Determination of cadmium in high salt content matrices by flow injection cold vapor atomic absorption spectrometry

Flow injection cold vapor atomic absorption spectrometry (FI-CVAAS) was used for determination of cadmium in high salt matrices such as dialysis concentrates and textile leach solutions. The parameters such as acidity, concentration of reducing agent, reaction coil length, and carrier gas flow rate were investigated to obtain the best sensitivity. No significant background signal was observed even at high salt concentrations. Under the optimized conditions the limit of detection value (3sb m-1, where sb is the standard deviation of the blank signals and m is the slope of the calibration graph) was found to be 0.05 ng mL-1 for an injection volume of 250 m L and the precision in terms of relative standard deviation was 3.2% using 11 consecutive measurements of 0.5 ng mL-1 standard. The standard addition method was used for quantitation. The accuracy of the method was tested using ETAAS as a comparison method and a certified reference material (Waste Water EU-L-1). In both cases, the results were in good agreement at 95% confidence level. The concentrations of cadmium in textile product leach solutions were found to be below the limit value assigned by Oeko-Tex standards.

Determination of cadmium in high salt content matrices by flow injection cold vapor atomic absorption spectrometry

Flow injection cold vapor atomic absorption spectrometry (FI-CVAAS) was used for determination of cadmium in high salt matrices such as dialysis concentrates and textile leach solutions. The parameters such as acidity, concentration of reducing agent, reaction coil length, and carrier gas flow rate were investigated to obtain the best sensitivity. No significant background signal was observed even at high salt concentrations. Under the optimized conditions the limit of detection value (3sb m-1, where sb is the standard deviation of the blank signals and m is the slope of the calibration graph) was found to be 0.05 ng mL-1 for an injection volume of 250 m L and the precision in terms of relative standard deviation was 3.2% using 11 consecutive measurements of 0.5 ng mL-1 standard. The standard addition method was used for quantitation. The accuracy of the method was tested using ETAAS as a comparison method and a certified reference material (Waste Water EU-L-1). In both cases, the results were in good agreement at 95% confidence level. The concentrations of cadmium in textile product leach solutions were found to be below the limit value assigned by Oeko-Tex standards.
Turkish Journal of Chemistry-Cover
  • ISSN: 1300-0527
  • Yayın Aralığı: Yılda 6 Sayı
  • Yayıncı: TÜBİTAK
Sayıdaki Diğer Makaleler

Influence of reaction parameters on the synthesis of surfactant-assisted tin oxide nanoparticles

Muhammad Akhyar FARRUKH, Prisca Tan And Rohana ADNAN

99mTc labeled levofloxacin as an infection imaging agent: a novel method for labeling levofloxacin using cysteine\cdot HCl as co-ligand and in vivo study

Syed Ali Raza NAQVI, Malik Muhammad ISHFAQ, Zulfiqar Ali KHAN

Determination of cadmium in high salt content matrices by flow injection cold vapor atomic absorption spectrometry

Orkun ALP, Hakan DEMİRÖZ, Osman Yavuz ATAMAN, Nusret ERTAŞ

$^{99m}Tc$ labeled levofloxacin as an infection imaging agent: a novel method for labeling levofloxacin using cysteine·HCl as co-ligand and in vivo study

Nasir MAHMOOD, Zulfiqar Ali KHAN, Syed Ali Raza NAQVI, Malik Muhammad ISHFAQ, Saeed Ahmad NAGRA, Iftikhar Hussain BUKHARI, Abdullah Ijaz HUSSAIN, Sohail Anjum SHAHZAD, Asma HAQUE, Tanveer Hussain BOKHARI

Synthesis of some new urea and thiourea derivatives and evaluation of their antimicrobial activities

Yıldız GÜLKOK, Tuba BİÇER, Fatma Kaynak ONURDAĞ, Selda ÖZGEN

Synthesis, characterization, and microwave-promoted catalytic activity of novel benzimidazole salts bearing silicon-containing substituents in Heck-Mizoroki and Suzuki-Miyaura cross-coupling reactions under aerobic conditions

Hasan KÜÇÜKBAY, Nihat ŞİRECİ, Ülkü YILMAZ, Selma DENİZ, Mehmet AKKURT

Synthesis and evaluation of enzyme inhibitory potential of some derivatives of scopolamine

Durre SHAHWAR, Muhammad Asam RAZA, Tania KHAN

Theory of adsorption equilibria analysis based on general equilibrium constant expression

Abdul Sattar Ali KHAN

Simultaneous determination of Cr(III) and Cr(VI) using differential pulse polarography and application to Gerede River

Olcay ŞENDİL, Nabeel MOHAMMED, Güler SOMER

Preparation and antimicrobial activity evaluation of some quinoline derivatives containing an azole nucleus

Muhammet ÖZYANIK, Serpil DEMİRCİ, Hakan BEKTAŞ, Neslihan DEMİRBAŞ