Performance optimisation of a sensing chamber using fluid dynamics simulation for electronic nose applications

Performance optimisation of a sensing chamber using fluid dynamics simulation for electronic nose applications

The sensor chamber plays a significant role in order to improve the performance of an electronic nose in terms of stability, repeatability, reproducibility, and sensitivity. Fluid dynamics simulations of six different configurations of 3D sensing chambers are presented to facilitate the efficient design of an electronic nose system comprising 64 sensor arrays. Numerical simulations were carried out to investigate the gas (zero air) flow behaviour inside these chambers under steady-state conditions for velocities ranging from 0.1 to 2 m/s using ANSYS software. Design optimisation was performed in terms of area coverage, velocity, and mass fraction. The results show that the area coverage and mass fraction distribution increase with flow velocity. The sensor chambers achieved more than 70% flow coverage over the sensors at a velocity beyond 0.7 m/s. In further chamber designs, four baffles were introduced at different positions in a two inlet and one outlet chamber model to enhance the performance of the chamber. The effect of baffle positions in the flow distribution was investigated through numerical simulations. Chamber designs with the introduction of baffles achieved a maximum mass fraction. Thus, the insertion of baffles improved the area coverage and mass fraction. In addition, to show the real-time applicability further simulations were performed in the optimised sensor chamber.

___

  • 1] Di Natale C, Macagnano A, Davide F, D’Amico A, Paolesse R et al. An electronic nose for food analysis. Sensors and Actuators B: Chemical 1997; 44 (1): 521-526.
  • [2] Dragonieri S, Annema JT, Schot R, van der Schee MP, Spanevello A et al. An electronic nose in the discrimination of patients with non-small cell lung cancer and COPD. Lung Cancer 2009; 64 (2): 166-170.
  • [3] Dragonieri S, Schot R, Mertens BJ, Le Cessie S, Gauw SA et al. An electronic nose in the discrimination of patients with asthma and controls. Journal of Allergy and Clinical Immunology 2007; 120 (4): 856-862.
  • [4] Capelli L, Sironi S, Del Rosso R. Electronic noses for environmental monitoring applications. Sensors 2014; 14 (11): 19979-20007.
  • [5] Afolabi AO, Afolabi TJ. Implementation of electronic nose technique in explosives detection. International Journal of Engineering and Science 2013; 2 (7): 10-17.
  • [6] Hatfield J, Neaves P, Hicks P, Persaud K, Travers P. Towards an integrated electronic nose using conducting polymer sensors. Sensors and Actuators B: Chemical 1994; 18 (1-3): 221-228.
  • [7] Berna A. Metal oxide sensors for electronic noses and their application to food analysis. Sensors 2010; 10 (4): 3882-3910.
  • [8] Wu TZ. A piezoelectric biosensor as an olfactory receptor for odour detection: electronic nose. Biosensors and Bioelectronics 1999; 14 (1): 9-18.
  • [9] Zhang X, Zhang M, Sun J, He C. Design of a bionic electronic nose for robot. In: Proceedings of the ISECS International Colloquium on Computing, Communication, Control, and Management; Guangzhou, China; 2008. pp. 18-23.
  • [10] Gardner JW, Bartlett PN. Electronic noses: principles and applications. Measurement Science and Technology 2000; 11: 1087.
  • [11] Falcitelli M, Benassi A, Di Francesco F, Domenici C, Marano L et al. Fluid dynamic simulation of a measurement chamber for electronic noses. Sensors and Actuators B: Chemical 2002; 85 (1): 166-174.
  • [12] Viccione G, Spiniello D, Zarra T, Naddeo V. Fluid dynamic simulation of odour measurement chamber. Chemical Engineering Transactions 2014; 40: 109-114.
  • [13] Scott S, James D, Ali Z, O’Hare W. Optimising of the sensing chamber of an array of a volatile detection system. Journal of Thermal Analysis and Calorimetry 2004; 76 (2): 693-708.
  • [14] Viccione G, Zarrab T, Giulianib S, Naddeob V, Belgiornob V. Performance study of e-nose measurement chamber for environmental odour monitoring. Chemical Engineering 2012; 30: 109-114.
  • [15] Lezzi A, Beretta G, Comini E, Faglia G, Galli G et al. Influence of gaseous species transport on the response of solid state gas sensors within enclosures. Sensors and Actuators B: Chemical 2001; 78 (1): 144-150.
Turkish Journal of Electrical Engineering and Computer Sciences-Cover
  • ISSN: 1300-0632
  • Yayın Aralığı: Yılda 6 Sayı
  • Yayıncı: TÜBİTAK