A subsynchronous resonance prevention for DFIG-based wind farmsfarms
A subsynchronous resonance prevention for DFIG-based wind farmsfarms
n this paper, subsynchronous resonance (SSR) instability was accurately analyzed in doubly fed induction generator (DFIG)-based wind farms by the linearization of equations and modal analysis. In addition, the possibility of high compensation for the transmission lines connected to DFIG-based wind farms was provided using a SSR prevention controller (SSRPC). For this purpose, an SSRPC was connected to the output voltage of the grid side converter (GSC) of the DFIG. The GSC output voltage was selected as the connection point of the SSRPC because it directly affects the induction generator effect (IGE) and can be an inhibitor factor in its occurrence. Furthermore, using system dynamic equations and the participation factor, it was shown that the effective factor on subsynchronous mode was the capacitor series voltage of the line, considered an input signal to the SSRPC. To validate the performance of the proposed method, a simulation was performed based on the IEEE SSR first benchmark model using the software MATLAB/Simulink
___
- 1] Lie X, Cartwright P. Direct active and reactive power control of DFIG for wind energy generation. IEEE Transactions on Energy Conversion 2006; 21 (3): 750-758. doi: 10.1109/TEC.2006.875472
- [2] Mohammadpour HA, Santi E. Optimal adaptive sub-synchronous resonance damping controller for a series- compensated doubly-fed induction generator-based wind farm. IET Renewable Power Generation 2015; 9 (6): 669-681. doi: 10.1049/iet-rpg.2014.0155
- [3] Sahni M, Badrzadeh B, Muthumuni D, Cheng Y, Yin H et al. Sub-synchronous interaction in Wind Power Plants- part II: An ercot case study. In: IEEE Power and Energy Society General Meeting; San Diego, CA, USA; 2012. pp. 1-9.
- [4] Sahni M, Muthumuni D, Badrzadeh B, Gole A, Kulkarni A. Advanced screening techniques for Sub-Synchronous Interaction in wind farms. In: EEE PES Transmission and Distribution Conference and Exposition (T&D); Orlando, FL, USA; 2012. pp. 1-9.
- [5] Wang L, Xie X, Jiang Q, Pota HR. Mitigation of multimodal subsynchronous resonance via controlled injection of supersynchronous and subsynchronous currents. IEEE Transactions on Power Systems 2014; 29 (3): 1335-1344. doi: 10.1109/TPWRS.2013.2292597
- [6] Xie H, Oliveira MMD. Mitigation of SSR in presence of wind power and series compensation by SVC. In: Power System Technology (POWERCON); Chengdu, China; 2014. pp. 2819-2826.
- [7] Suriyaarachchi DHR, Annakkage UD, Karawita C, Kell D, Mendis R et al. Application of an SVC to damp sub- synchronous interaction between wind farms and series compensated transmission lines. In: IEEE Power and Energy Society General Meeting; San Diego, CA, USA; 2012. pp. 1-6.
- [8] Boopathi VP, Muzamil AR, Kumudini DRP, Ramanujam R. Analysis and mitigation of subsynchronous oscillations in a radially-connected wind farm. In: Power and Energy Systems: Ttowards Sustanable Eenergy ; Bangalore, India ; 2014. pp. 1-7.
- [9] Varma RK, Auddy S, Semsedini Y. Mitigation of subsynchronous resonance in a series-compensated wind farm using FACTS controllers. IEEE Transactions on Power Delivery 2008; 23 (3): 1645-1654. doi: 10.1109/TP- WRD.2008.917699
- [10] Mohammadpour HA, Santi E. Sub-synchronous resonance analysis in DFIG-based wind farms: mitigation methods- TCSC, GCSC, and DFIG controllers-part II. In: IEEE Energy Conversion Congress and Exposition (ECCE); Pittsburgh, PA, USA; 2014. pp. 1550-1557.
- [11] Mohammadpour HA, Santi E. Modeling and control of gate-controlled series capacitor interfaced with a DFIG-based wind farm. IEEE Transactions on Industrial Electronics 2015; 62 (2): 1022-1033. doi: 10.1109/TIE.2014.2347007
- [12] Mohammadpour HA, Shin YJ, Santi E. SSR analysis of a DFIG-based wind farm interfaced with a gate-controlled series capacitor. In: Twenty-Ninth Annual IEEE in Applied Power Electronics Conference and Exposition (APEC); Fort Worth, TX, USA; 2014. pp. 3110-3117.
- [13] Thirumalaivasan R. Janaki MR. Xu YJ. Kalman filter based detection and mitigation of subsynchronous resonance with SSSC. IEEE Transactions on Power Systems 2017; 32 (2): 1400-1409. doi: 10.1109/TPWRS.2016.2572301
- 14] Moursi MSE, Khadkikar V. Novel control strategies for SSR mitigation and damping power system oscillations in a series compensated wind park. In: 38th Annual Conference on IEEE Industrial Electronics Society in IECON; Montreal, QC, Canada; 2012, pp. 5335-5342.
