Usage of spline interpolation in catheter-based cardiac mapping

Due to their minimal invasiveness catheters are highly preferred in cardiac mapping techniques used in the source localization of rhythm disturbances in the heart. In cardiac mapping, standard steerable catheters and multielectrode basket catheters are the two alternatives for the characterization of the underlying tissue on the inner (endocardium) and outer (epicardium) surfaces of the heart. As with any discrete sampling technique, an important question for catheter-based cardiac mapping is how to determine values at locations from which direct measurements are not available. Interpolation is the most common approach for providing values at unmeasured sites using the available measurements. In this study, the usage of spline interpolation technique in catheter-based cardiac mapping was introduced for the first time in the literature and compared with the existing approaches such as the nearest-neighbor, Laplacian, and Hardy's interpolation techniques. For different sampling resolutions on the endocardium and epicardium, we reconstructed the activation-time values on unmeasured sites using measured values. To provide quantitative validation, we have applied these methods to high resolution simulated activation-time values from a realistic heart model using Aliev-Panfilov mathematical modeling approach. The results show that spline, Laplacian, and Hardy interpolation methods performed successfully and also better than nearest-neighbor method. Among all interpolation schemes except for the nearest-neighbor method the average correlation coefficient (CC) values were greater than 0.985.

Usage of spline interpolation in catheter-based cardiac mapping

Due to their minimal invasiveness catheters are highly preferred in cardiac mapping techniques used in the source localization of rhythm disturbances in the heart. In cardiac mapping, standard steerable catheters and multielectrode basket catheters are the two alternatives for the characterization of the underlying tissue on the inner (endocardium) and outer (epicardium) surfaces of the heart. As with any discrete sampling technique, an important question for catheter-based cardiac mapping is how to determine values at locations from which direct measurements are not available. Interpolation is the most common approach for providing values at unmeasured sites using the available measurements. In this study, the usage of spline interpolation technique in catheter-based cardiac mapping was introduced for the first time in the literature and compared with the existing approaches such as the nearest-neighbor, Laplacian, and Hardy's interpolation techniques. For different sampling resolutions on the endocardium and epicardium, we reconstructed the activation-time values on unmeasured sites using measured values. To provide quantitative validation, we have applied these methods to high resolution simulated activation-time values from a realistic heart model using Aliev-Panfilov mathematical modeling approach. The results show that spline, Laplacian, and Hardy interpolation methods performed successfully and also better than nearest-neighbor method. Among all interpolation schemes except for the nearest-neighbor method the average correlation coefficient (CC) values were greater than 0.985.

