Improved Performance of Doubly-Fed Induction Generator Wind Turbine During Transient State Considering Supercapacitor Control Strategy

Improved Performance of Doubly-Fed Induction Generator Wind Turbine During Transient State Considering Supercapacitor Control Strategy

This paper proposes a supercapacitor strategy for improving the capability of grid-connected doubly-fed induction generator (DFIG) wind turbines during fault scenarios. Supercapacitors are one of the important components in sustainable energy systems that are commonly used to store energy. In DFIGs, the supercapacitor is used to compensate for voltage dips and damping oscillations. In this work, a new topology of the supercapacitor system was used to investigate a DFIG wind turbine during transient state. The model system employed was a DFIG connected to the earlier wind turbine technology of fixed speed squirrel cage induction generator. Efforts were made to determine the effective parameters and switching strategies of the supercapacitor by considering different scenarios, in order to improve the transient state of the wind generator. The results obtained under severe grid fault were compared considering the different parameters of the resistance, inductance, and capacitance of the supercapacitor. The DC-link voltage and grid voltage switching strategies of the supercapacitor were investigated. Furthermore, the results of the proposed DFIG supercapacitor were compared with the traditional parallel capacitor scheme for DFIG system. For a fair comparison between the DFIG supercapacitor and parallel capacitor-based solution, the capacitance value considered was the same to buffer the transient energy.

___

  • 1. W. C. de Carvalho, R. P. Bataglioli, R. A. S. Fernandes, and D. V. Coury, “Fuzzy-based approach for power smoothing of a full-converter wind turbine generator using a supercapacitor energy storage,” Electr. Power Syst. Res., vol. 184, 2020. [CrossRef]
  • 2. A. Hooshyar, M. A. Azzouz, and E. F. El-Saadany, “Three-phase fault direction identification for distribution systems with DFIG-based wind DG,” IEEE Trans. Sustain. Energy, vol. 5, no. 3, pp. 747–756, 2014. [CrossRef]
  • 3. M. M. Kabsha, and Z. H. Rather, “Advanced LVRT control scheme for offshore wind power plant,” IEEE Trans. Power Deliv., vol. 36, no. 6, 3893–3902, 2021. [CrossRef]
  • 4. M. H. Zamani, G. Hossein Riahy, and M. Abedi, “Rotor-speed stability improvement of dual stator winding induction generator-based wind farms by control-windings voltage oriented control,” IEEE Trans. Power Electron., vol. 31, no. 8, pp. 5538–5546, 2016. [CrossRef].
  • 5. R. Prasad, and N. P. Padhy, “Synergistic frequency regulation control mechanism for DFIG wind turbines with optimal pitch dynamics,” IEEE Trans. Power Syst., vol. 35, no. 4, pp. 3181–3191, 2020. [CrossRef]
  • 6. A. M. A. Haidar, K. M. Muttaqi, and M. T. Hagh, “A coordinated control approach for DC link and Rotor Crowbars to improve fault ride-through of DFIG-based wind turbine,” IEEE Trans. Ind. Appl., vol. 53, no. 4, pp. 4073–4086, 2017. [CrossRef]
  • 7. K. E. Okedu, S. M. Muyeen, R. Takahashi, and J. Tamura, “Wind farms fault ride through using DFIG with new protection scheme,” IEEE Trans. Sustain. Energy, vol. 3, no. 2, pp. 242–254, 2012. [CrossRef]
  • 8. D. Xie, Z. Xu, L. Yang, J. Østergaard, Y. Xue, and K. P. Wong, “A comprehensive LVRT control strategy for DFIG wind turbines with enhanced reactive power support,” in IEEE Trans. Power Syst., vol. 28, no. 3, pp. 3302–3310. [CrossRef]
  • 9. J. Liang, W. Qiao, and R. G. Harley, “Feed-forward transient current control for low-voltage ride-through enhancement of DFIG wind turbines,” IEEE Trans. Energy Convers., vol. 25, no. 3, pp. 836–843. [CrossRef]
  • 10. R. Hiremath, and T. Moger, “Comprehensive review on low voltage ride through capability of wind turbine generators, ” Int. Trans. Electr. Energy Syst., vol. 30, no. 10, 2020. [CrossRef]
