VARIABLE CAPACITY ABSORPTION COOLING SYSTEM PERFORMANCE FOR BUILDING APPLICATION

The increasing energy costs and environmental awareness call for a shift towards some interesting energy alternatives preferably the use of renewable energy. The present study investigates the impact of varying cooling capacity and other operating parameters in a single-effect absorption refrigeration system, using the concept of energy and exergy as a building heating/cooling alternative. The solar heat is used as an input to the generator of absorption refrigeration system. The results obtained from investigation revealed that variation in cooling capacity influences coefficient of performance (COP), exergy loss in different components as well as exergy efficiency. The values of COPcooling and COPheating lies in the range of 0.71-0.89 and 1.71-1.89 respectively for variations in cooling capacities ranging from 1 TR to 20 TR at maximum generator temperature of 80oC. However, exergy efficiency of the system lies in the range of 0.32-0.41 for same variation in cooling capacities. It has also been established that an increase in evaporator temperature and at maximum cooling capacity both COPcooling and COPheating shows an increasing trend. The exergy efficiency also shows maximum value at the highest cooling capacity at a particular evaporator temperature which further with an increase in evaporator temperature shows a decreasing trend. The irreversibility behavior in all the components i.e., solution heat exchanger, absorber, generator, evaporator and condenser shows an expected trend with the variation in cooling capacity. Hence, use of the above mentioned system as a heating and/or cooling alternative for buildings is suggested.

