Distal radius measurements and efficacy of fixed-angle locking volar plates

For surgical treatment of unstable distal radius fractures, fixed-angled locking volar plate fixation is becoming popular nowadays because of some advantages over other surgical techniques. In this article, we discuss the fitting of fixed-angle locking volar plates to the distal radius in relation to the changes in the distal radial angles. Materials and methods: First, we took conventional radiography images of 18 dried radii and later we measured the palmar subchondral angle, dorsal subchondral angle, mid-subchondral angle, and palmar cortical angle using lateral radiography. Results: According to the measurements, the volar subchondral angles (alpha) ranged from 10.2° to 28.1°, the middle subchondral angles ranged from 55.9° to 93.2°, the dorsal subchondral angles ranged from 77° to 109.6°, and the volar cortical angles ranged from 134.5° to 158.4°. Conclusion: Although fixed-angle locking volar plates are accepted as anatomical, our measurements showed that volar cortical angles and the subchondral angles are variable. Therefore, the term “anatomic distal radius volar plate” should be discussed.

Distal radius measurements and efficacy of fixed-angle locking volar plates

For surgical treatment of unstable distal radius fractures, fixed-angled locking volar plate fixation is becoming popular nowadays because of some advantages over other surgical techniques. In this article, we discuss the fitting of fixed-angle locking volar plates to the distal radius in relation to the changes in the distal radial angles. Materials and methods: First, we took conventional radiography images of 18 dried radii and later we measured the palmar subchondral angle, dorsal subchondral angle, mid-subchondral angle, and palmar cortical angle using lateral radiography. Results: According to the measurements, the volar subchondral angles (alpha) ranged from 10.2° to 28.1°, the middle subchondral angles ranged from 55.9° to 93.2°, the dorsal subchondral angles ranged from 77° to 109.6°, and the volar cortical angles ranged from 134.5° to 158.4°. Conclusion: Although fixed-angle locking volar plates are accepted as anatomical, our measurements showed that volar cortical angles and the subchondral angles are variable. Therefore, the term “anatomic distal radius volar plate” should be discussed.

___

  • Prithishkumar IJ, Francis DV, Nithyanand M, Verghese VD, Samuel P. Morphometry of the distal radius: an osteometric study in the Indian population. Indian J Basic Appl Med Res 2012, 1: 166–171. 9. Freeland AE, Luber KT. Biomechanics and biology of plate fixation of distal radius fractures. Hand Clin 2005; 21: 329–339.
  • Muller M, Allgower M, Schneider R, Willenegger H. Manual of Internal Fixation. 3rd ed. New York, NY, USA: Springer Verlag; 1991. pp. 1–3.
  • Smith DW, Henry MH. The 45 degrees pronated oblique view for volar fixed-angle plating of distal radius fractures. J Hand Surg Am 2004; 29: 703–706.
  • Orbay JL. The treatment of unstable distal radius fractures with volar fixation. Hand Surg 2000; 5: 103–112.
  • Orbay JL, Badia A, Indriago IR, Infante A, Khouri RK, Gonzalez E et al. The extended flexor carpi radialis approach: a new perspective for the distal radius fracture. Tech Hand Up Extrem Surg 2001; 5: 204–211.
  • Windisch G, Clement H, Tanzer K, Feigl G, Grechenig W, Anderhuber F et al. Promontory of radius: a new anatomical description on the distal radius. Surg Radiol Anat 2007; 29: 629–633.
  • Orbay JL, Fernandez DL. Volar fixation for dorsally displaced fractures of the distal radius: a preliminary report. J Hand Surg Am 2002; 27: 205–215.
  • Jupiter JB, Fernandez DL, Toh CL, Fellman T, Ring D. Operative treatment of volar intra-articular fractures of the distal end of the radius. J Bone Joint Surg Am 1996; 78: 1817–1828.
  • Downing ND, Karantana A. A revolution in the management of fractures of the distal radius? J Bone Joint Surg Br 2008; 90: 1271–1275.
  • Cantu RV, Koval KJ. The use of locking plates in fracture care. J Am Acad Orthop Surg 2006; 14: 183–190.
  • Maschke SD, Evans PJ, Schub D, Drake R, Lawton JN. Radiographic evaluation of dorsal screw penetration after volar fixed-angle plating of the distal radius: a cadaveric study. J Hand Surg Am 2008; 33: 1144–1152.
  • Buzzell JE, Weikert DR, Watson JT, Lee DH. Precontoured fixed-angle volar distal radius plates: a comparison of anatomic fit. J Hand Surg Am 2009; 34: 365–366.
  • Jupiter JB. Fractures of the distal end of the radius. J Bone Joint Surg Am 1991; 73: 461–469.
  • Osada D, Kamei S, Masuzaki K, Takai M, Kameda M, Tamai K. Prospective study of distal radius fractures treated with a volar locking plate system. J Hand Surg Am 2008; 33: 691–700.
  • Douthit JD. Volar plating of dorsally comminuted fractures of the distal radius: a 6-year study. Am J Orthop 2005; 34: 140– 147.
  • Perren SM. Evolution of the internal fixation of long bone fractures. The scientific basis of biological internal fixation: choosing a new balance between stability and biology. J Bone Joint Surg Br 2002; 84: 1093–1110.
  • Wright TW, Horodyski M, Smith DW. Functional outcome of unstable distal radius fractures: ORIF with a volar fixed-angle tine plate versus external fixation. J Hand Surg Am 2005; 30: 289–299.
  • Rozental TD, Blazar PE. Functional outcome and complications after volar plating for dorsally displaced, unstable fractures of the distal radius. J Hand Surg Am 2006; 31: 359–365.
Turkish Journal of Medical Sciences-Cover
  • ISSN: 1300-0144
  • Yayın Aralığı: 6
  • Yayıncı: TÜBİTAK
Sayıdaki Diğer Makaleler

