Performance analysis of a two stage pad cooling system in broiler houses

The cooling performance of a traditional (control) and two stage evaporative pad cooling system (experiment), including pad and fan with tunnel ventilation, for poultry houses and the growth performance of broilers reared in these systems was compared in a study performed during extreme summer temperatures. The experimental unit had a two stage pad cooling system, which consisted of underground tubes and a box, followed by a pad cooling system with tunnel ventilation. The control unit had a traditional evaporative cooling system, including pad and fan with tunnel ventilation. Air temperature, relative humidity, and saturation efficiency were used to determine the cooling performance of the systems. Live body weight gain, feed conversion ratio, and mortality rate were used to monitor the growth performance of broilers raised in these systems. The air temperature and relative humidity of incoming house and exhausted air in the two stage pad cooling system were found to be significantly lower than those of the traditional system (P < 0.05). The cooling efficiency or saturation efficiency in the two stage cooling system was found to be slightly greater than that of the traditional system. Body weight gain was also significantly influenced by the cooling system (P < 0.05). The results indicated that two stage pad cooling is a more efficient method to alleviate heat stress in broilers during heat stress conditions and to improve growth performance.

Performance analysis of a two stage pad cooling system in broiler houses

The cooling performance of a traditional (control) and two stage evaporative pad cooling system (experiment), including pad and fan with tunnel ventilation, for poultry houses and the growth performance of broilers reared in these systems was compared in a study performed during extreme summer temperatures. The experimental unit had a two stage pad cooling system, which consisted of underground tubes and a box, followed by a pad cooling system with tunnel ventilation. The control unit had a traditional evaporative cooling system, including pad and fan with tunnel ventilation. Air temperature, relative humidity, and saturation efficiency were used to determine the cooling performance of the systems. Live body weight gain, feed conversion ratio, and mortality rate were used to monitor the growth performance of broilers raised in these systems. The air temperature and relative humidity of incoming house and exhausted air in the two stage pad cooling system were found to be significantly lower than those of the traditional system (P < 0.05). The cooling efficiency or saturation efficiency in the two stage cooling system was found to be slightly greater than that of the traditional system. Body weight gain was also significantly influenced by the cooling system (P < 0.05). The results indicated that two stage pad cooling is a more efficient method to alleviate heat stress in broilers during heat stress conditions and to improve growth performance.

