Research on magnetic field state analysis of a nonsalient pole synchronous generator Baojun

Research on magnetic field state analysis of a nonsalient pole synchronous generator Baojun

This paper is based on the definition of minor asymmetric degree and the relative position of the magnetic field. The relative position of the magnetic field is the angle between the positive and negative sequence magnetic fields. The corresponding relationship between the nonsalient pole synchronous generator steady performance and the magnetic field state is discussed when the generator operates at minor asymmetry. To analyze this corresponding relationship, the Taylor expansion formula with Lagrange remainder and symmetrical components is adopted. We study the relationship between the armature current and the relative position of the magnetic field, deducing the armature current expressions with second-order remainders. The law of the armature voltage is also obtained by phasor analysis. As an example, this paper executes two-dimensional finite element numerical calculations on a nonsalient pole synchronous generator. The result shows that the numerical calculation agrees with the deduced expression, which verifies the correctness of the expressions. In the meantime, during the process of deducing the expressions, a method of calculating the positive and negative sequence currents is proposed and their effective range is offered. When the generator works at maximum overvoltage and maximum undervoltage, the specific value of the relative position of the magnetic field is presented. This paper has important implications for generator running and protection.

___

  • [1] Diedrich C, Dijkstra D, Hamaekers J, Randrianarivony M. A finite element study on the effect of curvature on the reinforcement of matrices by randomly distributed and curved nanotubes. J Comput Theor Nanos 2015; 12: 2108-2116.
  • [2] Kumar R, Abbas I, Sharma V. A finite element study of unsteady free convection h- eat and mass transfer in a Walters B viscoelastic flow past a semi-infinite vertical plate. J Comput Theor Nanos 2014; 11: 2469-2475.
  • [3] Abbas IA, Singh B. Finite element analysis in a rotating thermoelastic half-space with diffusion. J Comput Theor Nanos 2014; 11: 2276-2282.
  • [4] Ning YH, Liu C, Zhu SH. Design and finite element analysis of a hybrid excitation synchronous machine. Int J Appl Electrom 2015; 48: 11-19.
  • [5] Kar N, Murata T, Tamura J. A new method to evaluate the q-axis saturation characteristic of cylindrical-rotor synchronous generators. IEEE T Energy Conver 2000; 15: 269-276.
  • [6] Kar NC, El Serafi AM. Measure of the saturation characteristics in the quadrature axis of synchronous machines. IEEE T Energy Conver 2006; 21: 690-698.
  • [7] Ge BJ, Li YL, Li B. Study of starting process of pumped storage machines by static frequency converter. Elect Mach Control 2002; 6: 95-99.
  • [8] Wang D, Wu XZ, Ma WM. Air-gap MMF analysis of fifteen-phase induction motor with non-sinusoidal supply. Proceedings of the CSEE 2009; 29: 88-94.
  • [9] Xing JQ, Wang FX, Wang TY. Study on anti-demagnetization of magnet for high speed permanent magnet machine. IEEE T Appl Supercon 2010; 20: 856-860.
  • [10] Kang GH, Hur J, Nam H. Analysis of irreversible magnet demagnetization in line-start motors based on the finiteelement method. IEEE T Magnetics 2003; 39: 1488-1491.
  • [11] Liang YP, Huang H, Li LH. Numerical calculation of end region of large air-cooled turbogenerator. Proceedings of the CSEE 2007; 27: 73-77.
  • [12] Huang H, Feng JQ, Liang YP. Numerical calculation of stator end-leakage of large air-cooled turbo-generator. Large Electric Machine and Hydraulic Turbine 2006; 20-23 (in Chinese).
  • [13] Liu XF, Meng L, Luo YL. The saturation curve series of synchronous generators. Proceedings of the CSEE 2002; 22: 68-72.
  • [14] Li LY, Pan DH, Huang XZ. Analysis and optimization of ironless permanent-magnet linear motor for improving thrust. IEEE T Plasma Sci 2013; 41: 1188-1192.
  • [15] Pollard EI. Effects of negative-sequence currents on turbine-generator rotors. T Am Inst Electr Eng 1953; 72: 404-406.
  • [16] Zhang ZY, Ma HZ, Zhong Q, Zhao LJ. Negative sequence component characteristics analysis of PMSM under asymmetry operation condition. Electr Meas Inst 2014; 51: 46-50.
  • [17] Jiang T, Guo ZZ, Chen XY, Xue F. Fault analysis of polymorphic phase component in electric power system and the application in the asymmetry system. Proceedings of the CSEE 2005; 22: 70-74.
  • [18] Li WL, Sun JH, Sun HL. Calculation and analysis of eddy loss and temperature field in rotor of synchronous generator under steady state and negative sequence. T China Elec Soc 2012; 27: 174-182.
  • [19] Paithankar YG, Bhide SR. A fast method for sequence component filtering. Int J Elect Eng Educ 2003; 40: 66-71.
  • [20] Sengupta S, Mukhopadhyay AK. Development of microprocessor based negative phase sequence current monitoring unit and negative phase sequence relay for an AC generator. J Inst Eng 2001; 82: 220-226.
  • [21] Islam SM. Novel microprocessor based negative phase sequence relay and meter. Int J Elec Power 1996; 18: 547-552.
  • [22] Akagi H, Kanegauwa Y, Nabaes A. Instantaneous reactive power compensators comprising switch devices without energy storage components. IEEE T Ind Appl 1984; 20: 625-630.
  • [23] Takeda M, Ikeda K, Teramoto A. Harmonic current and reactive power compensation with an active filter. In: IEEE 1998 Power Electronics Specialists Conference; 11–14 April 1988; Kyoto, Japan. New York, NY, USA: IEEE. pp. 174-1179.
  • 24] Wang HW, Jiang WP, Wu YN. Study on last break trip fault of inverter station in 800 kV UHVDC project from Yunnan to Guangdong. Power Syst Technol 2008; 32: 6-9.
  • [25] Dong ML, Li XL, He JJ. Electromagnetic transient response characteristics of internal faults in UHVDC converter station and corresponding control strategy. Power Syst Technol 2010; 34: 5-10.
  • [26] Zhang BD, Luo B, Zhang JH. Generators merging network conditions accounting method based on the positive sequence fundamental voltage synthetic phasor. Proceedings of the CSEE 2006; 16: 52-56.