GÜNEŞ DAMITICININ PERFORMANSINA ÜFLEYİCİ HAVA DEBİSİNİN ETKİSİ

GÜNEŞ DAMITICININ PERFORMANSINA ÜFLEYİCİ HAVA DEBİSİNİN ETKİSİ

Solar distillation is one of the important methods for water purification. This paper examines the performance of solar distillation system at different air flow rate. To increase the performance of distiller, artificial wind was created by fan and suitable wind speed was investigated to increase the amount of water distilled. The experiments were carried out in Elazığ climate conditions. In order to examine the effect of the wind speed on solar distillation system, two stills were manufactured with the size of 1000x1000 mm. One of them was the conventional still which was used as a reference. The other still was used to investigate experimentally the effect of the wind speed. Graphs were drawn for time-dependent changes in the amount of water distilled. It was found that that the productivity of the fan-still distiller was 14.7 % greater than that of a conventional still.

___

  • Ayav, P.I., and Atagündüz, G., 2007, Theoretical and experimental investigations on solar distillation of IZTECH campus area seawater, Desalination, 208, 169- 180.
  • Aybar, H.Ş., Egelioğlu, F., and Atikol, U., 2005, An experimental study on an inclined solar water distillation system, Desalination, 180, 285-289.
  • Aybar, H., 2006, Mathematical modeling of an inclined solar water distillation system, Desalination, 190, 63-70.
  • El-Sebaii, A.A., 2004, Effect of wind speed on active and passive solar stills, Energy Conversion and Management, 45, 1187–1204.
  • El-Sebaii, A.A.,2000, Effect of Wind Speed on Some Designs of Solar Stills. Energy Conversion and Management,41, 523-538.
  • Holman, J.P., 1994. Experimental Methods for Engineers, 6th edition. McGraw-Hill, Singapore.
  • Malik, M.A.S., Tiwari, G.N., Kumar, A., and Sodha, M.S., Solar Distillation, Pergamon Press, Oxford, UK, 1982.
  • Murugavel, K.K., Chockalingam, K.K.S.K., and Srithar,K., 2008, Progresses in improving the effectiveness of the single basin passive solar still, Desalination, 220, 677-686.
  • Nunez, J.C. T.,Gandara, M.A. P., Gortari, J.G. C., 2008, Exergy analysis of a passive solar still, Renewable Energy, 33, 608–616.
  • Sampathkumar, K., Arjunan, T.V., Pitchandi, P., and Senthilkumar, P., 2010, Active solar distillation—A detailed review, Renewable and Sustainable Energy Reviews, 14, 1503-1526.
  • Sharma, V.B. and Mullick, S.C., 1991, Estimation of heattransfer coefficients, the upward heat flow, and evaporationin a solar still, ASME Journal of Solar Engineering., 113, 36–41.
  • Shukla, S.K., Sorayan V.P.S., (2005), Thermal modeling of solar stills: an experimental validation, Renewable Energy, 30, 683–699.
  • Singh, A.K., and Tiwari, G.N., 1993, Thermal evaluation of regenerative active solar distillation under thermosyphon mode, Energy Conversion and Management, 34, 697–706.
  • Tanaka, H., 2010, Monthly optimum inclination of glass cover and external reflector of a basin type solar still with internal and external reflector, Solar Energy, 84, 1959- 1966.
  • Tiwari, G. N., Singh, H. N., and Tripathy, R., 2003, “Present Status of Solar Distillation ”Solar Energy, 75, , 367-373.
  • Tripathi, R., Tiwari, G.N., 2005, Effect of water depth on intemal heat and mass transfer for active solar distillation, Desalination, 173, 187-200.
  • Tellez, M.C., Figueroa, I.P.,Juarez, A.Z.,Zayas, J.F.,2014, Experimental study on the air velocity effect on the efficiency and fresh water production in a forced convective double slope solar still, Applied Thermal Engineering, 75, 1192-1200.
  • Vashishtha,R.,2014, Use of Renewable Energy Resources, International Journal of Sustainable Materials, Processes & ECO-Efficient – IJSMPE,1,10-12.
  • Wattmuf, J.H., Charters, W.W.S., Proctor, D., 1977, Solar and wind induced external coefficients for solar collectors, Cooperation Mediterraneenne pour l'Energie Solaire, Revue Internationale d'Heliotechnique, 2nd Quarter, p. 56.
  • Zurigat, Y.H, Abu-Arabi,M.K., 2004, Modelling and performance analysis of a regenerative solar desalination unit, Applied Thermal Engineering, 24, 1061–72.
Isı Bilimi ve Tekniği Dergisi-Cover
  • ISSN: 1300-3615
  • Yayın Aralığı: Yılda 2 Sayı
  • Başlangıç: 1977
  • Yayıncı: TÜRK ISI BİLİMİ VE TEKNİĞİ DERNEĞİ
Sayıdaki Diğer Makaleler

DEVELOPMENT OF A THERMAL MATHEMATICAL MODEL FOR THE SIMULATION OF TRANSIENT BEHAVIOR OF A SPACEBORNE EQUIPMENT IN VACUUM ENVIRONMENT

Ahmet Bilge UYGUR, Cem ÖMÜR

OPTIMUM SPACING BETWEEN HORIZONTAL METAL HYDRIDE (MH) HYDROGEN STORAGE TANKS INTEGRATED WITH FUEL CELL POWER SYSTEM IN NATURAL CONVECTION

İsmail HİLALİ

Dikdörtgensel Finlerde Doğrusal Olmayan Isı Transferi ve Sıcaklığa Bağlı Fiziksel Büyüklükler için Analitik Çözümler

M. TURKYILMAZOGLU

Kombiler İçin Yarı Küresel Gözenekli Metal Matris Yakıcının Geliştirilmesi

Muhammed Arslan OMAR, Kemal ALTINIŞIK, İbrahim Aslan REŞİTOĞLU

Ekserji Kaybı ve NTU Arasındaki İlişkinin İncelenmesi

O. KINCAY, M.S. CELLEK, O. ACIKGOZ, A.S. DALKILIC, S. WONGWISES

Güneş Damıtıcının Performansına Üfleyici Hava Debisinin Etkisi

Emin EL, Zeki ARGUNHAN, Gülşah ÇAKMAK, Halit Lütfü YÜCEL, Cengiz YILDIZ

Kısmi Olarak Dikey Duvarından Isıtılmış Kapalı Kare Geometride Birleşik Doğal Taşınım ve Işınımın Sayısal İncelenmesi

Mesut TEKKALMAZ

SECOND LAW ANALYSIS OF DIFFERENT REFRIGERANTS IN A TWO STAGE VAPOR COMPRESSION CYCLE

Ali KILIÇARSLAN, Sertaç Samed SEYİTOĞLU

Darbeli Boru Akışlarının Üretimi, Kontrolü ve İşlenmesine Dayalı Otomatik Bir Test Sistemi İçin Labview Programında Geliştirilen Bir Uygulama

Emrah ÖZAHİ, Melda Özdinç ÇARPINLIOĞLU

GÜNEŞ DAMITICININ PERFORMANSINA ÜFLEYİCİ HAVA DEBİSİNİN ETKİSİ

Cengiz YILDIZ, Emin EL, Zeki ARGUNHAN, Gülşah ÇAKMAK, Halit Lütfü YÜCEL