DEVELOPMENT OF PASSIVE ENERGY SOURCE AS EARTH AIR PIPE HEAT EXCHANGERS (EAPHE) SYSTEM -A REVIEW

DEVELOPMENT OF PASSIVE ENERGY SOURCE AS EARTH AIR PIPE HEAT EXCHANGERS (EAPHE) SYSTEM -A REVIEW

Diversity in living standards and population growth leads to increased global energy consumption.Human comfort always plays a vital role in using different means to reduce the effects of weather conditions. Thebuilding sector captures approximately 40% of the global energy and it is most commonly used for cooling and forheating of the space occupied due to the use of appliances such as room heaters or air coolers, air conditioners, etc.The use of these appliances contributes significantly to global warming, which is a very serious environmentalproblem. Passive energy sources are used widely to reduce the consumption of energy due to heating and cooling ofthe building. Earth air pipe heat exchanger is one of the passive cooling/ heating technology used for the indoorthermal comfort of the occupants. In this review article, various discussion has been done on the use of passive energyexplained by the earth air pipe heat exchanger and various investigations conducted by authors under differentconditions and parameters like air velocity, pipe depth, pipe length, etc. that the thermal conductivity of the soil is thekey point to the efficient operation of the earth air pipe heat exchanger system and it is also necessary to maintain thethermal conductivity of the soil in the vicinity of the pipe in order to achieve better performance in operation

___

  • [1] Introduction to national rating system:GRIHA Manual.
  • [2] Nejat P, Jomehzadeh F, Taheri MM, Gohari M, Majid MZA. A global review of energy consumption, {CO2} emissions and policy in the residential sector (with an overview of the top ten {CO2} emitting countries). Renew Sustain Energy Rev2015;43:843–62.
  • [3] Jacovides C, Mihalakakou G, Santamouris M, Lewis J. On the ground temperature profile for passive cooling applications in buildings. Sol Energy 1996;57(3):167–75.
  • [4] Mihalakakou G, Santamouris M, Asimakopoulos D. Modelling the thermal performance of earth-to-air heat exchangers. Sol Energy 1994;53(3):301–5.
  • [5] Sawhney R, Buddhi D, Thanu N. An experimental study of summer performance of a recirculation type underground air pipe air conditioning system. Build Environ 1999;34:189–96.
  • [6] Vaz J, Sattler MA, dos Santos ED, Isoldi LA. Experimental and numerical analysis of an earthair heat exchanger. Energy Build 2011;43(9):247682
  • [7] Jayashankar BC, Sawhney RL, Sodha MS. Effect of different surface treatments of the surrounding earth on thermal performance of earth- integrated buildings. Int JEnergy Res 1989;13:605–19.
  • [8] Givoni B, Katz L. Earth temperatures and underground buildings. Energy Build 1985;8(1):15–25.
  • [9] Omer AM. Ground-source heat pumps systems and applications. Renew Sustain Energy Rev 2008;12(2):344–71.
  • [10] Esen H, Inalli M, Esen M. Numerical and experimental analysis of a horizontal ground-coupled heat pump system. Build Environ 2007;42(3):1126–34.
  • [11] Givoni B. Earth-integrated buildingsan overview. Archit Sci Rev1981;24(2):42–53,
  • [12] Deshmukh MK, Sodha MS, Sawhney RL. Effect of depth of sinking on thermal performance of partially underground building. Int J Energy Res 1991;15(5):391–403, 〈http://dx.doi.org/10.1002/er.4440150506〉.
  • [13] Esen H, Esen M, Ozsolak O. Modelling and experimental performance analysis of solar-assisted ground source heat pump system. J Exp Theor Artif Intell 2017;29(1):1–17,
  • [14] Lucia U, Simonetti M, Chiesa G, Grisolia G. Ground-source pump system for heating and cooling: review and thermodynamic approach. Renew Sustain Energy Rev 2017;70:867–74.
  • [15] Inalli M, Esen H. Experimental thermal performance evaluation of a horizontal ground-source heat pump system. Appl Therm Eng 2004;24(1415):2219–2232.
