Problems in Urinary Iodine Determination Methods and an Automated Kinetic Assay As a Solution

Accurate, fast and economical urinary iodine measurement is very important in diagnosing iodine deficiency disorders. The urinary iodine determination method using ammonium persulfate digestion based on the Sandell-Kolthoff reaction was optimized and modified to kinetic and automated assay. Ammonium persulfate digestion was performed at +95 ºC in a water-bath to ± 0.1 ºC precision. The performance of both the Sandell-Kolthoff reaction at 37 ºC and its kinetic measurement at 340 nm was tested in a random access automated analyzer. For method comparison, urinary iodine concentrations were measured using both the conventional chloric acid digestion method and the kinetic automated method in 66 randomly selected apparently healthy peoples' urine samples and five working iodine calibrators. The method agreed well with the conventional chloric acid digestion method (n = 66; r = 0.937 ;y = 0.895x + 0.149; Sy/x = 0.136). The detection limit of assay was 0.10 µmol/L. The mean recovery of iodine was 97% (87-107%). The intra- and interassay CVs for samples with iodine concentrations between 0.20 and 3.14 µmol/L were £ 10%. Our study suggested that urinary iodine should be determined by kinetic reading at 340 nm wavelength in an automated analyzer instead of by manual endpoint measurement at 410 nm.The kinetic procedure presented here therefore offers an easier,faster,more accurate,and more economical method.

Problems in Urinary Iodine Determination Methods and an Automated Kinetic Assay As a Solution

Accurate, fast and economical urinary iodine measurement is very important in diagnosing iodine deficiency disorders. The urinary iodine determination method using ammonium persulfate digestion based on the Sandell-Kolthoff reaction was optimized and modified to kinetic and automated assay. Ammonium persulfate digestion was performed at +95 ºC in a water-bath to ± 0.1 ºC precision. The performance of both the Sandell-Kolthoff reaction at 37 ºC and its kinetic measurement at 340 nm was tested in a random access automated analyzer. For method comparison, urinary iodine concentrations were measured using both the conventional chloric acid digestion method and the kinetic automated method in 66 randomly selected apparently healthy peoples' urine samples and five working iodine calibrators. The method agreed well with the conventional chloric acid digestion method (n = 66; r = 0.937 ;y = 0.895x + 0.149; Sy/x = 0.136). The detection limit of assay was 0.10 µmol/L. The mean recovery of iodine was 97% (87-107%). The intra- and interassay CVs for samples with iodine concentrations between 0.20 and 3.14 µmol/L were £ 10%. Our study suggested that urinary iodine should be determined by kinetic reading at 340 nm wavelength in an automated analyzer instead of by manual endpoint measurement at 410 nm.The kinetic procedure presented here therefore offers an easier,faster,more accurate,and more economical method.
Turkish Journal of Medical Sciences-Cover
  • ISSN: 1300-0144
  • Yayın Aralığı: Yılda 6 Sayı
  • Yayıncı: TÜBİTAK
Sayıdaki Diğer Makaleler

PCR Analysis of HSV-Negative Erythema Multiforme for the Expression of Other Herpesviruses

Mukadder KOÇAK, Emel ERKEK, Özgül KISA, Çakır GÜNEY, Ahu BİROL

Problems in urinary lodine determination methods and an automated kinetic assay as a solution

Mustafa GÜLTEPE, Osman Metin İPÇİOĞLU, Kadir AVŞAR, Ömer ÖZCAN

Evaluation of Phagocytic Function of The Spleen After Splenic Artery Ligation in Secondary Hypersplenism

Celalettin VATANSEV, Sakir TEKİN, Mustafa SERDENGEÇTİ, Mustafa C. AVUNDUK, Mustafa ŞAHİN

Problems in Urinary Iodine Determination Methods and an Automated Kinetic Assay As a Solution

Mustafa GÜLTEPE

Lecithin: Cholesterol acyltransferase activity and cholesteryl ester transfer rate in patients with diabetes mellitus

Zehra SERDAR, Emre SARANDÖL, Sürmen Esma GÜR, Melahat DİRİCAN

Immunization of Mice with Plasmid DNA Encoding Hepatitis B Virus Core Antigen (HBcAg)

Yasemin BULUT, Hakan BULUT, Mehmet Ziya DOYMAZ

Subtalar Dislocations: a Report of Two Cases

Özcan PEHLİVAN, Can SOLAKOĞLU, İbrahim AKMAZ

Echinococcus Infestation of Quadriceps Femoris Muscle Misdiagnosed as a Soft Tissue Tumor (A Case Report)

Kaan ERLER, M. Taner ÖZDEMİR, Mustafa BAŞBOZKURT, U. Barış ÖZKAL, Mahmut KÖMÜRCÜ, Ömer GÜNHAN

Bilateral Intratesticular Varicocele in a Patient with a History of Bilateral Cryptorchidism

Nuri ERDOĞAN, Oğuz EKMEKCİOĞLU, Murat BAYKARA

Comparison of Indirect Methods for Lactose Malabsorption

İsmail KURT, Adnan HASİMİ, Türker KUTLUAY, Muhittin A. SERDAR, Mohammed Wael ABDU GHOUSH