Amplatzer duct occluder II embedded by cook detachable coil like a sandwich to closure of residual patent ductus arteriosus
Transkateter patent duktus arteriyozus kapatılması standart bir klinik uygulamadır. Sunumumuzda 10 yaşında bir kız hastanın orta büyüklükteki patent duktus arteriyozusu önce Amplatzer duktal oklüder II kapatılmıştır sonrada rekanalizasyon nedeni ile cihaz Cook detachable koil içine gömülmüştür. Bu vaka sunumu çocuklarda bu kombinasyonun mümkün ve güvenli olduğunu göstermektedir.
Rezidüel duktus arteriyozus kapatılması sırasında Cook detachable koil içine sandeviç gibi gömülen Amplatzer duktal oklüder II
Transcatheter patent ductus arteriosus closure has developed standard clinical practice. We report a moderate patent ductus arteriosus in 10-year-old girl was closed with firstly Amplatzer duct occluder II and secondly the device was embedded by a Cook detachable coil because of ductal recanalization. This case report demonstrates that to apply this combination in children is feasible and safe.
___
- 1. Moore JW, Levi DS, Moore SD, Schneider DJ, Berdjis F. Interventional treatment of patent ductus arteriosus in 2004. Catheter Cardiovasc Interv 2005;64(1):91-101.
- 2. Turner DR, Forbes TJ, Epstein ML, Vincent JA. Early reopening and recanalization after successful coil occlusion of the patent ductus arteriosus. Am Heart J 2002;143(5);889-93.
- 3. Ovaert C, McCrindle BW, Nykanen D, Freedom RM, Benson LN. Transcatheter management of residual shunts after initial transcatheter closure of a patent arterial duct. Can J Cardiol 2003;19(13):1493-7.
- 4. Hofbeck M, Bartolomaeus G, Buheitel G, Esser R, Gravinghoff L, Hoffmann W, et al. Safety and efficacy of interventional occlusion of patent ductus arteriosus with detachable coils; a multicentre experience. Eur J Pediatr 2000;159(5):331-7.
- 5. Forsey J, Kenny D, Morgan G, Hayes A, Turner M, Tometzki A, et al. Early clinical experience with the new Amplatzer ductal occluder II for closure of the persistent arterial duct. Catheter Cardiovasc Interv 2009;74(4):615-23.
- 6. Daniels CJ, Cassidy SC, Teske DW, Wheller JJ, Allen HD. Reopening after successful coil occlusion for patent ductus arteriosus. J Am Coll Cardiol 1998;31(2):444-50.
- 7. Beck C, Laser KT, Haas NA. Failure of the Amplatzer Ductal Occluder II; Kinking of the aortic retention disk at 24 hours. Catheter Cardiovasc Interv 2010;75(7):1100-3.