  • [16] Wu W, You T, Wang B, Shi W, Li X. Simulation of a combined heating, cooling and domestic hot water system based on ground source absorption heat pump. Appl Energy 2014;126:113–22.
  • [17] Balbay A, Esen M. Experimental investigation of using ground source heat pump system for snow melting on pavements and bridge decks. Sci Res Essay 2010;5(24):3955–66.
  • [18] Balbay A, Esen M. Temperature distributions in pavement and bridge slabs heated by using vertical ground-source heat pump systems. Acta Sci-Technol 2013;35(4):677–85.
  • [19] Esen H, Inalli M, Esen M. A techno-economic comparison of ground-coupled and air-coupled heat pump system for space cooling. Build Environ 2007;42(5):1955–65.
  • [20] Khatry AK, Sodha MS, Malik MAS. Periodic variation of ground temperature with depth. Sol Energy 1978;20:425– 7.
  • [21] Wu H, Wang S, Zhu D. Modelling and evaluation of cooling capacity of earthairpipe systems. Energy Convers Manag 2007;48:1462–71.
  • [22] Ozgener L. A review on the experimental and analytical analysis of earth to air heat exchanger (eahe) systems in turkey. Renew Sustain Energy Rev 2011;15:4483–90.
  • [23] Trilok Singh Bisoniya PB, Kumar Anil. Experimental and analytical studies of earthair heat exchanger (eahe) systems in india: a review. Renew Sustain Energy Rev 2013;19:238–46.
  • [24] Clara Peretti MDCRZ, Zarrella Angelo. The design and environmental evaluation of earth-to-air heat exchangers(eahe).a literature review. Renew Sustain Energy Rev 2013;28:107–16.
  • [25] Kaushal M. Geothermal cooling/heating using ground heat exchanger for various experimental and analytical studies: comprehensive review. Energy Build 2017;139:634–52.
  • [26] Bayareh M. and Nourbakhsh A., Numerical simulation and analysis of heat transfer for different geometries of corrugated tubes in a double pipe heat exchanger. Journal of thermal engineering 2019;5(4); 293-301.
  • [27] Keklikcioglu O., Dagdevir T and Ozceyhan V. A CFD based thermo-hydraulic performance analysis in a tube fitted with stepped conical nozzle turbulators. Journal of thermal engineering 2016;2(5);913-920.
  • [28] Hourmanesh M, Ray H, Elmer DB, Earth air heat exchanger system, In: Prowler D, ed., Proc. 2nd National Passive Solar Conference (March 16–19, 1978)Philadelphia, PA. Newark, DE: American Section of ISES.
  • [29] Thoburn W. Performance of earth-air tunnel system, Private communication.
  • [30] Sodha M, Sharma A, Singh S, Bansal N, Kumar A. Evaluation of an earth air tunnel system for cooling/heating of a hospital complex. Build Environ1985;20(2):115–22.
  • [31] Bansal NK, Sodha MS. An earth-air tunnel system for cooling buildings. Tunn Undergr Space Technol 1986;1(2):177– 82.
  • [32] Akridge J. Investigation of passive cooling techniques for hot humid climates, Research report, College of Architecture, Georgia Institute of Technology, Atlanta, Georgia.
  • [33] Bansal N, Sodha MS, Bharadwaj SS. Performance of earth-air tunnels. Energy Res 1983;7:333.
  • [34] Mihalakakou G, Santamouris M, Asimakopoulos D. On the cooling potential of earth to air heat exchangers. Energy Convers Manag 1994;35(5):395–402.
  • [35] Zhang Q, Ishihara O, Hayashi T. Development of residence with solar heating earth cooling, and air circulation. ASHRAE Trans 1994:333–41.
  • [36] Ishihara O, Zhang Q. Cooling effects of earth tubes on dwellings. In: Proceedings of the 1992 ASME/JSES/KSES international solar energy conference.
  • [37] Thanu N, Sawhney R, Khare R, Buddhi D. An experimental study of the thermal performance of an earth-air-pipe system in single pass mode. Sol Energy 2001;71(6):353–64.