- [15] Abdou AF, Abu-Siada A, Pota HR. Damping of subsynchronous oscillations and improve transient stability for wind farms. In: Innovative Smart Grid Technologies Asia (ISGT); Beijing, China; 2011. pp. 1-20.
- [16] Moharana A, Varma RK, R Seethapathy. SSR mitigation in wind farm connected to series compensated transmission line using STATCOM. In: IEEE Power Electronics and Machines in Wind Applications; Denver, CO, USA; 2012. pp. 1-8.
- [17] Moharana A, Varma RK, Seethapathy R. SSR alleviation by STATCOM in induction-generator-based wind farm connected to series compensated line. IEEE Transactions on Sustainable Energy 2014; 5 (3): 947-957. doi: 10.1109/TSTE.2014.2311072
- [18] Fan L, Miao Z. Mitigating SSR using DFIG-based wind generation. IEEE Transactions on Sustainable Energy 2012; 3 (3): 349-358. doi: 10.1109/TSTE.2012.2185962
- [19] Mohammadpour HA, Ghaderi A, Mohammadpour H, Santi E. SSR damping in wind farms using observed-state feed- back control of DFIG converters. Electric Power Systems Research 2015; 123: 57-66. doi: 10.1016/j.epsr.2015.01.018
- [20] Zhao B, Li H, Wang M, Chen Y, Liu S et al. An active power control strategy for a DFIG-based wind farm to depress the subsynchronous resonance of a power system. International Journal of Electrical Power & Energy Systems 2015; 69: 327-334. doi: 10.1016/j.ijepes.2015.01.002
- [21] Mohammadpour HA, Santi E. SSR damping controller design and optimal placement in rotor-side and grid-side converters of series-compensated DFIG-based wind farm. IEEE Transactions on Sustainable Energy 2015; 6 (2): 388-399. doi: 10.1109/TSTE.2014.2380782
- [22] Zhang X, Xie X, Liu H, Liu Hui, Li Y et al. Mitigation of sub-synchronous control interaction in wind power systems with GA-SA tuned damping controller. IFAC-PapersOnLine 2017; 50 (1): 8740-8745. doi: 10.1016/j.ifacol.2017.08.1730
- [23] Wang Y, Wu Q, Yang R, Tao G, Liu Z et al. H∞ current damping control of DFIG based wind farm for sub- synchronous control interaction mitigation. International Journal of Electrical Power & Energy Systems 2018; 98: 509-519. doi: 10.1016/j.ijepes.2017.12.003
- [24] Liu H, Xie X, Li Y, Liu H, Hu Y. Mitigation of SSR by embedding subsynchronous notch filters into DFIG converter controllers. IET Generation, Transmission & Distribution 2017; 11 (11): 2888-2896. doi: 10.1049/iet-gtd.2017.0138
- [25] Liu H, Xie X, Zhang C, Li Y, Liu H et al. Quantitative SSR analysis of series-compensated DFIG-based wind farms using aggregated RLC circuit model. IEEE Transactions on Power Systems 2017; 32 (1): 474-483. doi: 10.1109/TPWRS.2016.2558840
- [26] Xie X, Zhang X, Liu H, Liu Hui, Li Y et al. Characteristic analysis of subsynchronous resonance in practical wind farms connected to series-compensated transmissions. IEEE Transactions on Energy Conversion 2017; 32 (3): 1117-1126. doi: 10.1109/TEC.2017.2676024
- [27] Song Y, Blaabjerg F. Overview of DFIG-based wind power system resonances under weak networks. IEEE Trans- actions on Power Electronics 2017; 32 (6): 4370-4394. doi: 10.1109/TPEL.2016.2601643
- [28] Song Y, Wang X, Blaabjerg F. Impedance-based high-frequency resonance analysis of DFIG system in weak grids. IEEE Transactions on Power Electronics 2017; 32 (5): 3536-3548. doi: 10.1109/TPEL.2016.2584118
- [29] Chen W, Xie X, Wang D, Liu H, Liu Hui. Probabilistic stability analysis of subsynchronous resonance for series- compensated DFIG-based wind farms. IEEE Transactions on Sustainable Energy 2018; 9 (1): 400-409. doi: 10.1109/TSTE.2017.2737599
- [30] Xie H, Li B, Heyman C, Oliviera MMD, Monge M. Subsynchronous resonance characteristics in presence of doubly- fed induction generator and series compensation and mitigation of subsynchronous resonance by proper control of series capacitor. IET Renewable Power Generation 2014; 8 (4): 411-421. doi: 10.1049/iet-rpg.2013.0215