Sağ internal jugüler ven aracılığıyla santral venöz kanülasyon yaygın olarak kullanılan bir teknik olup, kateterin yerleştirilme aşaması, ilerletme aşaması ve çıkarılma aşaması gibi farklı aşamalarda komplikasyonlara yol açabilir. Santral venöz kateterin malpozisyonu, tehlikeli sonuçlara da yol açabilmektedir. Bu yazıda, kateterin çıkarılma aşamasında fark edilen, santral venöz kateterin yedinci vertebral foramen içerisindeki sağ vertebral vene yanlışlıkla yerleştirildiği 74 yaşında erkek bir olgu sunuldu
Central venous cannulation through the right internal jugular vein, which is a widely used technique, may lead to complications at different stages, including catheter placement stage, indwelling stage and the removal stage. Malposition of the central venous catheter may also result in catastrophic consequences. In this article, we report 74-year-old male case with misplaced central venous catheter into the right vertebral vein in seventh vertebral foramen, which was detected at the catheter removal stage. "> [PDF] Inadvertent vertebral vein catheterisation during transjugular vein cannulation: a rare complication | [PDF] Transjuguler ven kanülasyonu sırasında yanlışlıkla vertebral ven kateterizasyonu: Nadir bir komplikasyon Sağ internal jugüler ven aracılığıyla santral venöz kanülasyon yaygın olarak kullanılan bir teknik olup, kateterin yerleştirilme aşaması, ilerletme aşaması ve çıkarılma aşaması gibi farklı aşamalarda komplikasyonlara yol açabilir. Santral venöz kateterin malpozisyonu, tehlikeli sonuçlara da yol açabilmektedir. Bu yazıda, kateterin çıkarılma aşamasında fark edilen, santral venöz kateterin yedinci vertebral foramen içerisindeki sağ vertebral vene yanlışlıkla yerleştirildiği 74 yaşında erkek bir olgu sunuldu "> Sağ internal jugüler ven aracılığıyla santral venöz kanülasyon yaygın olarak kullanılan bir teknik olup, kateterin yerleştirilme aşaması, ilerletme aşaması ve çıkarılma aşaması gibi farklı aşamalarda komplikasyonlara yol açabilir. Santral venöz kateterin malpozisyonu, tehlikeli sonuçlara da yol açabilmektedir. Bu yazıda, kateterin çıkarılma aşamasında fark edilen, santral venöz kateterin yedinci vertebral foramen içerisindeki sağ vertebral vene yanlışlıkla yerleştirildiği 74 yaşında erkek bir olgu sunuldu
Central venous cannulation through the right internal jugular vein, which is a widely used technique, may lead to complications at different stages, including catheter placement stage, indwelling stage and the removal stage. Malposition of the central venous catheter may also result in catastrophic consequences. In this article, we report 74-year-old male case with misplaced central venous catheter into the right vertebral vein in seventh vertebral foramen, which was detected at the catheter removal stage. ">

Inadvertent vertebral vein catheterisation during transjugular vein cannulation: a rare complication

Sağ internal jugüler ven aracılığıyla santral venöz kanülasyon yaygın olarak kullanılan bir teknik olup, kateterin yerleştirilme aşaması, ilerletme aşaması ve çıkarılma aşaması gibi farklı aşamalarda komplikasyonlara yol açabilir. Santral venöz kateterin malpozisyonu, tehlikeli sonuçlara da yol açabilmektedir. Bu yazıda, kateterin çıkarılma aşamasında fark edilen, santral venöz kateterin yedinci vertebral foramen içerisindeki sağ vertebral vene yanlışlıkla yerleştirildiği 74 yaşında erkek bir olgu sunuldu

Transjuguler ven kanülasyonu sırasında yanlışlıkla vertebral ven kateterizasyonu: Nadir bir komplikasyon

Central venous cannulation through the right internal jugular vein, which is a widely used technique, may lead to complications at different stages, including catheter placement stage, indwelling stage and the removal stage. Malposition of the central venous catheter may also result in catastrophic consequences. In this article, we report 74-year-old male case with misplaced central venous catheter into the right vertebral vein in seventh vertebral foramen, which was detected at the catheter removal stage.

