Detection of online PD signals in XLPE cables using the Bhattacharyya distance
Detection of online PD signals in XLPE cables using the Bhattacharyya distance
Partial discharge (PD) signal detection can be used for insulation monitoring of power system equipment. Online PD detection as a main task of insulation monitoring for different power system equipment is a difficult procedure when environmental noise is taken into account. This paper proposes a new scheme based on the Bhattacharyya distance approach with the main goal of detecting the PD signals in cross-linked polyethylene cables. The proposed method, as a preprocessing tool, can be used for detection of PD signals in a noisy environment. The simplicity and the accuracy of the Bhattacharyya distance approach are the 2 main advantages that grab the attention of the authors in introducing this technique for detection of PD signals in different high-voltage power devices. In order to remove noises between intervals of measurement of PD signals, other simple signal processing techniques should be used as postprocessing tools. Detection of PD signals in a noisy environment, i.e. finding the times of PD occurrences, is the most important and difficult stage in online PD signal monitoring. The Bhattacharyya distance method is a simple approach that can be used for detection of short duration time signals such as PDs.
___
- [1] Di Lorenzo del Gasale M, Schifani R. Partial discharge tests using CIGRE Method II. IEEE T Dielect El In 2000; 7: 133-140.
- [2] Boggs S, Densley J. Fundamentals of partial discharge in the context of field cable testing. IEEE Electr Insul M 2000; 16: 13-18.
- [3] Boggs SA. Partial discharge: overview and signal generation. IEEE Electr Insul M 1990; 6: 33-39.
- [4] Boggs SA. Partial discharge - part 3: cavity-induced PD in solid dielectrics. IEEE Electr Insul M 1990; 6: 11-16.
- [5] Chan JC, Duffy P, Hiivala LJ, Wasik J. Partial discharge - Part VIII: PD testing of solid dielectric cable. IEEE Electr Insul M 1991; 7: 9-16.
- [6] Stone GC. Partial discharge - Part VII: practical techniques for measuring PD in operating equipment. IEEE Electr Insul M 1991; 7: 9-19.
- [7] Knapp CH, Bansal R, Mashikian MS, Northrop RB. Signal processing techniques for partial discharge site location in shielded cables. IEEE T Power Deliver 1990; 5: 859-865.
- [8] Mashikian MS, Palmieri F, Bansal R, Northrop RB. Location of partial discharges in shielded cables in the presence of high noise. IEEE T Electr Insul M 1992; 27: 37-43.
- [9] Shim I, Soraghan JJ, Siew WH. Digital signal processing applied to the detection of partial discharge: an overview. IEEE Electr Insul M 2000; 16: 6-12.
- [10] Shim I, Soraghan JJ, Siew WH. Application of digital signal processing to the detection of partial discharge. Part 2: Optimized A/D conversion. IEEE Electr Insul M 2000; 16: 11-15.
- [11] Shim I, Soraghan JJ, Siew WH. Detection of PD utilizing digital signal processing methods part 3: open-loop noise reduction. IEEE Electr Insul M 2001; 17: 6-13.
- [12] Zhang H, Blackburn TR, Phung BT, Liu Z. Application of signal processing techniques to on-line partial discharge detection in cables. In: International Conference on Power System Technology; 2124 November 2004; Singapore. pp. 1029-1036.
- [13] Zargari A, Blackburn R. Application of adaptive filters for the estimation of partial discharge signals in noisy environments. In: 5th International Conference on Properties and Applications of Dielectric Materials; 2530 May 1997; Seoul, Korea. pp. 212-215.
- [14] Borsi H. Digital location of partial discharges in HV cables. IEEE T Electr Insul 1992; 27: 28-36.
- [15] Pommerenke D, Strehl T, Heinrich R, Kalkner W, Schmidt F, Weinenberg W. Discrimination between internal PD and other pulses using directional coupling sensors on HV cable systems. IEEE T Dielect El In 1999; 6: 814-824.
- [16] Tian Y, Lewin PL, Pommerenke D, Wilkinson JS, Sutton SJ. Partial discharge on-line monitoring for HV cable systems using electro-optic modulators. IEEE T Dielect El In 2004; 11: 861-869.
- [17] Ambikairajah R, Phung BT, Ravishankar J, Blackburn TR, Liu Z. Detection of partial discharge signals in high voltage XLPE cables using time domain features. In: Electrical Insulation Conference; 58 June 2011; Annapolis, MD, USA. pp. 364-367.
- [18] Zhang H, Blackburn TR, Phung BT, Sen D. A novel wavelet transform technique for on-line partial discharge measurements. Part 1: WT de-noising algorithm. IEEE T Dielect El In 2007; 14: 3-14.
- [19] Zhang H, Blackburn TR, Phung BT, Sen D. A novel wavelet transform technique for on-line partial discharge measurements. Part 2: On-site noise rejection application. IEEE T Dielect El In 2007; 14: 15-22.
- [20] Shim I, Soraghan JJ, Siew WH. A noise reduction technique for on-line detection and location of partial discharges in high voltage cable networks. Meas Sci Technol 2000; 11: 1708.
- [21] Niknazar M, Mousavi SR, Vosoughi Vahdat B, Shamsollahi MB, Sayyah M. A new dissimilarity index of EEG signals for epileptic seizure detection. In: 4th International Symposium on Communications, Control and Signal Processing; 35 March 2010; Limassol, Cyprus. pp. 1-5.
- [22] Mak B, Barnard E. Phone clustering using the Bhattacharyya distance. In: Fourth International Conference on ICSLP; October 1996; USA.
- [23] Donoho DL, Johnstone IM. Ideal spatial adaptation via wavelet shrinkage. Biometrika 1994; 81: 425-455.