Mechanochemical ablation of varicose veins with N-Butyl Cyanoacrylate: Six-month follow-up
Mechanochemical ablation of varicose veins with N-Butyl Cyanoacrylate: Six-month follow-up
Aim: The endovenous treatment with n-butyl cyanoacrylate (NBCA) is a new nontumescent ablation technique for symptomaticsaphenous vein reflux. The aim of the present study is to present six-month follow-up results of NBCA (VenaBlock) mechanochemicalablation technique.Material and Methods: Endovenous ablation was performed on 29 saphenous veinsof 23 patients between January 2017 and October2018 in our university hospital. All patients with six-month follow-up results were included. Patients’ pre- and postoperative datawere recorded.Results: This procedure was performed on eight small saphenous veins in seven patients and 21 great saphenous veins in 16patients. The mean saphenous vein diameters for great and small saphenous vein were 7.1 and 3.8, respectively. The mean lengthsfor great and small saphenous vein were 45 cm and 19 cm, respectively. Closure rates were 100% at one week, 100% at one month,100% at three months and 96% at six months. CEAP score was significantly improved (p
___
- 1. Eroglu E, Yasim A, Ari M et al. Mid-term results in the
treatment of varicose veins with N-butyl cyanoacrylate.
Phlebology 2017;32: 665-9.
- 2. Park I. Initial outcomes of cyanoacrylate closure, VenaSeal
system, for the treatment of the incompetent great and small
saphenous veins. Vasc Endovascular Surg 2017;51:545-9.
- 3. Bissacco D, Stegher S, Calliari FM et al. Saphenous vein
ablation with a new cyanoacrylate glue device: a systematic
review on 1000 cases. Minim Invasive Ther Allied Technol
2019;28:6-14.
- 4. Sarac A. Two-year follow-up of a n-butyl-2-cyanoacrylate
glue ablation for the treatment of saphenous vein
insufficiency with a novel application catheter with guiding
light Vascular 2019;10:1708538118823838
- 5. Almeida JI, Min RJ, Raabe R et al. Cyanoacrylate adhesive
for the closure of truncal veins: 60-day swine model results.
Vasc Endovascular Surg 2011;45:631-5.
- 6. Almeida JI, Javier JJ, Mackay E, et al. First human use
of cyanoacrylate adhesive for treatment of saphenous
vein incompetence. J Vasc Surg Venous LymphatDisord
2013;1:174-80.
- 7. Toonder IM, Lam YL, Lawson J, et al. Cyanoacrylate adhesive
perforator embolization (CAPE) of incompetent perforating
veins of the leg, a feasibility study. Phlebology 2014;29:49-
54.
- 8. Morrison N, Gibson K, McEnroe S, et al. Randomized trial
comparing cyanoacrylate embolization and radiofrequency
ablation for incompetent great saphenous veins (VeClose).
J VascSurg 2015;61:985-94.
- 9. Bozkurt AK and Yılmaz MF. A prospective comparison of a
new cyanoacrylate glue and laser ablation for the treatment
of venous insufficiency. Phlebology 2016;31:106-13.
- 10. Yavuz T, Acar AN, Aydın H et al. A retrospective study of
a new n-butyl-2-cyanoacrylate glue ablation catheter
incorporated with application guiding light for the treatment
of venous insufficiency: Twelve-month results.Vascular
2018;26:547-55.
- 11. Ovalı C, Sevin MB. Twelve-month efficacy and complications
of cyanoacrylate embolization compared with
radiofrequency ablation for incompetent great saphenous
veins. J Vasc Surg Venous Lymphat Disord 2019;7:210-6.
1107