Osteolysis is observed around both bioabsorbable and nonabsorbable anchors on serial magnetic resonance images of patients undergoing arthroscopic rotator cuff repair

Objectives: The objective of this study was to evaluate the incidence of osteolysis around the bioabsorbable and nonabsorbable anchors using serial magnetic resonance imaging (MRI) and to determine the relationship between osteolysis and the retear rate after arthroscopic rotator cuff repair. Methods: From July 2012 to July 2014, 50 patients [28 men and 22 women; mean age, 56.4 (range: 45 e56) years] underwent arthroscopic rotator cuff repair for a medium-to large-size tear with double-row suture-bridge technique. The bioabsorbable anchors used in the medial row comprised hydroxyapatitepolylactic acid enantiomer, and the nonabsorbable anchors in the lateral row were polyetheretherketone (PEEK)-type anchors. All patients underwent MRI evaluation at 3, 6, and 12 months postoperatively to determine osteolysis and identify any retear. Results: The incidences of osteolysis at 3, 6, and 12 months postoperatively were 1%, 4%, and 6% with nonabsorbable anchors and 13%, 29%, and 39% with bioabsorbable anchors, respectively. The incidences of osteolysis were significantly higher with the bioabsorbable anchors than with the nonabsorbable anchors (P < 0.005 for all three follow-ups). There was no significant difference between osteolysis and non-osteolysis groups regarding the retear rate or retear size (P ¼ 0.189 and 0.069, respectively). Conclusions: Osteolysis was common around bioabsorbable anchors used for arthroscopic rotator cuff repair, and it also occurred around the PEEK-type nonabsorbable anchors. The incidence of osteolysis of nonabsorbable anchors was significantly lower than that of bioabsorbable anchors. Osteolysis did not significantly affect rotator cuff retear after arthroscopic repair with either bioabsorbable or nonabsorbable anchors

___

1. Craft DV, Moseley JB, Cawley PW, Noble PC. Fixation strength of rotator cuff repairs with suture anchors and the transosseous suture technique. J Shoulder Elbow Surg. 1996;5(1):32e40. https://doi.org/10.1016/S1058-2746(96)80028- 0. Epub 1996/01/01. PubMed PMID: 8919440.

2. Vandevenne JE, Vanhoenacker FM, Parizel PM, Butts Pauly K, Lang RK. Reduction of metal artefacts in musculoskeletal MR imaging. Jbr-btr. 2007;90(5):345e349. https://doi.org/10.1594/ecr2008/C-684. Epub 2007/12/ 19. PubMed PMID: 18085188.

3. Zlatkin MB. MRI of the postoperative shoulder. Skeletal Radiol. 2002;31(2): 63e80. https://doi.org/10.1007/s00256-001-0460-1. Epub 2002/02/06. PubMed PMID: 11828327.

4. Busfield BT, Anderson LJ. Sterile pretibial abscess after anterior cruciate reconstruction from bioabsorbable interference screws: a report of 2 cases. Arthroscopy. 2007;23(8):911.e1e911.e4. https://doi.org/10.1016/j.arthro.2006.07.025. Epub 2007/08/08. PubMed PMID: 17681221.

5. Speer KP, Warren RF, Pagnani M, Warner JJ. An arthroscopic technique for anterior stabilization of the shoulder with a bioabsorbable tack. J Bone Joint Surg Am. 1996;78(12):1801e1807. https://doi.org/10.2106/00004623- 199612000-00002. Epub 1996/12/01. PubMed PMID: 8986656.

6. Suchenski M, McCarthy MB, Chowaniec D, et al. Material properties and composition of soft-tissue fixation. Arthroscopy. 2010;26(6):821e831. https:// doi.org/10.1016/j.arthro.2009.12.026. Epub 2010/06/01. PubMed PMID: 20511042.

7. Weiler A, Helling HJ, Kirch U, Zirbes TK, Rehm KE. Foreign-body reaction and the course of osteolysis after polyglycolide implants for fracture fixation: experimental study in sheep. J Bone Joint Surg Br. 1996;78(3):369e376. https:// doi.org/10.1302/0301-620x.78b3.0780369. Epub 1996/05/01. PubMed PMID: 8636168.

8. Abu Bakar MS, Cheng MH, Tang SM, et al. Tensile properties, tension-tension fatigue and biological response of polyetheretherketone-hydroxyapatite composites for load-bearing orthopedic implants. Biomaterials. 2003;24(13): 2245e2250. https://doi.org/10.1016/s0142-9612(03)00028-0. Epub 2003/04/ 18. PubMed PMID: 12699660.