___

  • M.D. Lesh, G.F. Van Hare, L.M. Epstein, A.P. Fitzpatrick, M.N. Scheinman, R.J. Lee, M.A. Kwasman, H.R. Grogin, J.C. Griffin, “Radiofrequency catheter ablation of atrial arrhythmias. Results and mechanisms”. Circulation, Vol. 89(3), pp. 1074-1089, 1994.
  • D. Darbar, J.E. Olgin, J.M. Miller, P. Friedman, “Localization of the origin of arrhythmias for ablation: From electrocardiography to advanced endocardial mapping systems”, J. Cardiovasc. Electrophysiol., Vol. 12(4), pp. 1309–1325, 2001.
  • L. Gepstein, G. Hayam, S.A. Ben-Haim, “A novel method for nonfluoroscopic catheter-based electroanatomical mapping of the heart. In vitro and in vivo accuracy results”, Circulation, Vol. 95(1), pp. 1611-1622, 1997.
  • N.M.S. de Groot, M. Bootsma, E.T. van der Velde, M.J. Schalij, “Three-dimensional catheter positioning during radiofrequency ablation in patients: First application of a real-time position management system”, J. Cardiovasc. Electrophysiol., Vol. 11, pp. 1183–1192, 2000.
  • M. Eldar, D.G. Ohad, J.J. Goldberger, Z. Rotstein, S. Hsu, D.K. Swanson, A.J. Greenspon, “Transcutaneous mul- tielectrode basket catheter for endocardial mapping and ablation of ventricular tachycardia in the pig”, Circulation, Vol. 96, pp. 2340–2437, 1997.
  • G. Arisi, E. Macchi, S. Baruffi, S. Spaggiari, B. Taccardi, “Potential Şelds on the ventricular surface of the exposed dog heart during normal excitation”, Circulation Research, Vol. 52, pp. 706-715, 1983.
  • S.M. Blanchard, R.J. Damiano Jr, W.M. Smith, R.E. Ideker, J.E. Lowe, “Interpolating unipolar epicardial potentials from electrodes separated by increasing distances”, PACE, Vol. 12, pp. 1938-1955, 1989.
  • R.L. Hardy, “Theory and applications of the multiquadric-biharmonic method”, Computers Math. Applic., Vol. 19(8/9), pp. 163-208, 1990.
  • A. van Oosterom, T.F. Oostendorp, G.J. Huiskamp, “Interpolation on a triangulated 3D surface”, J Comp Phys., Vol. 80, pp. 331–343, 1989.
  • R.O. Kuenzler, Generating Epicardial Activation Order from Multielectrode Venous Catheters. M.S. Thesis, Univ. Utah, Salt Lake City, 1998.
  • Q. Ni, R.S. MacLeod, R.L. Lux, B. Taccardi, “A Novel interpolation method for electrical Şelds in the heart during excitation”, Annals of Biomed. Eng., Vol. 26, pp. 597-607, 1998.
  • R. Hoekema, The Interindividual Variability of the Electrocardiogram, Ph.D. Thesis, Katholieke Universiteit, Nijmegen, 1999.
  • G. Wahba, “Spline interpolation and smoothing on the sphere”, SIAM J. Sci. Stat. Comp., Vol. 2(1), pp. 5-16, 1981. [14] F. Perrin, J. Pernier, O. Bertrand, J.F. Echallier, “Spherical splines for scalp potential and current density mapping”, Electroencephalogr. Clin. Neurophysiol., Vol. 72, pp. 184-187, 1989.
  • S.K. Law, P.L. Nunez, R.S. Wijesinghe, “High-resolution EEG using spline generated surface Laplacians on spherical and ellipsoidal surfaces”, IEEE Trans. Biomed. Eng., Vol. 40, pp. 145-153, 1993.
  • R. Srinivasan, P.L. Nunez, D.M. Tucker, R.B. Silberstein, P.J. Kadusch, “Spatial sampling and Şltering of EEG with spline Laplacians to estimate cortical potentials”, Brain Topogr., Vol. 8, pp. 355-366, 1996.
  • R.N. Ghanem, C. Ramanathan, J. Ping, Y. Rudy, “Heart-surface reconstruction and ECG electrodes localization using fluoroscopy, epipolar geometry and stereovision: Application to noninvasive imaging of cardiac electrical activity”, IEEE Trans. Med. Imag., Vol. 22(4), pp. 1307-1318, 2003.
  • M.J. Moulton, L.L. Creswell, S.W. Downing, R.L. Actis, B.A. Szabo, M.W. Vannier, M.K. Pasque, “Spline surface interpolation for calculating 3-D ventricular strains from MRI tissue tagging”, Am J Physiol Heart Circ Physiol, Vol. 270, pp. H281-H297, 1996.
  • J.E. Burnes, D.C. Kaelber, B. Taccardi, R.L. Lux, P.R. Ershler, Y. Rudy, “A Şeld-compatible method for interpo- lating biopotentials”, Annals of Biomed. Eng., Vol. 26(1), pp. 37-47, 1998.
  • R.R. Aliev, A.V. PanŞlov, “A simple two-variable model of cardiac excitation”, Chaos, Solitons and Fractals, Vol. 7(3), pp. 293-301, 1996.
  • A.V. PanŞlov, J.P. Keener, “Re-entry in anatomical model of the heart”, Chaos, Solitons and Fractals, Vol. 5, pp. 681-689, 1995.
  • K.H.W.J. ten Tusscher, O. Bernus, R. Hren, A.V. PanŞlov, “Comparison of electrophysiological models for human ventricular cells and tissues”, Prog. in Biophysics and Mol. Biol., Vol. 90, pp. 326-345, 2006.
  • U. Cunedioglu, B. Yilmaz, “Combination of computer simulations and experimental measurements as the training dataset for statistical estimation of epicardial activation maps from venous catheter recordings”, IEEE Trans. Biomed. Eng., Vol. 56(3), pp. 837-845, 2009.
  • P.M.F. Nielsen, I.J. LeGrice, B.H. Smail, P.J. Hunter, “A mathematical model of the geometry and Şbrous the heart”, Am. J. Physiol., Vol. 260, pp. H1365–1378, 1991.
  • M.T. Heath, ScientiŞc Computing, An Introductory Survey, McGraw-Hill, New York, 1997.
  • L. Soufflet, M. Toussaint, R. Luthringer, J. Gresser, R. Minot, J.P. Macher, “A statistical evaluation of the main interpolation methods applied to 3-dimensional EEG mapping”, Electroencephalogr. Clin. Neurophysiol., Vol. 79, pp. 393-402, 1991.
  • A.C. Soong, J.C. Lind, G.R. Shaw, Z.J. Koles, “Systematic comparisons of interpolating techniques in topographic brain mapping”, Electroencephalogr. Clin. Neurophysiol., Vol. 87, pp. 185-195, 1993.
  • B. Yılmaz, Venous Catheter Based Mapping of Epicardial Ectopic Activation Using Statistical Estimation, PhD Thesis, University of Utah, Salt Lake City, Utah, 2004.
  • W. Kaltenbrunner, R. Cardinal, M. Dubuc, M. Shenasa, R. Nadeau, G. Tremblay, M. Vermeulen, P. Savard, P. Page, “Epicardial and endocardial mapping of ventricular tachyarrhythmia in patients with myocardial infarction. Is the origin of the tachycardia always subendocardially localized?”, Circulation, Vol. 84, pp. 1058–1071, 1991.