  • 11. Z. Zou, J. Liao, Y. Lei, Z. Mu, and X. Xiao, “Postfault LVRT performance enhancement of DFIG using a stage-controlled SSFCL-RSDR,” IEEE Trans. Appl. Supercond., vol. 29, no. 2, pp. 1–6. [CrossRef]
  • 12. J. Vidal, G. Abad, J. Arza, and S. Aurtenechea, “Single-phase DC crowbar topologies for low voltage ride through fulfillment of high-power doubly Fed Induction Generator-Based Wind Turbines,” IEEE Trans. Energy Convers., vol. 28, no. 3, pp. 768–781. [CrossRef]
  • 13. V. Yaramasu, B. Wu, S. Alepuz, and S. Kouro, “Predictive control for lowvoltage ride-through enhancement of three-level-boost and NPC-converter-based PMSG wind turbine,” IEEE Trans. Ind. Electron., vol. 61, no. 12, pp. 6832–6843, Dec. 2014. [CrossRef]
  • 14. O. P. Mahela, N. Gupta, M. Khosravy, and N. Patel, “Comprehensive overview of low voltage ride through methods of grid integrated wind generator,” IEEE Access, vol. 7, pp. 99299–99326, 2019. [CrossRef]
  • 15. S. Alepuz, A. Calle, S. Busquets-Monge, S. Kouro, and B. Wu, “Use of stored energy in PMSG rotor inertia for low-voltage ride-through in back-to-back NPC converter-based wind power systems,” IEEE Trans. Ind. Electron., vol. 60, no. 5, pp. 1787–1796, 2013. [CrossRef]
  • 16. A. Calle-Prado, S. Alepuz, J. Bordonau, P. Cortes, and J. Rodriguez, “Predictive control of a back-to-back NPC converter-based wind power system,” IEEE Trans. Ind. Electron., vol. 63, no. 7, pp. 4615–4627, 2016. [CrossRef]
  • 17. Z. Peng, and H. Yikang, “Control strategy of an active crowbar for DFIG based wind turbine under grid voltage dips,” International Conference on Electrical Machines and Systems (ICEMS), Seoul, 2007, pp. 259–264.
  • 18. L. Yang, Z. Xu, J. Ostergaard, Z. Y. Dong, and K. P. Wong, “Advanced control strategy of DFIG wind turbines for power system fault ride through,” IEEE Trans. Power Syst., vol. 27, no. 2, pp. 713–722. [CrossRef]
  • 19. S. Xiao, G. Yang, H. Zhou, and H. Geng, “An LVRT control strategy based on flux linkage tracking for DFIG-based WECS,” IEEE Trans. Ind. Electron., vol. 60, no. 7, pp. 2820–2832. [CrossRef]
  • 20. Q. Huang, X. Zou, D. Zhu, and Y. Kang, “Scaled current tracking control for doubly fed induction generator to ride-through serious grid faults,” IEEE Trans. Power Electron., vol. 31, no. 3, pp. 2150–2165, 2016. [CrossRef]
  • 21. R. Zhu, Z. Chen, X. Wu, and F. Deng, “Virtual damping flux-based LVRT control for DFIG-based wind turbine,” IEEE Trans. Energy Convers., vol. 30, no. 2, pp. 714–725, 2015. [CrossRef]
  • 22. D. Zhu, X. Zou, S. Zhou, W. Dong, Y. Kang, and J. Hu, “Feedforward current references control for DFIG-based wind turbine to improve transient control performance during grid faults,” IEEE Trans. Energy Convers., vol. 33, no. 2, pp. 670–681, 2018. [CrossRef]
  • 23. J. Bhukya, and V. Mahajan, “Optimization of damping controller for PSS and SSSC to improve stability of interconnected system with DFIG based wind farm,” Int. J. Electr. Power Energy Syst., vol. 108, pp. 314–335, 2019. [CrossRef]
  • 24. M. J. Hossain, T. K. Saha, N. Mithulananthan, and H. R. Pota, “Control strategies for augmenting LVRT capability of DFIGs in interconnected power systems,” IEEE Trans. Ind. Electron., vol. 60, no. 6, pp. 2510–2522, 2013. [CrossRef]
  • 25. M. J. Hossain, H. R. Pota, V. A. Ugrinovskii, and R. A. Ramos, “Simultaneous STATCOM and pitch angle control for improved LVRT capability of fixedspeed wind turbines,” IEEE Trans. Sustain. Energy, vol. 1, no. 3, pp. 142–151, 2010. [CrossRef]
  • 26. I. M. Syed, B. Venkatesh, B. Wu, and A. B. Nassif, “Two-layer control scheme for a supercapacitor energy storage system coupled to a doubly fed induction generator,” Electr. Power Syst. Res., vol. 86, pp. 76–83, 2012. [CrossRef]
  • 27. L. Qu, and W. Qiao, “Constant power control of DFIG wind turbines with supercapacitor energy storage,” IEEE Trans. Ind. Appl., vol. 47, no. 1, pp. 359–367, 2011. [CrossRef]
  • 28. V. Krishnamurthy, and C. R. Kumar, “A novel two layer constant power control of 15 DFIG wind turbines with supercapacitor energy storage,” Int. J. Adv. Innov., vol. 2, pp. 68–77, 2013.
