Mechanochemical ablation of varicose veins with N-Butyl Cyanoacrylate: Six-month follow-up

Mechanochemical ablation of varicose veins with N-Butyl Cyanoacrylate: Six-month follow-up

Aim: The endovenous treatment with n-butyl cyanoacrylate (NBCA) is a new nontumescent ablation technique for symptomaticsaphenous vein reflux. The aim of the present study is to present six-month follow-up results of NBCA (VenaBlock) mechanochemicalablation technique.Material and Methods: Endovenous ablation was performed on 29 saphenous veinsof 23 patients between January 2017 and October2018 in our university hospital. All patients with six-month follow-up results were included. Patients’ pre- and postoperative datawere recorded.Results: This procedure was performed on eight small saphenous veins in seven patients and 21 great saphenous veins in 16patients. The mean saphenous vein diameters for great and small saphenous vein were 7.1 and 3.8, respectively. The mean lengthsfor great and small saphenous vein were 45 cm and 19 cm, respectively. Closure rates were 100% at one week, 100% at one month,100% at three months and 96% at six months. CEAP score was significantly improved (p

___

  • 1. Eroglu E, Yasim A, Ari M et al. Mid-term results in the treatment of varicose veins with N-butyl cyanoacrylate. Phlebology 2017;32: 665-9.
  • 2. Park I. Initial outcomes of cyanoacrylate closure, VenaSeal system, for the treatment of the incompetent great and small saphenous veins. Vasc Endovascular Surg 2017;51:545-9.
  • 3. Bissacco D, Stegher S, Calliari FM et al. Saphenous vein ablation with a new cyanoacrylate glue device: a systematic review on 1000 cases. Minim Invasive Ther Allied Technol 2019;28:6-14.
  • 4. Sarac A. Two-year follow-up of a n-butyl-2-cyanoacrylate glue ablation for the treatment of saphenous vein insufficiency with a novel application catheter with guiding light Vascular 2019;10:1708538118823838
  • 5. Almeida JI, Min RJ, Raabe R et al. Cyanoacrylate adhesive for the closure of truncal veins: 60-day swine model results. Vasc Endovascular Surg 2011;45:631-5.
  • 6. Almeida JI, Javier JJ, Mackay E, et al. First human use of cyanoacrylate adhesive for treatment of saphenous vein incompetence. J Vasc Surg Venous LymphatDisord 2013;1:174-80.
  • 7. Toonder IM, Lam YL, Lawson J, et al. Cyanoacrylate adhesive perforator embolization (CAPE) of incompetent perforating veins of the leg, a feasibility study. Phlebology 2014;29:49- 54.
  • 8. Morrison N, Gibson K, McEnroe S, et al. Randomized trial comparing cyanoacrylate embolization and radiofrequency ablation for incompetent great saphenous veins (VeClose). J VascSurg 2015;61:985-94.
  • 9. Bozkurt AK and Yılmaz MF. A prospective comparison of a new cyanoacrylate glue and laser ablation for the treatment of venous insufficiency. Phlebology 2016;31:106-13.
  • 10. Yavuz T, Acar AN, Aydın H et al. A retrospective study of a new n-butyl-2-cyanoacrylate glue ablation catheter incorporated with application guiding light for the treatment of venous insufficiency: Twelve-month results.Vascular 2018;26:547-55.
  • 11. Ovalı C, Sevin MB. Twelve-month efficacy and complications of cyanoacrylate embolization compared with radiofrequency ablation for incompetent great saphenous veins. J Vasc Surg Venous Lymphat Disord 2019;7:210-6. 1107
Annals of Medical Research-Cover
  • Yayın Aralığı: Aylık
  • Yayıncı: İnönü Üniversitesi Tıp Fakültesi