  • [38] Kumar R, Ramesh S, Kaushik S. Performance evaluation and energy conservation potential of earthairtunnel system coupled with non-air-conditioned building. Build Environ 2003;38:807–13.
  • [39] Chel A, Tiwari GN. Performance evaluation and life cycle cost analysis of earth to air heat exchanger integrated with adobe building for new delhi composite climate.Energy Build 2009;41:56–66.
  • [40] Al-Ajmi F, Loveday D, Hanby V. The cooling potential of earth air heat exchangers for domestic building in a desert climate. Build Environ 2006;41:235–44.
  • [41] Bojic M, Trifunovic N, Papadakis G, Kytitsis S. Numerical simulation, technical and economic evaluation of air-toearth heat exchanger coupled to a building. Energy 1997;22:1151–8.
  • [42] Saifi N, Settou N, Dokkar A. Modeling and parametric studies for thermal performance of an earth to air heat exchanger in south east algeria. In: IREC2015The Sixth International Renewable Energy Congress, 2015, pp. 1–6.
  • [43] Wang H, Qi C, Wang E, Zhao J. A case study of underground thermal storage in a solar-ground coupled heat pump system for residential buildings. Renew Energy 2009;34:307–14.
  • [44] Popiel C, Wojtkowiak J, Biernacka B. Measurements of temperature distribution in ground. Exp Therm Fluid Sci 2001;25:301–9.
  • [45] Ghosal M, Tiwari G, Srivastava N, Sodha M. Thermal modelling and experimental validation of ground temperature distribution in greenhouse. Int J Energy Res 2004;28:45–63.
  • [46] Florides G, Kalogirou S. Ground heat exchangers-a review of systems, models and applications. Renew Energy 2007;32:2461–78.
  • [47] Asghar AH, Sharma AK, Singh SP. Effect of different earth surface treatments on sub-soil temperature. Int J Energy Res 1990;14:911–24.
  • [48] Mihalakakou G, Santamouris M, Lewis J, Asimakopoulos D. On the application of the energy equation to predict ground temperature profiles. Sol Energy 1997;60:181–90.
  • [49] Ozgener, Onder & Ozgener, Leyla & Tester, Jefferson. (2013). A practical approach to predict soil temperature variations for geothermal (ground) heat exchangers applications. International Journal of Heat and Mass Transfer. 62. 473-480. 10.1016/j.ijheatmasstransfer.2013.03.031.
  • [50] Kusuda T, Achenbach P. Earth temperature and thermal diffusivity on at selected stations in the united stales. ASHRAE Trans 1965;71:61–75.
  • [51] Kusuda T, Bean W, Annual variation of temperature field and heat transfer under heated ground surface, slab-on grade floor heat loss calculation, Building Science Services 156,
  • [52] Labs K, Ground cooling. In: J. Cook (Ed.), Passive Cooling, MIT Press: Cambridge, MA; 1989. p. 145–196.
  • [53] Bharadwaj S, Bansal N. Temperature distribution inside ground for various surface conditions. Build Environ 1981;16(3):183–92.
  • [54] Mihalakakou G, Santamouris M, Lewis J, Asimakopoulos D. On the application of the energy equation to predict ground temperature profiles. Sol Energy 1997;60:181–90.
  • [55] Derbel HBJ, Kanoun O. Investigation of the ground thermal potential in tunisia focused towards heating and cooling applications. Appl Therm Eng 2010;30:1091–100.
  • [56] Givoni B, Katz L. Earth temperatures and underground buildings. Energy Build 1985;8(1):15–25.
  • [57] Sodha MS, Bansal NK, Seth AK. Variance of the ground temperature distribution. Appl Energy 1981;8:245–54.
  • [58] Baggs S. Remote prediction of ground temperature in australian soils and mapping its distribution. Sol Energy 1983;30:351–66.
  • [59] Krarti M, Lopez-Alonzo C, Claridge D, Kreider J. Analytical model to predict annual soil surface temperature variation. J Sol Energy Eng 1995;117:91–9.
  • [60] Ghosal M, Tiwari G, Srivastava N, Sodha M. Thermal modelling and experimental validation of ground temperature distribution in greenhouse. Int J Energy Res 2004;28:45–63.
