Adaptive sliding mode with time delay control based on convolutions for power flow reference tracking using a VSC-HVDC system

Adaptive sliding mode with time delay control based on convolutions for power flow reference tracking using a VSC-HVDC system

This paper deals with the design of an adaptive sliding mode with a time delay control based on convolutions (ASMTDCC) approach for a voltage source converter (VSC) high voltage direct current (HVDC) transmission system for power flow reference tracking over a wide range of operating conditions considering parameter variations and external disturbances. For this purpose, the model of a VSC-HVDC transmission system connecting two asynchronous electrical grids is developed. The problem of designing an ASMTDCC feedback scheme, via a control strategy, is addressed seeking a better performance. For ensuring robust behavior and reducing chattering, the ASMTDCC scheme is realized based on time delay approximation and sliding mode techniques. Theoretical developments and results are illustrated through simulation results.

___

  • [1] Woodford DA. HVDC Transmission. Manitoba HVDC Research Centre, Manitoba, Canada, 1998.
  • [2] Aredes M, Aquino A, Santos G. Multipulse converters and controls for HVDC and FACTS systems. Electr Eng 2001; 83: 137-145.
  • [3] Moustafa M, Filizadeh S. HVDC model with reduced computational intensity. In: IEEE 2012 Power and Energy Society General Meeting; 22–26 July 2012; San Diego, CA, USA: IEEE. pp. 1-6.
  • [4] Rudervall R, Charpentier J, Sharma R. High Voltage Direct Current (HVDC) Transmission Systems Technology Review Paper. In: Energy Week 2000; March 7–8; Washington, DC, USA: 1-17.
  • [5] Ahmed M, Ebrahim M, Ramadan H, Becherif M. Optimal genetic-sliding mode control of VSC-HVDC transmission systems. In: Energy Procedia 2015 International Conference on Technologies and Materials for Renewable Energy, Environment and Sustainability, TMREES15 2015; April 17–20; Beirut, Lebanon 74: 1048-1060.
  • [6] Ayan K, Kılı¸c U. Optimal power flow of two-terminal HVDC systems using backtracking search algorithm. Int J Elec Power 2015; 78: 326-335.
  • [7] Carrizosa M, Navas F, Damm G, Lagarrigue F. Optimal power flow in multi-terminal HVDC grids with offshore wind farms and storage devices. Int J Elec Power 2015; 65: 291-298.
  • [8] Castro L, Acha E, Esquivel E. A novel VSC-HVDC link model for dynamic power system simulations. Electr Pow Syst Res 2015; 126: 111-120.
  • [9] Chen Y, Dai J, Damm G, Lagarrigue F. Small Signal Stability Analysis of Power System Equipped with VSC based Back to Back HVDC. In: IEEE 2015 2nd Int’l Conf. on Electrical Engineering and Information & Communication Technology (ICEEICT) 2015; 21–23 May 2015; Jahangirnagar University, Dhaka-1342, Bangladesh. USA: IEEE. pp. 1-6.
  • [10] Nnachi AF, Munda J, Nicolae DV, Mpanda AM. Transient stability analysis of VSC HVDC transmission with power injection on the DC-link. Turk J Elec Eng & Comp Sci 2015; 23: 1834-1852.
  • [11] Ruan S, Li G, Peng L, Sun Y, Lie T. A nonlinear control for enhancing HVDC light transmission system stability. Int J Elec Power 2007; 29: 565-570.
  • [12] Bidadfar A, Abedi M, Karrari M, Gharehpetian G, Tavana S. Passive AC network supplying the integration of CCC-HVDC and VSC-HVDC systems. Turk J Elec Eng & Comp Sci 2014; 22: 353-362.
  • [13] Guo C, Zhao C. A New Technology for HVDC Start-up and Operation Using VSC-HVDC System. In: IEEE 2009 Power and Energy Society General Meeting PES’09; 26-30 July 2009; Calgary, Alberta Canada, USA: IEEE. pp. 1-5.
  • [14] Mazouz L, Zidi S, Khatir M, Benmessaoud T, Saadi S. Particle swarm optimization based PI controller of VSCHVDC system connected to a wind farm. Int J Syst Assur Eng Manag 2015; 1-8.
  • [15] Liang H, Li G, Li G, Li P, Yin M. Analysis and Design of H∞ Controller in VSC-HVDC Systems. In: IEEE 2005 Transmission and Distribution Conference & Exhibition; 14–18 August 2005; Asia and Pacific Dalian, China, USA: IEEE. pp. 1-6.
  • [16] Ramadan H, Siguerdidjane H, Petit M, Kaczmarek R. Performance enhancement and robustness assessment of VSC-HVDC transmission systems controllers under uncertainties. Int J Elec Power 2012; 35: 34-46.
  • [17] Ramadan H, Siguerdidjane H, Petit M. A Robust Stabilizing Nonlinear Control Design for VSC-HVDC Systems: A Comparative Study. In: IEEE 2009 International Conference on Industrial Technology; 10–13 February 2009; Gippsland, Australia, USA: IEEE. pp. 1-6.
  • [18] Chen Y, Dai J, Damm G, Lagarrigue F. Nonlinear control design for a multi-terminal VSC-HVDC system. In: IEEE 2013 12th European Control Conference (ECC 2013); Jul 2013; Zurich, Switzerland, USA: IEEE. pp. 3536-3541.
  • [19] Ruan S, Li G, Jiao X, Sun Y, Lie T. Adaptive control design for VSC-HVDC systems based on backstepping method. Electr Pow Syst Res 2007; 77: 559-565.
  • [20] Rigatos G, Siano P, Wira P, Cecati C. A Global Linearization Approach to Control and State Estimation of a Voltage Source Converter: HVDC System. Intell Ind Syst 2015; 1: 331-344.
  • [21] Lee T. Lagrangian modeling and passivity-based control of three-phase AC/DC voltage-source converters. IEEE T Ind Electron 2004; 51: 892-902.
  • [22] Liu Y, Li R. A novel control method for a VSC-HVDC system in a grid-connected wind farm. Turk J Elec Eng & Comp Sci 2015; 23: 1558-1570.
  • [23] Youcef-Toumi K, Huang S. Analysis of a Time Delay Controller Based on Convolutions. In: IEEE 1993 Proceeding of the American Control Conference (ACC 1993); 2–4 June; San Francisco, California, USA: IEEE. pp. 2582 -2586.
  • [24] Wang Y, Yu D, Kim Y. Robust time-delay control for the DC-DC boost converter. IEEE T Ind Electron 2014; 61: 4829-4837.
  • [25] Lee S, Chang P. The development of anti-windup scheme for time delay control with switching action using integral sliding surface. J Dyn Syst-T ASME 2013; 125: 630-638.
  • [26] Köse E, Kizmaz H, Abaci K, Aksoy S. Control of SVC based on the sliding mode control method. Turk J Elec Eng & Comp Sci 2014; 22: 605-619.