In this study we aimed to detect the effect of different centrifugation temperatures on coagulation parameters in the emergency laboratory. Duplicate samples were collected into sodium citrate tubes from 45 patients and centrifuged concurrently with non-cooling (group 1) and cooling centrifuges (Group 2) in Ankara Numune Training and Research Hospital emergency laboratory. Inner temperatures of the centrifuges were recorded during the study. Afterwards, PT, aPTT, D-dimer and fibrinogen values were determined. No statistically significant difference was detected between groups for any of the parameters tested (PT, aPTT, D-dimer and fibrinogen) (p> 0,05). Results of the present study show that there is no significant effect of internal temperature of the centrifuge device used on blood coagulation parameters.
___
Elizabeth M, Van Cott MD, Micheal Laposata Ph.D: MD. Coagulation. In: Jacobs DS, et al., editors. The laboratory test handbook. 5th ed. Cleveland, OH: Lexi-Comp; 2001; p.327-58.
Lundberg G. Acting on significant laboratory results. JAMA 1981; 245:1762–3.
Lima-Oliveira G, Salvagno GL, Lippi G, et al. Could light meal jeopardize laboratory coagulation tests? Biochem Med. 2014;24:343–9.
Koçak FE, Yöntem M, Yücel O, et al. The effects of transport by pneumatic tube system on blood cell count, erythrocyte sedimentation and coagulation tests. Biochem Med. 2013;23:206–10.
Bonar R, Favaloro EJ, Adcock DM. Quality in coagulation and haemostasis testing. Biochem Med. 2010;20:184–99.
Lippi G, Salvagno GL, Poli G, et al. Influence of centrifugation temperature on routine coagulation testing. Clin Chem. 2006;52:537-538.
Clinical and Laboratory Standards Institute.Collection, transport, and processing of bloodspecimens for testing plasma-based coagulation assays and molecular hemostasis assays; approvedguideline H21-A5, 5rd ed. Wayne, PA: CLSI, 2008.
westgard.com/biodatabasel.htm Desirable Specifications forTotal Error, Imprecision, and Bias, derived from intra- and inter-individual biologic variation, Updated for 2014.
Ricos C, Alvarez V, Cava F, et al. Current databases on biologic variation: pros, cons, and progress. Scand J Clin Lab Invest. 1999;59:491-500.
Valenstein PN, Sirota RL. Identification errors in pathology andlaboratory medicine. Clin Lab Med. 2004;24:979-96.
Schiff GD, Hasan O, Kim S, et al. Diagnostic error in medicine: analysis of 583 physician-reported errors. Arch Intern Med. 2009;169:1881-7.
International Organization for Standardization (ISO). ISO 15189:2012: Medical laboratories: Particular requirements for quality and competence. Geneva, Switzerland: ISO; 2012.
Yilmaz FM, Kıral S, Boğdaycıoglu N, et al. An underestimated preanalytical error source: Centrifuge temperature. Turk J Biochem. 2013; 38:356-9.
Van Geest-Daalderop JH, Mulder AB, Boonman-de Winter LJ, et al. Preanalytical variables and off-site blood collection: influences on the results of the prothrombin time/international normalized ratio test and implications for monitoring of oral anticoagulant therapy. Clin Chem. 2005;51:561-8.
Adcock D, Kressin D, Marlar R.A, The effect of time and temperature variables on routine coagulation tests. Blood Coagulation and fibrinolysis. 1998;9:463-70.