  • [61] Bansal N, Sodha MS, Bharadwaj SS. Performance of earth-air tunnels. Energy Res 1983;7:333.
  • [62] Sodha M, Bansal N, Kumar A, Bansal P, Malik M. Solar passive building: science and design, 1st edn. Oxford: Pergamon Press; 1986.
  • [63] de la Flor FS, Domnguez SA. Modelling microclimate in urban environments and assessing its influence on the performance of surrounding buildings. Energy Build 2004;36:403–13.
  • [64] Wang H, Qi C, Wang E, Zhao J. A case study of underground thermal storage in a solar-ground coupled heat pump system for residential buildings. Renew Energy 2009;34:307–14.
  • [65] Khedari J, Permchart W, Pratinthong N, Thepa S, Hirunlabh J. Field study using the ground as a heat sink for the condensing unit of an air conditioner in thailand. Energy 2001;26:797–810.
  • [66] Givoni B. Options and applications of passive cooling. Energy Build 1984;7:297–300.
  • [67] Givoni B. Cooled soil as a cooling source for buildings. Sol Energy 2007;81:316–28.
  • [68] Nassar Y, ElNoaman A, Abutaima A, Yousif S, Salem A. Evaluation of the underground soil thermal storage properties in libya. Renew Energy 2006;31:593–8.
  • [69] Sodha M, Sharma A, Singh S, Bansal N, Kumar A. Evaluation of an earth air tunnel system for cooling/heating of a hospital complex. Build Environ 1985;20(2):115–22.
  • [70] Mathur A, Surana AK, Verma P, Mathur S, Agrawal G, Mathur J. Investigation of soil thermal saturation and recovery under intermittent and continuous operation of eathe. Energy Build 2015;109:291–303.
  • [71] Mihalakakou G, Santamouris M, Asimakopoulos D. On the cooling potential of earth to air heat exchangers. Energy Convers Manag 1994;35(5):395–402.
  • [72] Mihalakakou G, Lewis J, Santamouris M. The influence of different ground covers on the heating potential of earthto-air heat exchangers. Renew Energy 1996;7(1):33–46.
  • [73] Kumar R, Ramesh S, Kaushik S. Performance evaluation and energy conservation potential of earthairtunnel system coupled with non-air-conditioned building. Build Environ 2003;38:807–13.
  • [74] Kabashnikov V, Danilevskii L, Nekrasov V, Vityaz I. Analytical and numerical investigation of the characteristics of a soil heat exchanger for ventilation systems.Int J Heat Mass Transf 2002;45:2407–18.
  • [75] Serageldin AA, Abdelrahman AK, Ookawara S. Earth-air heat exchanger thermal performance in egyptian conditions: experimental results, mathematical model, and computational fluid dynamics simulation. Energy Convers Manag 2016;122:25–38.
  • [76] Santamouris M, Mihalakakou G, Balaras C, Lewis J, Vallindras M, Argiriou A.Energy conservation in greenhouses with buried pipes. Energy 1996;21:353–60.
  • [77] Bojic M, Papadakis G, Kytitsis S. Energy from a two-pipe, earth-to-air heat exchanger. Energy 1999;24:519–23.
  • [78] Bansal V, Misra R, Agrawal GD, Mathur J. Performance analysis of earthpipeair heat exchanger for winter heating. Energy Build 2009;41:1151–4.
  • [79] Benhammou M, Draoui B. Parametric study on thermal performance of earth-to air heat exchanger used for cooling of buildings. Renew Sustain Energy Rev 2015;44:348–55.
  • [80] Belatrache D, Bentouba S, Bourouis M. Numerical analysis of earth air heat exchangers at operating conditions in arid climates. Int. J. Hydrog. Energy 2017;42(13):8898–904.
  • [81] Badescu V. Simple and accurate model for the ground heat exchanger of a passive house. Renew Energy 2007;32:845– 55.
  • [82] Lee KH, Strand RK. The cooling and heating potential of an earth tube system in buildings. Energy Build 2008;40:486– 94.