___

  • 1. Patel RY, Friedman A, Shams JN, Silberzweig JE. Central venous catheter tip malposition. J Med Imaging Radiat Oncol 2010;54:35-42. doi: 10.1111/j.1754-9485.2010.02143.x.
  • 2. Webb JG, Simmonds SD, Chan-Yan C. Central venous catheter malposition presenting as chest pain. Chest 1986;89:309-12.
  • 3. Balethbail S, Singha SK, Gayatri P. Vertebral artery pseudoaneurysm a complication after attempted internal jugular vein catheterization in a neurosurgical patient. J Neurosurg Anesthesiol 2011;23:53-4. doi: 10.1097/ ANA.0b013e3181f20616.
  • 4. Muhm M, Sunder-Plassmann G, Druml W. Malposition of a dialysis catheter in the accessory hemiazygos vein. Anesth Analg 1996;83:883-5.
  • 5. Aoki H, Mizobe T, Nozuchi S, Hatanaka T, Tanaka Y. Vertebral artery pseudoaneurysm: a rare complication of internal jugular vein catheterization. Anesth Analg 1992;75:296-8.
  • 6. Bernik TR, Friedman SG, Scher LA, Safa T. Pseudoaneurysm of the subclavian-vertebral artery junction--case report and review of the literature. Vasc Endovascular Surg 2002;36:461-4.
  • 7. Piechowiak H, Büchels H, Ingrisch H, Hess H. Arteriovenous fistula of the vertebral artery: a rare complication following central venous catheterization. A case report. Anaesthesist 1984;33:327-9. [Abstract]
  • 8. dos Santos ML, Demartini Z Jr, Matos LA, Borges MA, Spotti AR, Tognola WA. Radiculopathy due to iatrogenic fistula between subclavian artery and internal jugular vein. Clin Neurol Neurosurg 2008;110:80-2.
  • 9. Winston CB, Wechsler RJ, Kane M. Vertebral vein migration of a long-term central venous access catheter: a cause of brachial plexopathy. J Thorac Imaging 1994;9:98-100.
Türk Göğüs Kalp Damar Cerrahisi Dergisi-Cover
  • ISSN: 1301-5680
  • Yayın Aralığı: 4
  • Başlangıç: 1991
  • Yayıncı: Bayçınar Tıbbi Yayıncılık
Sayıdaki Diğer Makaleler

Mitral valve replacement surgery in isolated dextrocardia: a case report

Ahmet Barış DURUKAN, Cem YORGANCIOĞLU, Halil İbrahim UÇAR, Hasan Alper GÜRBÜZ, Fatih Tanzer SERTER

Akut derin ven trombozu sonrası yaşam kalitesi: VEINES-QOL/Sym ölçeğinin kültürel adaptasyonu, güvenirliği ve geçerliği: Türkçe versiyon çalışması

Yasemin ÇIRAK, Zehra KARAHAN, Ufuk DEMİRKILIÇ, Sema SAVCI

Inadvertent vertebral vein catheterisation during transjugular vein cannulation: a rare complication

Çiğdem GÜÇLÜ, Sema TURAN, Dilek KAZANCI, Sarper ÖKTEN, Bahar AYDINLI, İhsan AYIK, Murat TAŞ, Özcan ERDEMLİ

Kalıcı hemodiyaliz kateterleri: Ne kadar kalıcı?

Deniz ŞAHİN, Şadan YAVUZ, Aslı Gül AKGÜL, Ersan ÖZBUDAK, A. Ahmet ARIKAN, Duygu DURMAZ, Turan BERKİ, Muhip KANKO

The effects of perioperative ultrafiltration on postoperative outcomes in dialysis-dependent patients undergoing open heart surgery

Hüseyin Ali TÜNEL, Rıza TÜRKÖZ, Öner GÜLCAN, Orhan Saim DEMİRTÜRK, İsa COŞKUN, Yücel ÇÖLKESEN

Aort koarktasyon zemininde gelişen aort diseksiyonunda iki aşamalı tamir:Olgu sunumu

İlker MATARACI, Özge ALTAŞ, Mehmet Kaan KIRALİ, Kamil BOYACIOĞLU

Middle lobe syndrome: a retrospective analysis

Atalay ŞAHİN, Fatih METEROĞLU, Tahir Sevval EREN

Concomitant giant cardiopericardial and right pulmonary hydatid cysts

Aylin ÇALLI ORGEN, Kenan Can CEYLAN, Ali GÜRBÜZ, Ufuk YETKİN, İsmail YÜREKLİ

Initial experiences with Corevalve® for transcatheter aortic valve implantation in Turkey: two case reports

Oğuz YILMAZ, Servet ÖZTÜRK, Harun ARBATLI, Deniz ŞENER, Türker BARAN, Ekrem SELÇUKOĞLU, Bingür SÖNMEZ

Kırk beş yaş altı kadın ve erkeklerde koroner arter cerrahi sonuçları

Taner İYİGÜN, Müzeyyen İYİGÜN, İhsanE BAKIR, Mehmet YENİTEZİ, Mehmet KAYA

Academic Researches Index - FooterLogo