Epistaxis in geriatric patients

Alper YÜKSEL, Hanifi KURTARAN, Ekrem Said KANKILIÇ, Nebil ARK, Kadriye Şerife UĞUR, Mehmet GÜNDÜZ

Choroidal thickness in healthy Turkish subjects

Erol COŞKUN, Seydi OKUMUŞ, Bülent GÜRLER, Ramazan YAYUSPAYI, Burak ÖREN, Erdal KAYDU, Ayşegül ÇÖMEZ, İbrahim ERBAĞCI

The diagnostic value of ischemia-modified albumin in the diagnosis of aortic pathology

Oğuz EROĞLU, Süha TÜRKMEN, Ahmet MENTEŞE, Gökalp ALTUN, Süleyman TÜREDİ, Umut ERYİĞİT, Süleyman Caner KARAHAN, Abdülkadir GÜNDÜZ

Ocular surface culture changes in patients after septoplasty

Mahmut ÖZKIRIŞ, Zeliha KAPUSUZ GENCER, Çiğdem KADER, Levent SAYDAM

Acute Q fever among febrile patients in Zahedan, southeastern Iran

Maliheh METANAT, Nahid Sepehri RAD, Roya ALAVI-NAINI, Shahram SHAHREKI, Batool SHARIFI-MOOD, Aida AKHAVAN, Zahra POORMONTASERI

PUVA phototherapy-induced secondary amyloidosis in patients with mycosis fungoides: a rare adverse effect of phototherapy Itır

Ebru ZEMHERİ, İlkin ZİNDANCI, Serkan ŞENOL, Filiz DEMİR2TOPALOĞLU, Özge AKBULAK, Sıdıka Şeyma ÖZKANLI

Right-sided double-lumen tubes: need for design improvement and better insertion technique?

Jean S. BUSSIÈRES, Jérôme LEMIEUX, Jacques SOMMA

PUVA phototherapy-induced secondary amyloidosis in patients with mycosis fungoides: a rare adverse effect of phototherapy

İtır Ebru ZEMHERİ, Sıdıka Şeyma ÖZKANLI, İlkin ZİNDANCI, Serkan ŞENOL, Özge AKBULAK, Filiz Topaloğlu DEMİR

Liver enzymes, mean platelet volume, and red cell distribution width in gestational diabetes

Serpil ERDOĞAN, Özhan ÖZDEMİR, Halef Okan DOĞAN, Sevilay SEZER, Cemal Reşat ATALAY, Fatma Meriç YILMAZ, Yüksel KOCA

Comparison of the effects of different percutaneous tracheotomy techniques on acute tracheal trauma

Cengiz Bekir DEMİREL, Hacer HALTAŞ, Hasan Kutluk PAMPAL, Yusuf ÜNAL, Berrin IŞIK, Mükerrem UYSAL