Biomedical Circuits and Systems Dedicated for Sensing and Neurostimulation: Case study on Urinary Bladder dysfunctions

This paper covers circuits and systems techniques for the construction of high reliability biosensing and neurostimulation smart medical devices. Such microsystems are dedicated for interconnections through the peripheral neural systems. Case study related to applications such as bladder control is discussed. Available electrical neurostimulation techniques for the rehabilitation of urinary bladder functions do not allow an adequate voiding due to dyssynergia between the bladder and the sphincter. A new implantable stimulator, built with commercially available electronic components, was designed to overcome these difficulties. The proposed system performs two types of stimulations: Selective Stimulation for bladder voiding and Permanent Stimulation to reduce the bladder overactivity symptoms. Also, a fully integrated extended version of the stimulator is achieved with the additional ability to monitor the electrodes-nerve contact impedance variations in order to detect electrodes faults or nerve physiology changes. The implemented full custom device provides a reliable stimulation technique and addresses the lack of features (programmable parameters, user-friendly interface and waveform flexibility) of the previous stimulation devices. Experimental results of the fabricated chip confirm its functionality. The microstimulator generates a wide range of stimuli waveforms with variable parameters and its modular architecture makes it an expandable multichannel stimulation system.

Biomedical Circuits and Systems Dedicated for Sensing and Neurostimulation: Case study on Urinary Bladder dysfunctions

This paper covers circuits and systems techniques for the construction of high reliability biosensing and neurostimulation smart medical devices. Such microsystems are dedicated for interconnections through the peripheral neural systems. Case study related to applications such as bladder control is discussed. Available electrical neurostimulation techniques for the rehabilitation of urinary bladder functions do not allow an adequate voiding due to dyssynergia between the bladder and the sphincter. A new implantable stimulator, built with commercially available electronic components, was designed to overcome these difficulties. The proposed system performs two types of stimulations: Selective Stimulation for bladder voiding and Permanent Stimulation to reduce the bladder overactivity symptoms. Also, a fully integrated extended version of the stimulator is achieved with the additional ability to monitor the electrodes-nerve contact impedance variations in order to detect electrodes faults or nerve physiology changes. The implemented full custom device provides a reliable stimulation technique and addresses the lack of features (programmable parameters, user-friendly interface and waveform flexibility) of the previous stimulation devices. Experimental results of the fabricated chip confirm its functionality. The microstimulator generates a wide range of stimuli waveforms with variable parameters and its modular architecture makes it an expandable multichannel stimulation system.

