperature fluctuation was 0.0035 mW/K. The temperature fluctuation of the radiometer was less than 4 mK. We proved that there was no need for active temperature control to obtain stable radiometer gain.

___

  • A. Einstein, “Investigations on the theory of the Brownian movement I (On the movement of small particles suspended in a stationary liquid demanded by the molecular-kinetic theory of heat)”, Annals of Physics, Vol. 17, pp. 549-560, 1905.
  • J.B. Johnson, “Thermal agitation of electricity in conductors”, Physical Review, Vol. 32, pp. 97-109, 1928.
  • H. Nyquist, “Thermal agitation of electric charge in conductors”, Physical Review, Vol. 32, pp. 110-113, 1928.
  • R.H. Dicke, “The measurement of thermal radiation at microwave frequencies”, Review of ScientiŞc Instruments, Vol. 17, pp. 268-275, 1946.
  • A.J. Estin, C.L. Trembath, J.S. Wells, W.J. Daywitt, “Absolute measurement of temperatures of microwave noise sources”, IRE Transactions on Instrumentation, Vol. 9, pp. 209-213, 1960.
  • J.S. Wells, W.C. Daywitt, C.K.S. Miller, “Measurement of effective temperatures of microwave noise sources”, IEEE Transactions on Instrumentation and Measurement, Vol. 13, pp. 17-28, 1964.
  • P.I. Somlo, D.L. Hollyway, “The Australian National Standards Laboratory X-band radiometer for the calibration of noise sources”, IEEE Transactions on Microwave and Techniques, Vol. 16, pp. 664-666, 1968.
  • D.J. Blundell, E.W. Houghton, M.W. Sinclair, “Microwave noise standards in the United Kingdom”, IEEE Trans- actions on Instrumentation and Measurement, Vol. 21, pp. 484-488, 1972.
  • M.S. Hersman, G.A. Gene, “Sensitivity of the total power radiometer with periodic absolute calibration”, IEEE Transactions on Microwave Theory and Techniques, Vol. 29, pp. 32-40, 1981.
  • D.V. Land, A.P. Lewvick, J.W. Hand, “The use of the Allan deviation for the measurement of the noise and drift performance of microwave radiometers”, Measurement Science and Technologies, Vol. 18, pp. 1917-1928, 2007.
  • S. Dia, B. Godara, F. Alicalapa, A. Fabre, “Ultra wide-band : state of the art; implementation of a performance- controllable low-noise ampliŞer”, Turkish Journal of Electrical Engineering & Computer Sciences, Vol. 13, pp. 1-22, F.T. Ulaby, R.K. Moore, A.K. Fung, Microwave Remote Sensing: Active and Passive, Volume 1, Microwave Remote Sensing Fundamentals and Radiometry, Norwood, Artech House, 1981.
  • J. Randa, D.K. Walker, “On-wafer measurement of transistor noise parameters at NIST”, IEEE Transactions on Instrumentation and Measurement, Vol. 56, pp. 551-554, 2007.
  • S.P. Pucic, “Derivation of the system equation for null-balanced total-power radiometer system NCS1”, Journal of Research of the National Institute of Standards and Technology, Vol. 99, pp. 55-63, 1994.
  • M.W. Sinclair, Microwave Measurements, London, Peter Peregrinus Ltd., 1989.
  • G. Evans, C.W. McLeish, RF Radiometer Handbook, Norwood, Artech House, 1977.
  • D.A. Thompson, R.L. Rogers, J.H. Davis, “Temperature compensation of total power radiometers”, IEEE Trans- actions on Microwave Theory and Techniques, Vol. 51, pp. 2073-2078, 2003.
  • S.P. Pucic, “A null-balanced total-power radiometer system NCS1”, Journal of Research of the National Institute of Standards and Technology, Vol. 99, pp. 45-53, 1994.
  • R. Swarup, J.R. Anand, P.S. Negi, “On 30 MHz TE11mode piston attenuator”, Review of ScientiŞc Instruments, Vol. 72, pp. 1858-1861, 2001.
  • C.K.S. Miller, W.C. Daywitt, M.G. Arthur, “Noise standards, measurements, and receiver noise deŞnitions”, Proceedings of the IEEE, Vol. 55, pp. 865-877, 1967.
  • P. Racette, R.H. Lang, “Radiometer design analysis based upon measurement uncertainty”, Radio Science, Vol. 40, Bureau International des Poids et Measures (BIPM), Calibration and Measurement Capabilities, 2010. Available at http://kcdb.bipm.org/appendixC/country list.asp?Iservice=EM/RF.11.4.1.