The effect of posterior capsulotomy size on refraction and anterior chamber parameters following Nd:YAG laser treatment

To investigate the effect of capsulotomy size on refraction and anterior chamber parameters following Nd:YAG laser treatment. Fifty-six eyes of 56 pseudophakic patients with posterior capsular opacification (PCO) were reviewed. Patients were divided into two groups according to the capsulotomy size. Changes in best corrected visual acuity (BCVA), spherical equivalent (SE), anterior chamber depth (ACD), anterior chamber volume (ACV) and anterior chamber angle (ACA) were compared between groups. A hyperopic shift was remarkable in the 1st week in both groups but SE declined about to preoperative levels at 1 month after laser capsulotomy in both groups (p=0,056). In both groups, ACD decreased 1 week after laser capsulotomy (p

___

Varga A, Sacu S, Vécsei-Marlovits PV, et al. Effect of posterior capsule opacification on macular sensitivity. J Cataract Refract Surg. 2008;34:52-6.

MacEwen CJ, Dutton GN. Neodymium-YAG Laser in the management of posterior capsular opacification: complications and current trends. Trans Ophthalmol Soc UK. 1986;105:337-44.

Apple DJ, Solomon KD, Tetz MR, et al. Posterior capsule opacification. Surv Ophthalmol. 1992;37:73-116. 4. Zaidi M, Askari SN. Effect of Nd:YAG laser posterior capsulotomy on anterior chamber depth, intraocular pressure and refractive status. Asian J Ophthalmol. 2004;5:2-5.

Wormstone IM, Wang L, Liu CS. Posterior capsule opacification. Exp Eye Res. 2008;88:257-69.

Hu CY, Woung LC, Wang MC. Change in the area of laser posterior capsulotomy: 3-month follow-up. J Cataract Refract Surg. 2001;27:537-42.

Hu CY, Woung LC, Wang MC, et al. Influence of laser posterior capsulotomy on anterior chamber depth, refraction, and intraocular pressure. J Cataract Refract Surg. 2000;26:1183-9.

Gore VS. The study of complications of Nd-YAG laser capsulotomy. Int J Bioinform Res. 2012;4:265-8.

Findl O, Drexler W, Menapace R, et al. Changes in intraocular lens position after neodynamium:YAG capsulotomy. J Cataract Refract Surg. 1999;25:65962. 10. Chua CN, Gibson A, Kazakos DC. Refractive changes following Nd:YAG capsulotomy. Eye. 2001;15:304-5.

Ozkurt YB, Sengör T, Evciman T, et al. Refraction, intraocular pressure and anterior chamber depth changes after Nd:YAG laser treatment for posterior capsular opacification in pseudophakic eyes. Clin Exp Optom. 2009;92:4125.

Smith RT, Moscoso WE, Trokel S, et al. The barrier function in neodymiumYAG laser capsulotomy. Arch Ophthalmol. 1995;113:645-52.

Thornval P, Naeser K. Refraction and anterior chamber depth before and after neodymium: YAG laser treatment for posterior capsule opacification in pseudophakic eyes: a prospective study. J Cataract Refract Surg. 1995;21:45760.

Meena Z, Saiyid NA. Effect of Nd:YAG capsulotomy on anterior chamber depth, intraocular pressure and refractive status. Asian J Ophthalmol 2004;5:2-5.

Cetinkaya S, Cetinkaya YF, Yener HI, et al. The influence of size and shape of Nd:YAG capsulotomy on visual acuity and refraction. Arq Bras Oftalmol. 2015;78(4):220-3.

Hayashi K, Nakao F, Hayashi H. Influence of size of neodymium:yttriumaluminium-garnet laser posterior capsulotomy on visual function. Eye. 2010;24:101-6.

Alimanovic Halilovic E. Correlation between eye aperture diameter and complications in the posterior eye segment after Nd-YAG capsulotomy. Bosn J Basic Med Sci. 2008;8:106-9.

Yilmaz S, Ozdil MA, Bozkir N, et al The effect of Nd:YAG laser capsulotomy size on refraction and visual acuity. J Refractive Surg. 2006;22:719-21.

Karahan E, Tuncer I, Zengin MO. The Effect of ND:YAG Laser Posterior Capsulotomy Size on Refraction, Intraocular Pressure, and Macular Thickness. J Ophthamol. 2014;2014:846385.

Nakazawa M, Ohtsuki K. Apparent accommodation in pseudophakic eyes after implantation of posterior chamber intraocular lenses. Am J Ophthamol. 1983;96:435-8.
Medicine Science-Cover
  • ISSN: 2147-0634
  • Yayın Aralığı: Yılda 4 Sayı
  • Başlangıç: 2012
  • Yayıncı: Effect Publishing Agency ( EPA )