9. Toth JM, Wang M, Estes BT, Scifert JL, Seim 3rd HB, Turner AS. Polyetheretherketone as a biomaterial for spinal applications. Biomaterials. 2006;27(3):324e334. https://doi.org/10.1016/j.biomaterials.2005.07.011. Epub 2005/08/24. PubMed PMID: 16115677.

10. Shahrulazua A, Duckworth D, Bokor DJ. Perianchor radiolucency following PEEK suture anchor application associated with recurrent shoulder dislocation: a case report. Clin Ter. 2014;165(1):31e34. https://doi.org/10.7471/ ct.2014.1658. Epub 2014/03/05. PubMed PMID: 24589948.

11. Kim SH, Oh JH, Lee OS, Lee HR, Hargens AR. Postoperative imaging of bioabsorbable anchors in rotator cuff repair. Am J Sports Med. 2014;42(3): 552e557. https://doi.org/10.1177/0363546513517538. Epub 2014/01/17. PubMed PMID: 24431337.

12. Sugaya H, Maeda K, Matsuki K, Moriishi J. Repair integrity and functional outcome after arthroscopic double-row rotator cuff repair. A prospective outcome study. J Bone Joint Surg Am. 2007;89(5):953e960. https://doi.org/ 10.2106/JBJS.F.00512. Epub 2007/05/03. PubMed PMID: 17473131.

13. Pilge H, Spang J, Rose T, Wolter H, Woertler K, Imhoff AB. Osteolysis after rotator cuff repair with bioabsorbable anchors. Arch Orthop Trauma Surg. 2012;132(3):305e310. https://doi.org/10.1007/s00402-011-1369-3. Epub 2011/08/19. PubMed PMID: 21847551.

14. Burkart A, Imhoff AB, Roscher E. Foreign-body reaction to the bioabsorbable suretac device. Arthroscopy. 2000;16(1):91e95. https://doi.org/10.1016/s0749- 8063(00)90134-8. Epub 2000/01/08. PubMed PMID: 10627352.

15. Burkhart SS. Case report by Drs. Glueck, Wilson, and Johnson entitled "Extensive osteolysis after rotator cuff repair with a bioabsorbable suture anchor" (May 2005, pages 742-744). Am J Sports Med. 2005;33(11):1768. https:// doi.org/10.1177/0363546505280432. Epub 2005/10/19. PubMed PMID: 16230471.

16. Tuoheti Y, Itoi E, Yamamoto N, et al. Contact area, contact pressure, and pressure patterns of the tendon-bone interface after rotator cuff repair. Am J Sports Med. 2005;33(12):1869e1874. https://doi.org/10.1177/ 0363546505278256. Epub 2005/09/15. PubMed PMID: 16157853.

17. Kholinne E, Lee HJ, Kim SJ, Park SH, Jeon IH. The relationship between age, rotator cuff integrity, and osseous microarchitecture of greater tuberosity: where should we put anchor? Acta Orthop Traumatol Turc. 2018;52(1):22e26. https://doi.org/10.1016/j.aott.2017.10.002. Epub 2017/10/21. PubMed PMID: 29050856.

18. Agrawal CM, Athanasiou KA. Technique to control pH in vicinity of biodegrading PLA-PGA implants. J Biomed Mater Res. 1997;38(2):105e114. https:// doi.org/10.1002/(SICI)1097-4636(199722)38:2<105::AID-JBM4>3.0.CO;2-U. Epub 1997/07/01. PubMed PMID: 9178737.

19. Ruhe PQ, Hedberg EL, Padron NT, Spauwen PH, Jansen JA, Mikos AG. Biocompatibility and degradation of poly(DL-lactic-co-glycolic acid)/calcium phosphate cement composites. J Biomed Mater Res A. 2005;74(4):533e544. https:// doi.org/10.1002/jbm.a.30341. Epub 2005/07/26. PubMed PMID: 16041795.

20. Nho SJ, Provencher MT, Seroyer ST, Romeo AA. Bioabsorbable anchors in glenohumeral shoulder surgery. Arthroscopy. 2009;25(7):788e793. https:// doi.org/10.1016/j.arthro.2008.08.018. Epub 2009/06/30. PubMed PMID: 19560644.

21. Gunja NJ, Athanasiou KA. Biodegradable materials in arthroscopy. Sports Med Arthrosc. 2006;14(3):112e119. https://doi.org/10.1097/00132585-200609000- 00002. Epub 2006/12/01. PubMed PMID: 17135957.

