Behavior of metamaterial-based microwave components for sensing and heating of nanoliter-scale volumes
Behavior of metamaterial-based microwave components for sensing and heating of nanoliter-scale volumes
Metamaterial-based microwave components are among the state-of-the-art heater and sensor designs for microfluidic systems. The miniaturization and energy-focusing abilities of the metamaterial-based components make it possible to adopt microwave components operating at wavelengths in the order of 10 cm for microfluidic systems. Microwave systems are particularly advantageous for point-of-care and high-throughput applications due to their high speed of operation, very low instrumentation cost, ability to selectively and internally heat specimens, and ability of label-free sensing. In this study, the efficiency and behavior of microwave components designed for heating and sensing small volumes in the scale of nanoliters are studied. In the heating behavior, an optimum passivation layer thickness that depends on the permittivity of the chip material is observed. Increasing the permittivity of the chip material increases the optimum passivation layer thickness. For a typical microfluidic environment that uses polydimethylsiloxane as the chip material and a lossy substrate, 37.4% of incoming microwave power is converted to heat within a 3-nL droplet. Increasing the permittivity of the chip material increases the heating efficiency. The sensing performance of the component shows that a 3-nL droplet generates a shift of 330 MHz (11.3%) in the resonance frequency. There is an optimum chip material permittivity that maximizes the shift in the resonance frequency. Increasing the passivation layer thickness reduces the sensitivity. Results provide a guideline for microwave heater and sensor designs in microfluidic platforms.
___
- [1] Janasek D, Franzke J, Manz A. Scaling and the design of miniaturized chemical-analysis systems. Nature 2006; 442: 374-380.
- [2] deMello AJ. Control and detection of chemical reactions in microfluidic systems. Nature 2006; 442: 394-402.
- [3] Beebe DJ, Mensing GA, Walker GM. Physics and applications of microfluidics in biology. Annu Rev Biomed Eng 2002; 4: 261-286.
- [4] Kim U, Ghanbari S, Ravikumar A, Seubert J, Figueira S. Rapid, affordable, and point-of-care water monitoring via a microfluidic dna sensor and a mobile interface for global health. IEEE J Transl Eng Health Med 2013; 1: 3700207.
- [5] Culbertson CT, Mickleburgh TG, Stewart-James SA, Sellens KA, Pressnall M. Micro total analysis systems: fundamental advances and biological applications. Anal Chem 2014; 86: 95-118.
- [6] Shameli SM, Glawdel T, Fernand VE, Ren CL. Micellar affinity gradient focusing in a microfluidic chip with integrated bilinear temperature gradients. Electrophoresis 2012; 33: 2703-2710.
- [7] Abate AR, Hung T, Sperling RA, Mary P, Rotem A, Agresti JJ, Weiner MA, Weitz DA. DNA sequence analysis with droplet-based microfluidics. Lab Chip 2013; 13: 4864-4869.
- [8] Neuˇzil P, Giselbrecht S, L¨ange K, Huang TJ, Manz A. Revisiting lab-on-a-chip technology for drug discovery. Nat Rev Drug Discov 2012; 11: 620-632.
- [9] Huh D, Hamilton GA, Ingber DE. From 3{D}cell culture to organs-on-chips. Trends Cell Biol 2011; 21: 745-754.
- [10] Liu RH, Yang J, Lenigk R, Bonanno J, Grodzinski P. Self-contained, fully integrated biochip for sample preparation, polymerase chain reaction amplification, and DNA microarray detection. Anal Chem 2004; 76: 1824-1831.
- [11] de Mello AJ, Habgood M, Lancaster NL, Welton T, Wootton RCR. Precise temperature control in microfluidic devices using Joule heating of ionic liquids. Lab Chip 2004; 4: 417-419.
- [12] Maltezos G, Johnston M, Scherer A. Thermal management in microfluidics using micro-Peltier junctions. Appl Phys Lett 2005; 87: 154105.
- [13] Lee CY, Lee GB, Lin JL, Huang FC, Liao CS. Integrated microfluidic systems for cell lysis, mixing/pumping and DNA amplification. J Micromech Microeng 2005; 15: 1215-1223.
- [14] Vigolo D, Rusconi R, Piazza R, Stone HA. A portable device for temperature control along microchannels. Lab Chip 2010; 10: 795-798.
- [15] Kaigala GV, Hoang VN, Stickel A, Lauzon J, Manage D, Pilarski LM, Backhouse CJ. An inexpensive and portable microchip-based platform for integrated RT-PCR and capillary electrophoresis. Analyst 2008; 133: 331-338.
- [16] Kim H, Dixit S, Green CJ, Faris GW. Nanodroplet real-time PCR system with laser assisted heating. Opt Express 2009; 17: 218-227.
- [17] Baroud CN, de Saint Vincent MR, Delville JP. An optical toolbox for total control of droplet microfluidics. Lab Chip 2007; 7: 1029-1033.
- [18] Boybay MS, Jiao A, Glawdel T, Ren CL. Microwave sensing and heating of individual droplets in microfluidic devices. Lab Chip 2013: 13: 840-3846.
- [19] Tkaczyk AH, Tkaczyk ER, Norris TB, Takayama S. Microfluidic droplet consistency monitoring and encapsulated cell detection via laser excitation. J Mech Med Biol 2011; 11: 1-14.
- [20] Gawad S, Schild L, Renaud P. Micromachined impedance spectroscopy flow cytometer for cell analysis and particle sizing. Lab Chip 2001; 1: 76-82.
- [21] Wang F, Burns MA. Multiphase bioreaction microsystem with automated on-chip droplet operation. Lab Chip 2010; 10: 1308-1315.
- [22] Elbuken C, Glawdel T, Chan D, Ren CL. Detection of microdroplet size and speed using capacitive sensors. Sensor Actuat A-Phys 2011; 171: 55-62.
- [23] Vutha KM, Davaji B, Lee CH, Walker GM. A microfluidic device for thermal particle detection. Microfluid Nanofluid 2014; 17: 871-878.
- [24] Shah JJ, Sundaresan SG, Geist J, Reyes DR, Booth JC, Rao MV, Gaitan M. Microwave dielectric heating of fluids in an integrated microfluidic device. J Micromech Microeng 2007; 17: 2224-2230.
- [25] Issadore D, Humphry KJ, Brown KA, Sandberg L, Weitz DA, Westervelt RM. Microwave dielectric heating of drops in microfluidic devices. Lab Chip 2009; 9: 1701-1706.
- [26] Shaw KJ, Docker PT, Yelland JV, Dyer CE, Greenman J, Greenway GM, Haswell SJ. Rapid PCR amplification using a microfluidic device with integrated microwave heating and air impingement cooling. Lab Chip 2010; 10: 1725-1728.
- [27] Farcich NJ, Salonen J, Asbeck PM. Single-length method used to determine the dielectric constant of polydimethylsiloxane. IEEE T Microw Theory 2008; 56: 2963-2971.
- [28] Pozar DM. Microwave Engineering. 3rd ed. Hoboken, NJ, USA: Wiley, 2005.
- [29] Harrington RF. Time-Harmonic Electromagnetic Fields. New York, NY, USA: McGraw-Hill, 1961.