  • 29. S. Dongyang, Z. Xiongxin, S. Lizhi, W. Fengjian, and Z. Guangxin, “Study on power fluctuation suppression of DFIG based on super capacitor energy storage,” In 2017 IEEE Conference on Energy Internet and Energy System Integration (EI2), Beijing, China: IEEE Publications, 2017, pp. 1–6.
  • 30. R. Suryana, “Frequency control of standalone wind turbine with supercapacitor,” In 33rd International Telecommun. Energy Conference (INTELEC), Amsterdam, Netherlands: IEEE Publications, 2011, pp. 1–8.
  • 31. R. Aghatehrani, R. Kavasseri, and R. C. Thapa, “Power smoothing of the DFIG wind turbine using a small energy storage device,” In IEEE PES Gen Meeting. Minnesota, USA: IEEE Publications, 2010, pp. 1–6.
  • 32. N. Mendis, K. M. Muttaqi, and S. Perera, Active Power Management of a Supercapacitor-Battery Hybrid Energy Storage System for Standalone Operation of DFIG Based Wind Turbines. IEEE Industry Applications Society Annual Meeting. Las Vegas, USA, 7–11 October, 2012.
  • 33. E. Naswali et al., Supercapacitor Energy Storage for Wind Energy Integration. IEEE Energy Conversion Congress and Exposition, Phoenix, Arizona, 17–22 September, 2011.
  • 34. S. Huang, Q. Wu, Y. Guo, and F. Rong, “Optimal active power control based on MPC for DFIG-based wind farm equipped with distributed energy storage systems,” Int. J. Electr. Power Energy Syst., vol. 113, pp. 154–163, 2019. [CrossRef]
  • 35. T. Wei, S. Wang, and Z. Qi, “Design of supercapacitor based ride through system for wind turbine pitch systems,” In International Conference on Electrical Machines and Systems (ICEMS), IEEE Publications, 2007, pp. 294–297.
  • 36. S. M. Muyeen, R. Takahashi, M. H. Ali, T. Murata, and J. Tamura, “Transient stability augmentation of power system including wind farms by using ECS,” IEEE Trans. Power Syst., vol. 23, no. 3, pp. 1179–1187, 2008. [CrossRef]
  • 37. N. Mendis, K. M. Muttaqi, S. Sayeef, and S. Perera, “Application of a hybrid energy storage in a remote area power supply system,” IEEE International Energy Conference, IEEE Publications, 2010, pp. 576–581.
  • 38. X. Li, C. Hu, C. Liu, and D. Xu, “Modeling and control of aggregated supercapacitor energy storage system for wind power generation,” In 34th Annual Conference of IEEE Industrial Electronics, IEEE Publications, 2008, pp. 3370–3375.
  • 39. H. Babazadeh, W. Gao, and X. Wang, “Controller design for a hybrid energy storage system enabling longer battery life in wind turbine generators,” In North American Power Symposium, Boston, MA, USA: IEEE Publications, 4-6 Aug. 2011. DOI: 10.1109/NAPS.2011.6025178.