  • [83] Wu H, Wang S, Zhu D. Modelling and evaluation of cooling capacity of earth air pipe systems. Energy Convers Manag 2007;48:1462–71.
  • [84] Sodha MS, Mahajan U, Sawhney RL. Thermal performance of a parallel earth air pipes system. Int J Energy Res 1994;18:437–77.
  • [85] Yoon G, Tanaka H, Okumiya M. Study on the design procedure for a multi-cool/heat tube system. Sol Energy 2009;83:1415–24.
  • [86] Mihalakakou G, Lewis J, Santamouris M. On the heating potential of buried pipes techniques-application in ireland. Energy Build 1996;24:19–25.
  • [87] Ahmed S, Amanullah M, Khan M, Rasul M, Hassan N. Parametric study on thermal performance of horizontal earth pipe cooling system in summer. Energy Convers Manag 2016;114:324–37.
  • [88] Sodha MS, Sawhney RL, Jayashankar BC, Sharma AK. Effect of different earth surface treatments on the thermal performance of a room coupled to an earth-air tunnel. Int J Energy Res 1990;14:337–54.
  • [89] Paepe MD, Janssen M. Thermo-hydraulic design of earthair heat exchangers. Energy Build 2003;35:389–97.
  • [90] Sodha MS, Buddhi D, Sawhney RL. Thermal performance of underground air pipe: different earth surface treatments. Energy Convers Manag 1991;31(1):95–104.
  • [91] Sawhney R, Mahatan U. Heating and cooling potential of an underground air-pipe system. Int J Energy Res 1994;18:509–24.
  • [92] Bansal V, Misra R, Agrawal GD, Mathur J. Performance analysis of earth pipe air heat exchanger for summer cooling. Energy Build 2010;42(5):645–8.
  • [93] Niu F, Yu Y, Yu D, Li H. Investigation on soil thermal saturation and recovery of an earth to air heat exchanger under different operation strategies. Appl Therm Eng 2015;77:90–100.
  • [94] Yang D, Guo Y, Zhang J. Evaluation of the thermal performance of an earth-to-air heat exchanger (eahe) in a harmonic thermal environment. Energy Convers Manag 2016;109:184–194
  • [95] Goswami D, Iieslamlou S. Performance analysis of closed loop climate control system using underground air tunnel. J Sol Energy Eng 1990;112:76–81.
  • [96] Ahmed S, Khan M, Amanullah M, Rasul M, Hassan N. Performance assessment of earth pipe cooling system for low energy buildings in a subtropical climate. Energy Convers Manag 2015;106:815–25.
  • [97] Mathur A, Priyam , Mathur S, Agrawal G, Mathur J. Comparative study of straight and spiral earth air tunnel heat exchanger system operated in cooling and heating modes. Renew Energy 2017;108:474–87.
  • [98] Breesch H, Bossaer A, Janssens A. Passive cooling in a low-energy office building.Sol Energy 2005;79:682–96.
  • [99] Darkwa J, Kokogiannakis G, Magadzire C, Yuan K. Theoretical and practical evaluation of an earth-tube (e-tube) ventilation system. Energy Build 2011;43:728–36.
  • [100] Maerefat M, Haghighi A. Passive cooling of buildings by using integrated earth to air heat exchanger and solar chimney. Renew Energy 2010;35:2316–24.
  • [101] Li H, Yu Y, Niu F, Shafik M, Chen B. Performance of a coupled cooling system with earth-to-air heat exchanger and solar chimney. Renew Energy 2014;62:468–77.
  • [102] Benhammou M, Draoui B, Zerrouki M, Marif Y. Performance analysis of an earth to-air heat exchanger assisted by a wind tower for passive cooling of buildings in arid and hot climate. Energy Convers Manag 2015;91:1–11.
  • [103] Thiers S, Peuportier B. Thermal and environmental assessment of a passive building equipped with an earth-to-air heat exchanger in france. Sol Energy 2008;82:820–31.[133] Boji'c M. Optimization of heating and cooling of building by employing refuse and renewable energy. Renew Energy 2000;20:453–65.
