Evaporative Cooling Efficiency of a Fogging System for Greenhouses

The objective of this study was to investigate the efficiency of fogging system (FS) for greenhouses. The experiments were carried out in a multi-span plastic greenhouse (PG), 105.6 m wide and 205 m long, made of 11 spans. The FS consists of a water softener and filters to prevent nozzle clogging, a water reservoir, pumps and a pressure regulator, and fog generating nozzles (FGN). The required pressure for FGN was 4.5 atm. Three nozzle lines with 82 FGN were installed in each span of the PG. At each nozzle line, 82 FGN were uniformly located at 2.5 m nozzle spacing. The FGN parameters were determined in order to characterize the efficiency of the FS based on air flow rate (AFR) and evaporation flow rate (EFR). The results showed that the FS was able to keep the air temperature inside the PG 6.6 oC lower than the outside. The average ventilation rate of the PG was 13.64 m3 s-1 during the experimental period. The efficiency of the FS ranged from 11.7% to 80%. The efficiency of the FS increased as the difference between the dry-bulb temperature (DBT) and wet-bulb temperature (WBT) rose. The results indicated that air relative humidity (RH) inside the PG was increased by 25% on average by means of the FS examined in this study. The EFR varied between 130.3 g m-2 h-1 and 1223.4 g m-2 h-1, while the AFR ranged from 39.3 kg m-2 h-1 to 298.7 kg m-2 h-1. Fogging system efficiency (FSE) increased linearly with EFR and absolute humidity difference (AHD) between the inside and outside air.

Evaporative Cooling Efficiency of a Fogging System for Greenhouses

The objective of this study was to investigate the efficiency of fogging system (FS) for greenhouses. The experiments were carried out in a multi-span plastic greenhouse (PG), 105.6 m wide and 205 m long, made of 11 spans. The FS consists of a water softener and filters to prevent nozzle clogging, a water reservoir, pumps and a pressure regulator, and fog generating nozzles (FGN). The required pressure for FGN was 4.5 atm. Three nozzle lines with 82 FGN were installed in each span of the PG. At each nozzle line, 82 FGN were uniformly located at 2.5 m nozzle spacing. The FGN parameters were determined in order to characterize the efficiency of the FS based on air flow rate (AFR) and evaporation flow rate (EFR). The results showed that the FS was able to keep the air temperature inside the PG 6.6 oC lower than the outside. The average ventilation rate of the PG was 13.64 m3 s-1 during the experimental period. The efficiency of the FS ranged from 11.7% to 80%. The efficiency of the FS increased as the difference between the dry-bulb temperature (DBT) and wet-bulb temperature (WBT) rose. The results indicated that air relative humidity (RH) inside the PG was increased by 25% on average by means of the FS examined in this study. The EFR varied between 130.3 g m-2 h-1 and 1223.4 g m-2 h-1, while the AFR ranged from 39.3 kg m-2 h-1 to 298.7 kg m-2 h-1. Fogging system efficiency (FSE) increased linearly with EFR and absolute humidity difference (AHD) between the inside and outside air.
Turkish Journal of Agriculture and Forestry-Cover
  • ISSN: 1300-011X
  • Yayın Aralığı: Yılda 6 Sayı
  • Yayıncı: TÜBİTAK
Sayıdaki Diğer Makaleler

The reaction of crotonic anhydride with scots and corsican pine investigation of kinetic profiles and determination of activation energies

Nilgül ÖZMEN, Nihat Sami ÇETİN

Effect of Indole-3-Butyric Acid and Different Strains of Agrobacterium rubi on Adventive Root Formation from Softwood and Semi-Hardwood Wild Sour Cherry Cuttings

Ahmet EŞİTKEN

Effects of Plant Density and Number of Shoots on Yield and Fruit Characteristics of Peppers Grown in Glasshouses

H. Yıldız DAŞGAN, Kazım ABAK

Estimation of the Effect of Soil Salinity on Crop Yield Using Remote Sensing and Geographic Information System

Mehmet Ali ÇULLU

Population Densities of Liriomyza huidobrensis (Blanchard, 1926) (Diptera: Agromyzidae) in Insecticide-Treated and Non-Treated Cucumber Producing Greenhouses in the İzmir Region

Hasan Sungur CİVELEK

Population densities of Liriomyza huidobrensis (Blanchard, 1926) (Diptera: Agromyzidae) in insecticide-treated and non-treated cucumber producing greenhouses in he İzmir Region

Hasan Sungur CİVELEK, Zeynep YOLDAŞ

Effects of plant density and number of shoots on yield and fruit chcracteristics of peppers grown in glasshouses

H. Yıldız DAŞGAN, Kazım ABAK

Evaluation of land use potential and suitability of ecosystems in Antakya for reforestation, recreation, arable farming and residence

Şeref KILIÇ, Suat ŞENOL, Fatih EVRENDİLEK

Antakya Ekosistemlerinin A¤açland›rma, Rekreasyon, Tar›m ve Konut için Arazi Kullan›m Potansiyeli ve Uygunlu¤unun De¤erlendirilmesi

Şeref KILIÇ

Comparative Study of Wood Density by Specific Amount of Void Volume (Porosity)

İlker USTA