  • 40. M. F. M. Arani, and E. F. El-Saadany, “Implementing virtual inertia in DFIGbased wind power generation,” IEEE Trans. Power Syst., vol. 28, no. 2, pp. 1373–1384, 2013. [CrossRef]
  • 41. D. Yang, H. C. Gao, L. Zhang, T. Zheng, L. Hua, and X. Zhang, “Short-term frequency support of a doubly-fed induction generator based on an adaptive power reference function,” Int. J. Electr. Power Energy Syst., vol. 119, 2020. [CrossRef]
  • 42. J. Zhu et al., “Synthetic inertia control strategy for doubly fed induction generator wind turbine generators using lithium-ion supercapacitors,” IEEE Trans. Energy Convers., vol. 33, no. 2, pp. 773–783, 2017. [CrossRef]
  • 43. L. Xiong, Y. Li, Y. Zhu, P. Yang, and Z. Xu, “Coordinated control schemes of super-capacitor and kinetic energy of DFIG for system frequency support,” Energies, vol. 11, no. 1, p. 103, 2018. [CrossRef]
  • 44. S. S. Sahoo, K. Chatterjee, and P. M. Tripathi, “A coordinated control strategy using supercapacitor energy storage and series dynamic resistor for enhancement of fault ride-through of doubly fed induction generator,” Int. J. Green Energy, vol. 16, no. 8, pp. 615–626, 2019. [CrossRef]
  • 45. O. Noureldeen, and M. M. Youssef, “Super-capacitor utilization for low voltage ride through improvement of grid-tied wind turbines,” In Nineteenth International Middle East. Power Syst. Conference (MEPCON), IEEE Publications, 2017, pp. 1305–1309.
  • 46. M. Garcia-Garcia, M. P. Comech, J. Sallan, and A. Liombart, “Modelling Wind Farms for Grid Disturbances Studies,” Science Direct Renew. Energy, vol. 33, pp. 2019–2026, 2008.
  • 47. K. E. Okedu, S. M. Muyeen, R. Takahashi, and J. Tamura, “Application of SDBR with DFIG to Augment Wind Farm Fault Ride Through,” 24th IEEEICEMS (International Conference on Electrical Machines and Systems), Beijing, China, 2011, pp. 1–6.
  • 48. K. E. Okedu, “Enhancing the performance of DFIG variable speed wind turbine using parallel integrated capacitor and modified modulated braking resistor,” IET Gener. Transm. Distrib., vol. 13, no. 15, pp. 3378–3387, 2019. [CrossRef]
  • 49. K. E. Okedu, “Improving the transient performance of DFIG wind turbine using pitch angle controller low pass filter timing and network side connected damper circuitry,” IET Renew. Power Gener., vol. 14, no. 7, pp. 1219–1227, 2020. [CrossRef]
  • 50. I. Zubia, J. X. Ostolaza, A. Susperrgui, and J. J. Ugartemendia, “Multimachine transient modeling of wind farms, an essential approach to the study of fault conditions in the distribution network,” Appl. Energy, vol. 89, no. 1, pp. 421–429, 2012. [CrossRef]
  • 51. X. Kong, Z. Z. Xianggen, and M. Wen, “Study of fault current characteristics of the DFIG considering dynamic response of the RSC,” IEEE Trans. Energy Convers., vol. 2, no. 2, pp. 278–287, 2014.
  • 52. A. B. Cultura, and Z. M. Salameh, “Modeling, evaluation and simulation of a supercapacitor module for energy storage application,” In International Conference on Computer Information Systems and Industrial Applications, Atlantis Press, 2015.
  • 53. M. K. Döşoğlu, and A. B. Arsoy, “Transient modeling and analysis of a DFIG based wind farm with supercapacitor energy storage,” Int. J. Electr. Power Energy Syst., vol. 78, pp. 414–421, 2016. [CrossRef]
  • 54. M. K. Döşoğlu, “Nonlinear dynamic modeling for fault ride-through capability of DFIG-based wind farm,” Nonlinear Dyn., vol. 89, no. 4, pp. 2683–2694, 2017. [CrossRef]
  • 55. R. Isermann, and M. Münchhof, Identification of Dynamic Systems: An Introduction with Applications. Berlin, Germany: Springer Science & Business Media, 2010.
  • 56. Y. Wang, C. Liu, R. Pan, and Z. Chen, “Modeling and state-of-charge prediction of lithium-ion battery and ultracapacitor hybrids with a co-estimator,” Energy, vol. 121, pp. 739–750, 2017. [CrossRef]
  • 57. M. Ceraolo, G. Lutzemberger, and D. Poli, “State-of-charge evaluation of supercapacitors,” J. Energy Storage, vol. 11, pp. 211–218, 2017. [CrossRef]
  • 58. M. Henry, B. Andrés, F. Cristina, Z. Pablo, L. Antonio, and A. General, “Parameter identification procedure used for the comparative study of supercapacitors models,” Energies, vol. 12, no. 1776, pp. 1–20, 2019.
  • 59. “PSCAD/EMTDC manual,” Manit. HVDC Lab, 2016.