  • [104] Barakat S, Ramzy A, Hamed A, Emam SE. Enhancement of gas turbine power output using earth to air heat exchanger (eahe) cooling system. Energy Convers Manag 2016;111:137–46.
  • [105] Bansal V, Misra R, Agrawal GD, Mathur J. Performance analysis of earthpipeair heat exchanger for summer cooling. Energy Build 2010;42:645–8.
  • [106] Bojic M, Trifunovic N, Papadakis G, Kytitsis S. Numerical simulation, technical and economic evaluation of air-toearth heat exchanger coupled to a building. Energy 1997;22:1151–8.
  • [107] Su H, Liu X-B, Ji L, Mu J-Y. A numerical model of a deeply buried air-earth-tunnel heat exchanger. Energy Build 2012;48:233–9.
  • [108] Gan G. Simulation of dynamic interactions of the earth air heat exchanger with soil and atmosphere for preheating of ventilation air. Appl Energy 2015;158:118–32.
  • [109] Gan G. Dynamic interactions between the ground heat exchanger and environments in earth air tunnel ventilation of buildings. Energy Build 2014;85:12-22.
  • [110] Singh S. Optimization of earth air tunnel system for space cooling. Energy Convers Manag 1994;35(8):721–5.
  • [111] Rohit Misra , Sanjeev Jakhar , Kamal Kumar Agrawal , Shailendra Sharma , Doraj Kamal Jamuwa , Manoj S. Soni , Ghanshyam Das Agrawal. Field investigations to determine the thermal performance of earth air tunnel heat exchanger with dry and wet soil: Energy and exergetic analysis. Energy & Buildings 171 (2018) 107–115
  • [112] Kamal Kumar Agrawal , Rohit Misra , Tejpal Yadav , Ghanshyam Das Agrawal , Doraj Kamal Jamuwa. Experimental study to investigate the effect of water impregnation on thermal performance of earth air tunnel heat exchanger for summer cooling in hot and arid climate.
  • [113] Khabbaz M, Benhamou B, Limam K, Hollmuller P, Hamdi H, Bennouna A.Experimental and numerical study of an earth-to-air heat exchanger for air cooling in a residential building in hot semi-arid climate. Energy Build2016;125:109–21.
  • [114] Jakhar S, Misra R, Soni M, Gakkhar N. Parametric simulation and experimental analysis of earth air heat exchanger with solar air heating duct. Eng Sci Technol, Int J 2016;19(2):1059–66.
  • [115] Niu F, Yu Y, Yu D, Li H. Heat and mass transfer performance analysis and cooling capacity prediction of earth to air heat exchanger. Appl Energy2015;137:211–21.
  • [116] Aliyah NI, Sanusi a NZ. Passive ground cooling system for low energy buildings in malaysia (hot and humid climates). Renew Energy 2013;49:193–6.
  • [117] Misra R, Bansal V, Agrawal GD, Mathur J, Aseri T. CFD analysis based parametric study of derating factor for earth air tunnel heat exchanger Applied.Energy 2013;103(266–277).
  • [118] Amin Haghighi Poshtiri, Neda Gilani, Farshad zamiri.Feasibility study on using solar chimney and earth-to-air heat exchanger for natural heating of buildings.World renewable energy congress 2011- Sweden.
  • [119] Anuj Mathur, Ayushman Srivastavab, G.D. Agrawala, Sanjay Mathura,Jyotirmay Mathura. CFD analysis of EATHE system under transient conditions forintermittent operation. Energy and Buildings 87 (2015) 37–44. www.elsevier.com/locate/enbuild.
  • [120] Anuj Mathur , Priyam a, Sanjay Mathur , *, G.D. Agrawal , Jyotirmay Mathur. Comparative study of straight and spiral earth air tunnel heat exchanger system operated in cooling and heating modes.
  • [121] Verma M.K., Bansal V., Rana K.B. (2019) Study on Performance Analysis of Earth-Air-Pipe Heat Exchanger as Passive Cooling and Heating System. Advances in Fluid and Thermal Engineering. Lecture Notes in Mechanical Engineering. Springer, Singapore. https://doi.org/10.1007/978-981-13-6416-7_77