The existence of ultrahigh voltage direct-current (UHVDC) transmission lines impacts geoelectric field observation (GFO), which further disturbs earthquake observation and prediction. We proposed a mathematic method based on a 3-dimensional layered soil model to calculate the interference and conducted GFO experiments at observatories and field observation sites during the live debugging of a ±800 kV UHVDC transmission line to verify the method. The results obtained by using the proposed method are in good accordance with the experimental results and the maximum error is no more than 15%. Moreover, the experiment proves that grounding current is a decisive factor in the interference from a transmission line to GFO.

___

  • [1] Liu ZY. Ultra-High Voltage Grid. Beijing, China: China Economy Press, 2006 (in Chinese).
  • [2] Zhao WJ. HVDC Engineering Technology. Beijing, China: China Electric Power Press, 2004 (in Chinese).
  • [3] Hu YX. Earthquake Engineering. Beijing, China: Earthquake Press, 2006 (in Chinese).
  • [4] Electric Power Research Institute of Energy Department. Experimental Research of Environmental Impact from 500. kV Power Line (Experimental Research on Seismic Station from Power Lines). Beijing, China: China Electric Power Research Institute, 1989 (in Chinese).
  • [5] Tang B, Zheng X, Zhang JG, Liu XF, Ge GZ. Interference from UHVDC power line on geomagnetic observation and its correction. IEEE T Power Deliver 2013; 28: 1111-1119.
  • [6] Qi L, Cui X, Wu Y. Minimum distance between AC transmission line and seismic observation station. High Voltage Engineering 2010; 36: 649-656.
  • [7] Tang B, Wen YF, Liu HZ, Zhang XW, De DQ, Fang FQ. Influence of DC transmission line on geomagnetic observation. High Voltage Engineering 2011; 37: 952-960.
  • [8] Shi HJ. Analysis on the interference factors in geoelectric field observation. Seismological Research of Northeast China 2009; 25: 51-57.
  • [9] Fang W, Zhang GQ, Shao HC. Study on the impact of HVDC to geoelectric field observation. Seismology and Geology 2010; 32: 434-441.
  • [10] Tang B, Zhang XW, Ge GZ, Zhang JG, Liu XF, Qu ZH. Interference on geoelectric field observation from UHVDC power line and its ground electrode. High Voltage Engineering 2013; 39: 2951-2959.
  • [11] Tang B, Ge GZ, Zhang JG, Liu XF, Huang Y. Interference from UHVDC power lines on geoelectric field observation with different electrode arrangements. East China Electric Power 2013; 41: 1653-1657.
  • [12] Monitoring and Prediction Department, China Earthquake Administration. Digital Observation Technology of Seismic Electromagnetic. Beijing, China: Earthquake Press, 2002 (in Chinese).
  • [13] Standardization Administration of China. Technical Requirement for the Observational Environment of Seismic Stations - Part 2: Electromagnetic Observation. Beijing, China: Standard Press of China, 2004 (in Chinese).
  • [14] Yuan JS, Li ZX. Complex image method for calculating electrostatic field in multilayer media. Journal of Tsinghua University (Science & Technology) 1999; 39: 51-53.
  • [15] Villas JET, Portela CM. Calculation of electric field and potential distributions
  • [16] Pang ZH, Zhang L, Tan B, Wen XS. Green’s function of vertical multi-layer soil. Proceedings of the CSEE 2011; 31: 150-156.
  • [17] Sun JZ, Liu L. Derivation of Green’s function by equivalent complex image method in a horizontal and vertical combined-layer soil structure. Proceedings of the CSEE 2003; 23: 146-151.
Turkish Journal of Electrical Engineering and Computer Sciences-Cover
  • ISSN: 1300-0632
  • Yayın Aralığı: Yılda 6 Sayı
  • Yayıncı: TÜBİTAK