___

  • Mashaly, M.M., Hendricks, G.L., Kalama, M.A., Gehad, A.E., Abbas, A.O., Patterson, P.H.: Eff ect of heat stress on production parameters and immune responses of commercial laying hens. Poultry Sci., 2004; 83: 889-94.
  • Wolfenson, D., Bachrach, D., Maman, M., Graber, Y., Rozenboim, I.: Evaporative cooling of ventral regions of the skin in heat-stressed laying hens. Poultry Sci., 2001: 80: 958-64.
  • North, M.O., Bell, D.D.: Commercial Chicken Production Manual, Fourth Edition. Chapman & Hall, New York, 1990; 192-193. 4. Donald, J.: Getting the most from evaporative cooling systems in tunnel ventilated broiler houses. World Poultry, 2000; 16: 35-39. 5. Dozier, W.A., Lott, B.D., Branton, S.L.: Live performance of male broilers subjected to constant or increasing air velocities at moderate temperatures with a high dew point. Poultry Sci., 2005; 84: 1328-31.
  • Gunhan, T., Demir, V., Yagcioglu, A.K.: Evaluation of the Suitability of Some Local Materials as Cooling Pads. Biosystems Engineering, 2007; 96: 369-367.
  • Jain, D., Tiwari, G.N.: Modeling and optimal design of evaporative cooling system in controlled environment greenhouse. Energy Conversion and Management, 2002; 43: 2235-2250. 8. Kittas, C., Bartzanas, T., Jaff rin, A.: Temperature gradients in a partially shaded large greenhouse equipped with evaporative cooling pads. Biosystems Engineering, 2003; 85: 87-94. 9. Uğurlu, N., Kara, M.: Th e cooling performance of wet pads and their eff ects on reduction of the inside temperature a cage house. Turk. J. Agric. For., 2000; 24: 79-86.
  • Willits, D.H.: Cooling fan-ventilated greenhouse: a modeling study. Biosystems Engineering, 2003; 84: 314-329.
  • Dozier, W.A., Lott, B.D., Branton, S.L.: Growth responses of male broilers subjected to increasing air velocities at high ambient temperatures and a high dew point. Poultry Sci., 2005; 84: 962-6.
  • Simmons, J.D., Miles, D.M., Lott, B.D.: Th e eff ects of high air velocity on broiler performance. Tektran. United States Department of Agriculture. Agricultural Research Service, 2002.
  • Hulzebosch, J.: How to keep your birds cool. World Poultry, 2005; 21: 32-4.
  • Alchalabi, D.: Two-stage air cooling for very hot environments. Poultry Int., 2001; 10: 21-23.
  • Botcher, R.W., Baugman, G.R., Kesler, D.J.: Evaporative cooling using a pneumatic misting system. Trans. ASAE, 1989; 32: 671- 676.
  • Snedecor, G.W., Cochran, W.G.: Statistical Methods, Eighth Edition. Iowa State University Press, Ames, IA, USA. 1989.
  • SPSS® 13.00 Computer Soft ware: SPSS Inc, Chicago, IL, USA. 2004.
  • Anonymous: Tips to minimizing the impact of hot weather. World Poultry, 1997; 13: 24-25.
  • Donald, J., Eckman, M., Simpson, G.: Keys to getting good performance from your evaporative cooling system. Th e Alabama Poultry Engineering and Economics Newsletter. 2000; No: 5.
  • Bucklin, R.A.: Fan and Pad Greenhouse Evaporative Cooling Systems. University of Florida Cooperative Extension Services. 2004; www//edis.ifas.ufl .edu/BODY_AE069.
  • Dai, Y.J., Sumathy, K.: Th eoretical study on a cross-fl ow direct evaporative cooler using honeycomb paper as packing material. Applied Th ermal Engineering, 2002; 22: 1417-1430.
  • Willis, W.L., Ouart, M.D., Quarles, C.L.: Eff ect of an evaporative cooling and dust control system on rearing environment and performance of male broiler chickens. Poultry Sci., 1987; 66: 1590-3.
Turkish Journal of Veterinary and Animal Sciences-Cover
  • ISSN: 1300-0128
  • Yayın Aralığı: Yılda 6 Sayı
  • Yayıncı: TÜBİTAK
Sayıdaki Diğer Makaleler

Performance analysis of a two stage pad cooling system in broiler houses

Metin PETEK, Serdal DİKMEN, Mehmet Mustafa OĞAN

Vaginal prolapse related to ovarian granulosa cell tumor in an Anatolian Shepherd.

Deniz NAK, Aylin ALASONYALILAR DEMİRER, Bilginer TUNA, Yavuz NAK, M. Özgür ÖZYİĞİT

Relations between electrical conductivity, somatic cell count, California mastitis test and some quality parameters in the diagnosis of subclinical mastitis in dairy cows

Güven KAŞIKÇI, Ömer ÇETİN, Enver Barış BİNGÖL, Mehmet Can GÜNDÜZ

Antioxidative and antimicrobial effects of garlic in ground camel meat

Hamid R. GHEISARI, Vahid R. RANJBAR

Serum protein fractions in Brazilian-breed donkeys using agarose gel electrophoresis

Paulo Henrique CAVALCANTE, Andréa Cristina C. SILVA, Sidnei M. SAKAMOTO, Benito SOTO BLANCO

Optimum timing for operation in bitches with pyometra related to endotoxemia

Melih UÇMAK, Çağatay TEK, Mehmet C. GÜNDÜZ, Ahmet SABUNCU, Adem ŞENÜNVER

Unusual anal atresia in a lamb

Siavash AHMADI NOORBAKHSH

Interfragmental fixation of rostral mandibular fracture with cerclage wire in a thoroughbred English horse

Mehmet Alper ÇETİNKAYA, Alper DEMİRUTKU

A determination of growth hormone receptor gene polymorphisms in East Anatolian Red cattle, South Anatolian Red cattle, and Turkish Grey cattle

Kemal Özdem ÖZTABAK, AKIŞ Iraz AKAD, Ahmet MENGİ

Equine grass sickness in Cyprus: a case report

F. Kypros PROTOPAPAS, M. Kyriakos Alexandros SPANOUDES, E. Nikolaos DIAKAKIS, D. Georgia BRELLOU