The Range of Motion of Abduction and Opposition of the Thumb

Objectives: The range of motion (ROM) of the carpometacarpal joint of the thumb on abduction and opposition were studied in normal individuals. Study Design: The study included 40 volunteer medical students (20 males, 20 females; mean age 22.5 years). The range of motion of the carpometacarpal joint of the thumb was measured with the use of a digital inclinometer on abduction and opposition. The highest value obtained from three measurements was taken into account. Dominant and non-dominant thumbs were compared by the Mann-Whitney U-test. Results: The mean range of motion of the carpometacarpal joint of the thumb was found as 52.6 degrees on abduction, and 37.6 degrees on opposition. No significant differences were found between dominant and non-dominant thumbs in both sexes. Conclusion: The range of motion of the thumb in Turkish individuals was found consistent with average ranges reported in the literature. Turkish Başlık: El Başparmağının Abdüksiyon ve Oppozisyon Hareketlerinin ROM Değerleri Anahtar Kelimeler: El/anatomi ve histoloji; parmak eklemi/fizyoloji; hareket açıklığı, artiküler; başparmak/fizyoloji Amaç: Bu çalışmada, başparmak karpometakarpal eklemine ait abdüksiyon ve oppozisyon hareket açıklıkları denekler üzerinde araştırıldı. Çalışma Planı: Çalışmaya gönüllü 40 tıp öğrencisi (20 erkek, 20 kız; ort. yaş 22.5) alındı. Deneklerin iki elinde karpometakarpal ekleme ait abdüksiyon ve oppozisyon hareketleri elektronik dijital inklinometre ile ölçüldü. Üç kez yapılan ölçümlerde elde edilen en yüksek değer dikkate alındı. Deneklerin dominant ve karşı tarafları Mann-Whitney U-testiyle karşılaştırıldı. Bulgular: Başparmak karpometakarpal eklemine ait hareket açıklıkları abdüksiyonda ortalama 52.6 derece, oppozisyonda 37.6 derece bulundu. Her iki cinsiyette de dominant ve karşı taraf ellerin abdüksiyon ve oppozisyon hareketlerinde anlamlı farklılık görülmedi. Sonuç: Ölçülen başparmak hareket açıklıkları, klasik kaynaklarda bildirilen normal değerlere yakın bulundu.

The Range of Motion of Abduction and Opposition of the Thumb

Objectives: The range of motion (ROM) of the carpometacarpal joint of the thumb on abduction and opposition were studied in normal individuals. Study Design: The study included 40 volunteer medical students (20 males, 20 females; mean age 22.5 years). The range of motion of the carpometacarpal joint of the thumb was measured with the use of a digital inclinometer on abduction and opposition. The highest value obtained from three measurements was taken into account. Dominant and non-dominant thumbs were compared by the Mann-Whitney U-test. Results: The mean range of motion of the carpometacarpal joint of the thumb was found as 52.6 degrees on abduction, and 37.6 degrees on opposition. No significant differences were found between dominant and non-dominant thumbs in both sexes. Conclusion: The range of motion of the thumb in Turkish individuals was found consistent with average ranges reported in the literature. Turkish Başlık: El Başparmağının Abdüksiyon ve Oppozisyon Hareketlerinin ROM Değerleri Anahtar Kelimeler: El/anatomi ve histoloji; parmak eklemi/fizyoloji; hareket açıklığı, artiküler; başparmak/fizyoloji Amaç: Bu çalışmada, başparmak karpometakarpal eklemine ait abdüksiyon ve oppozisyon hareket açıklıkları denekler üzerinde araştırıldı. Çalışma Planı: Çalışmaya gönüllü 40 tıp öğrencisi (20 erkek, 20 kız; ort. yaş 22.5) alındı. Deneklerin iki elinde karpometakarpal ekleme ait abdüksiyon ve oppozisyon hareketleri elektronik dijital inklinometre ile ölçüldü. Üç kez yapılan ölçümlerde elde edilen en yüksek değer dikkate alındı. Deneklerin dominant ve karşı tarafları Mann-Whitney U-testiyle karşılaştırıldı. Bulgular: Başparmak karpometakarpal eklemine ait hareket açıklıkları abdüksiyonda ortalama 52.6 derece, oppozisyonda 37.6 derece bulundu. Her iki cinsiyette de dominant ve karşı taraf ellerin abdüksiyon ve oppozisyon hareketlerinde anlamlı farklılık görülmedi. Sonuç: Ölçülen başparmak hareket açıklıkları, klasik kaynaklarda bildirilen normal değerlere yakın bulundu.