___

  • [1] Ventas, R., Lecuona, A., Vereda, C., Legrand, M. (2016). Two-stage double-effect ammonia/lithium nitrate absorption cycle. Applied Thermal Engineering, 94, 228 - 237.
  • [2] Siddiqui, M. U., Said, S. A. M. (2015). A review of solar powered absorption systems. Renewable and Sustainable Energy Reviews, 42,93 - 115.
  • [3] Pintaldi, S. S., Taylor, R. A., White, S. D., Morrison, G. L., Rosengarten, G. (2015). Solar-Powered Absorption Chillers for Air-Conditioning Applications: Simulation and Techno-Economic Evaluation, In Proceedings of 9th International Conference on Energy Sustainability, collocated with ASME 2015 Power Conference, 13th ASME International Conference on Fuel Cell Science, Engineering and Technology, and the ASME 2015 Nuclear Forum, American Society of Mechanical Engineers.
  • [4] Ghafoor, A., Munir, A. (2015). World-wide overview of solar thermal cooling technologies. Renewable and Sustainable Energy Reviews, 43, 763-774.
  • [5] Lange, M. F. D., Verouden, K. J. F. M., Vlugt, T. J. H., Gascon, J., Kapteijn, F. (2015). Adsorption-driven heat pumps: the potential of metal–organic frameworks. Chemical Reviews, 115(22), 12205 - 12250.
  • [6] Sabek, S., Nasr, K. B., Chouikh, R., Guizani, A. (2015). Analytical Study of a Heat Recovery/Desiccant Cooling System under Tunisian Climatic Conditions. Journal of Clean. Energy Technologies, 3(3), 159 - 164.
  • [7] Sultana, P., Wijeysundera, N. E., Ho, J. C., Yap, C., Chang, T. K. (2015). Effect of vapour absorption enhancement in solar-heat driven air-conditioning system. Journal of Clean Energy Technologies, 3(1), 43 - 47.
  • [8] Quan, S. H., Xu, Z. Y., Wang, H., Wang, R. (2015). A solar/gas fired absorption system for cooling and heating in a commercial building. Energy Procedia, 70, 518 - 528.
  • [9] Li, Y., Hu, R. (2016).Exergy-analysis based comparative study of absorption refrigeration and electric compression refrigeration in CCHP systems. Applied. Thermal. Engineering, 93, 1228 - 1237.
  • [10] Al-Ugla, A. A., El-Shaarawi, M. A. I., Said, S. A. M., Al-Qutub, A. M. (2016). Techno-economic analysis of solar-assisted air-conditioning systems for commercial buildings in Saudi Arabia.Renewable and Sustainable Energy Reviews,54, 1301-1310.
  • [11] Gupta, A., Anand, Y., Anand, S., Tyagi, S. K. (2015). Thermodynamic optimization and chemical exergy quantification for absorption-based refrigeration system. Journal of Thermal Analysis and Calorimetry, 122 (2), 893-905.
  • [12] Abdullah, M. O., Hien, T. C. (2010). Comparative analysis of performance and techno- economics for a H2O-NH3-H2 absorption refrigerator driven by different energy sources. Applied Energy, 87(5),1535 - 1545.
  • [13] Arora, A., Dixit, M., Kaushik, S. C. (2016). Energy and exergy analysis of a double effect parallel flow LiBr/H2O absorption refrigeration system. Journal of Thermal Engineering, 2(1), 541 – 549.
  • [14] Xu, X., Vignarooban, K., Xu, B., Hsu, K., Kannan, A. M. (2016). Prospects and problems of concentrating solar power technologies for power generation in the desert regions. Renewable and Sustainable Energy Reviews, 53, 1106 -1131.
  • [15] Sanjuan, C., Soutullo, S., Heras, M. R. (2010). Optimization of a solar cooling system with interior energy storage. Solar Energy, 84 (7), 1244-1254.
  • [16] Anand, S., Gupta, A., Tyagi, S. K. (2014). Renewable energy powered evacuated tube collector refrigerator system. Mitigation and Adaptation Strategies for Global Change, 19(7), 1077-1089.
  • [17] Gong, S., Boulama, K.G. (2015). Advanced exergy analysis of an absorption cooling machine: Effects of the difference between the condensation and absorption temperatures. International Journal of Refrigeration, 59, 224 - 234.
  • [18] Pilatowsky, I., Rivera, W., Romero, R. J. (2001). Thermodynamic analysis of monomethylamine-water solution in a single stage solar absorption refrigeration cycle at low generator temperatures. Solar Energy Material and Solar Cells, 70(3), 287-300.
  • [19] Lostec, B. L., Galanis, N., Millette, J. (2012). Experimental study of an ammonia-water absorption chiller. International Journal of Refrigeration, 35(8), 2275 -2286.
  • [20] Kaynakli, O., Saka, K., Kaynakli, F. (2015). Energy and exergy analysis of a double effect absorption refrigeration system based on different heat sources. Energy Conversion and Management, 106, 21 - 30.
  • [21] Vaibhav, J., Sachdeva, G., Kachhwaha, S. S. (2015).Thermodynamic modelling and parametric study of a low temperature vapour compression-absorption system based on modified Gouy-Stodola equation. Energy, 79, 407 - 418.
  • [22] Adewusi, S. A., Zubair, S. M. (2004). Second law based thermodynamic analysis of ammonia-water vapor absorption refrigeration system. Energy Conversion and Management, 45 (15), 2355 - 2369.
  • [23] Ezzine, N. B., Barhoumi, M., Mejbri, K., Chemkhi, S.,Bellagi, A. (2004). Solar cooling with the absorption principle: first and Second Law analysis of an ammonia-water double-generator absorption chiller. Desalination, 168, 137-144.
  • [24] Paurine, A., Maidment, G. G., Eames, I. W., Missenden, J. F. (2012). Development of a thermo-gravity pumping mechanism for circulating the working fluids in a novel LiBr–H2O vapor absorption refrigeration (VAR) system. Applied Thermal Engineering, 47, 25-33.
  • [25] Roy, S., Maiya, M. P. (2013). Analysis of pinch point in liquid–vapour heat exchanger of R134a- DMAC vapour absorption refrigeration system. Applied Thermal Engineering, 50(2), 1619-1626.
  • [26] Suresh, M., Mani, A. (2013). Heat and mass transfer studies on a compact bubble absorber in R134a-DMF solution based vapour absorption refrigeration system. International Journal of Refrigeration, 36(3), 1004 - 1014.
  • [27] Swarnkar, S. K., Murthy, S. S., Gardas, R. L., Venkatarathnam, G. (2014). Performance of a vapour absorption refrigeration system operating with ionic liquid-ammonia combination with water as co-solvent. Applied Thermal Engineering, 72(2), 250-257.
  • [28] Buckmaster D. J., Abramson, A. R. (2015). Characterization of the effects of insulating wall paint on space conditioning in a room. Journal of Thermal Engineering, 1(1), 322-329.
  • [29] Anand, Y., Gupta, A., Maini, A., Gupta, A., Sharma, A., Khajuria, A., Gupta, S., Sharma, S., Anand, S.,Tyagi, S. K. (2014). Comparative Thermal Analysis of Different Cool Roof Materials for Minimizing Building Energy Consumption. Journal of Engineering.
  • [30] Doseva, N., Chakyrova, D. (2015). Energy and exergy analysis of cogeneration system with biogas engines. Journal of Engineering, 1(3), 391-401.
  • [31] Anand, S., Gupta, A., Tyagi, S.K. (2013). Thermodynamic analysis of 1 TR biogas based NH3-H2O vapor absorption system, In proceedings of Recent Advances in Bio-Energy Research, 2, 79 – 98.
  • [32] Klein, S. A., Alvarado, F. (2013). Engineering Equation Solver, Version 9.462, F-Chart Software: Middleton, WI.