___

  • M. Sawan, Y. Hu, J. Coulombe, “Wireless Smart Implants Dedicated to Multichannel Monitoring and Micros- timulation”, Invited paper in IEEE Circuits and Systems Magazine, Vol. 5, pp. 21-39, 2005.
  • J. Coulombe, M. Sawan, J. F. Gervais, “A Highly Flexible System for Microstimulation of the Visual Cortex: Design and Implementation”, IEEE Trans. on Biomedical Circuits & Systems, Vol. 1, No. 4, pp. 258-269, December 2007.
  • M. Sawan, “Biomedical Circuits and Systems Dedicated for Sensing and Neurostimulation”, Lecture at ELECO, Bursa, Turkey, Dec. 2007.
  • D. Buback, “The use of neuromodulation for treatment of urinary incontinence”, AORN Journal, 73:176-190, 2001.
  • J. Walter, R. Sidarous, C. J. Robinson, J. S. Wheeler, R. D. Wurster, “Comparison of direct bladder and sacral nerve stimulation in spinal cats”, Journal of Rehab. Res. and Dev., 29, 2:13-22, 1992.
  • J. P. Heine, R. A. Schmidt, E. A. Tanagho, “Intraspinal sacral root stimulation for controlled micturition”, Invest. Urol.,15:78, 1977.
  • W. E. Bradley, G. W. Timm, S. N. Chou, “A decade of experience with electronic stimulation of the micturition reflex”, Urol. Int., 26:283, 1971.
  • H. N. Habib, “Experience and recent contributions in sacral nerve stimulation for both human and animal”, Br. J. Urol., 39:73, 1967.
  • R. A. Schmidt, H. Bruschini, E. A. Tanagho, “Urinary bladder and sphincter responses to stimulation of dorsal and ventral sacral roots”, Invest. Urol, 16:300, 1979.
  • A. S. Haleem, F. Boehm, A. D. Legatt, A. Kantrowitz, B. Stone, A. Melman, “Sacral root stimulation for controlled micturition: Prevention of detrusor-external sphincter dyssynergia by intraoperative identiŞcation and selective section of sacral nerve branches”, Journal of Urol, 149:1607-1612, 1993.
  • A. Tallala, J. W. Bloom, N. Quang, “FES for Bladder: Direct or indirect Means? ”, PACE, 10:240-245, 1987. [12] N. J. M. Rijkhoff, H. Wikstra, P. E. V. Van Kerrebroeck, F.M.J. Debruyne, “Urinary bladder control by electrical stimulation: review of electrical stimulation techniques in spinal cord injury”, Neurourol. Urodynam, 16:39-53, 1997.
  • B. Holmquist, W.J. Staubitz, “The role of the pudendal nerve in connections with electronic emptying of the neurogenic cord bladder in dogs”, Journal of Urol., 91:41-54, 1964.
  • B. S. Nashold, H. Friedman, J. H. Glen, J. H. Grimes, W. F. Barry, R. Avery, “Electromicturition in paraplegia”, Arch. Surg., 104:195, 1972.
  • H. Friedman, B. S. Jr. Nashold, J. Grimes, “Electrical Stimulation of the Conus Medullaris in the paraplegic - A Şve year review”, In FT hambrecht, JB Reswick (eds): Functionnal electrical stimulation, New York and Basel: Marcel Dekker, Inc, 173, 1977.
  • G. S. Brindley, C. S. Polkey, D. N. Rushton, “Sacral anterior root stimulators for bladder control in paraplegia”, Paraplegia, 20:365, 1982.
  • G. S. Brindley “An implant to empty the bladder or close the urethra”, Journal of Neurology, Neurosurgery, and Psychiatry, 40:358-369, 1977.
  • J. S. Li, M. Hassouna, M. Sawan, F. Duval, M. M. Elhilali, “Long-term effect of sphincteric fatigue during bladder neurostimulation”, The journal of Urol., 153:238-242, 1995.
  • M. Sawan, M. Hassouna, J. S. Li, F. Duval, M. M. Elhilali, “Stimulator design and subsequent stimulation parameter optimization for controlling micturition and reducing urethral resistance”, IEEE Transactions on Rehabilitation Engineering, 4, 1:39-46, 1996.
  • J. D. Sweeney, J. T. Mortimer, D. R. Bodner, “Acute animal studies on electrically induced collision block of pudendal nerve motor activities”, Neurourolog. Urodyn., 8:521, 1989.
  • G. S. Brindley, M. D. Craggs, “A technique for anodally blocking large nerve Şbers through chronically implanted electrodes, ” J. Neurol. Neurosurg. Psychiatry, 1980, 43:1083.
  • E. L. Koldewijn, N. J. Rijkhoff, Ph. E. V. Van Kerrebroeck, F. M. J. Debreyne, H. Wijkstra, “Selective sacral root stimulation for bladder control: Acute experiments in a animal model”, Journal of Urol., 151:1674, 1992. [23] M. Ishigooka, T. Hashimoto, I. Sasagawa, K. Izumiya, T. Nakada, “Modulation of the urethral pressure by high-frequency block stimulus in dogs”, Eur. Urol., 25:334, 1994.
  • H. S. Shaker, L. M. Tu, S. Robin, K. Arabi, M. Hassouna, M. Sawan, M. M. Elhilali, “Reduction of bladder outlet resistance by selective sacral root stimulation using high-frequency blockade in dogs : An acute study”, The Journal of Urol., Vol. 160: 901-907, 1998.
  • N. Accornero, G. Bini, G. L. Lenzi, M. Manfredi, “Selective activation of peripheral nerve Şber groups of different diameter by triangular shaped stimulus pulses”, Journal Physiol., 273:539-560, 1977.
  • Z. P. Fang, J. T. Mortimer, “Selective activation of small motor axons by quasitrapezoidal current pulses”, IEEE Trans. Biomed. Eng., 38:168-174, 1991.
  • S. Robin, M. Sawan, M. Abdel-Gawad, T.M. Abdel-Baky, M.M. Elhilali, “Implantable stimulation system dedicated for neural selective stimulation”, Medical & Biological Engineering & Computing Vol. 36, No. 4, pp. 490-492, 1998.
  • P. Magasi, Z. Simon, “Electrical stimulation of the bladder and gravidity”, Urology International, No. 41:241- 245, 1986.
  • T. A. Perkins, “Versatile Three-channel stimulation controller for restoration of bladder functions in paraplegia”, Journal of Biomed. Eng., Vol. 8:268-271, 1986.
  • ——-, “Interstim therapy for urinary control”, Medtronic Neurological Inc., Minneapolis, 1999.
  • ——-, “Implantable functional neuromuscular stimulator”, Vocare bladder system, Neurocontrol Corporation, Ohio, 1998.
  • K. Arabi, M. Sawan, “Implantable multiprogrammable microstimulator dedicated to bladder control”, Medical & Biological Engineering & Computing, 34:9-12, 1996.
  • E. Schneider, A. M. Abdel-Karim, M. Sawan, M. M. Elhilali, “New stimulation strategy to improve the bladder function in paraplegics: Chronic experiments in dogs”, 23rdIEEE Int. Conf. of Eng. in Medicine and Biology Society, Istanbul, Turkey, 2001.
  • S. Boyer, M. Sawan, M. Abdel-Gawad, S. Robin, M. M. Elhilali, “Implantable selective stimulator improve bladder voiding: design and chronic experiments in dogs”, IEEE Transactions on Rehabilitation Engineering, 8:764-470, 2000.
  • A. Ba, E. Schneider, A. M. Abdel-Karim, M. Sawan, M. M. Elhilali, “Implantable dual stimulator to recuperate the bladder functions: Chronic experiments in dogs”, IFESS, Slovenia, 2002.
  • M. A. Crampon, M. Sawan, V. Brailovski, F. Trochu, “New easy to install nerve cuff electrode using SMA armature”, ArtiŞcial Organs Journal, 23, 5:392-395, 1999.
  • T. Stiegliz, T. Matal, M. Staemmler, “A modular multichannel stimulator for arbitrary shaped current pulses for experimental and clinical use in FES”, Proceedings of the 19th International Conference IEEE/EMBS, Illinois, 1997.
  • C. Donfack, M. Sawan, Y. Savaria, “An implantable measurement technique dedicated to the monitoring of electrodes-nerve contact in bladder stimulators”, Medical & Biological Engineering & Computing, 38:465-568, 2000.