22. Moisala AS, Jarvela T, Paakkala A, Paakkala T, Kannus P, Jarvinen M. Comparison of the bioabsorbable and metal screw fixation after ACL reconstruction with a hamstring autograft in MRI and clinical outcome: a prospective randomized study. Knee Surg Sports Traumatol Arthrosc. 2008;16(12):1080e1086. https:// doi.org/10.1007/s00167-008-0593-z. Epub 2008/09/03. PubMed PMID: 18762911.

23. Sano A, Itoi E, Konno N, Kido T, Urayama M, Sato K. Cystic changes of the humeral head on MR imaging. Relation to age and cuff-tears. Acta Orthop Scand. 1998;69(4):397e400. https://doi.org/10.3109/17453679808999054. Epub 1998/11/03. PubMed PMID: 9798449.

24. Simonian PT, Wickiewicz TL, O'Brien SJ, Dines JS, Schatz JA, Warren RF. Pretibial cyst formation after anterior cruciate ligament surgery with soft tissue autografts. Arthroscopy. 1998;14(2):215e220. https://doi.org/10.1053/ jars.2003.50045. Epub 1998/04/08. PubMed PMID: 9531136.

25. Malhan K, Kumar A, Rees D. Tibial cyst formation after anterior cruciate ligament reconstruction using a new bioabsorbable screw. Knee. 2002;9(1):73e75. https://doi.org/10.1016/s0968-0160(01)00109-0. Epub 2002/02/07. PubMed PMID: 11830385.

26. Wozniak TD, Kocabey Y, Klein S, Nyland J, Caborn DN. Influence of thread design on bioabsorbable interference screw insertion torque during retrograde fixation of a soft-tissue graft in synthetic bone. Arthroscopy. 2005;21(7): 815e819. https://doi.org/10.1016/j.arthro.2005.04.108. Epub 2005/07/14. PubMed PMID: 16012494.

27. Seil R, Rupp S, Krauss PW, Benz A, Kohn DM. Comparison of initial fixation strength between biodegradable and metallic interference screws and a pressfit fixation technique in a porcine model. Am J Sports Med. 1998;26(6): 815e819. https://doi.org/10.1177/03635465980260061301. Epub 1998/12/16. PubMed PMID: 9850784.
Acta Orthopaedica et Traumatologica Turcica-Cover
  • ISSN: 1017-995X
  • Başlangıç: 2015
  • Yayıncı: Türk Ortopedi ve Travmatoloji Derneği
Sayıdaki Diğer Makaleler

Comparison of surgical trends in zone 2 flexor tendon repair between Turkish and international surgeons

Seyyid Şerif ÜNSAL, Tuğrul YILDIRIM, Mehmet ARMANGİL

Osteolysis is observed around both bioabsorbable and nonabsorbable anchors on serial magnetic resonance images of patients undergoing arthroscopic rotator cuff repair

Ivan MİCİC, Erica KHOLİNNE, Jae-Man KWAK, Kyoung-Hwan KOH, In-Ho JEON

Reduction of periprosthetic Staphylococcus aureus infection by preoperative screening and decolonization of nasal carriers undergoing total knee arthroplasty

Xavier PELFORT, Alba ROMERO, Montserrat BRUGUES, Amparo GARCİA, Sergi GİL, Anna MARRON

Isokinetic Evaluation of Shoulder Strength and Endurance after Reverse Shoulder Arthroplasty: A Comparative Study

Ali ERŞEN, Fevzi BİRİŞİK, Serkan BAYRAM, Türker ŞAHİNKAYA, Mehmet DEMİREL, Ata Can ATALAR, Mehmet DEMİRHAN

Unusual localization and aggressive progression of large infantile fibrosarcoma

İsmail Burak ATALAY, Güray TOĞRAL

Double ulnar osteomy for the treatment of congenital radial head dislocation

Qiang JİE, Xiaoju LİANG, Xiaowei WANG, Yongtao WU, Ge WU, Bing WANG

Percutaneous fixation of Lisfranc joint injuries: A systematic review of the literature

Ioannis M. STAVRAKAKİS, George E. MAGARAKİS, Zacharias CHRİSTOFORAKİS

The effects of cryopreserved human amniotic membrane on fracture healing: Animal study

ENES SARI, MEHMET YALÇINOZAN, Barış POLAT, Hanife ÖZKAYALAR

Revision strategy for malunited tibial plateau fracture caused by failure of initial treatment

Jiang LİANGJUN, Zheng QİANG, Pan ZHİJUN, Hang Lİ

The thickness of heel fat-pad in patients with plantar fasciitis

Oktay BELHAN, Mehmet KAYA, MURAT GÜRGER