Radius Kırıklarında Plak Fiksasyonu Ve İntramedüller Çivileme Yöntemlerinin Teorik Olarak İncelenmesi

While forearm fractures are often treated with plate-screw osteosynthesis, intramedullary nailing gained importance recently. For this aim, radius bone model was obtained using CT images, a fracture was introduced to the model and the callus, which is a structure forms during healing, was added to the model. Plate and intramedullary nail models were implemented to radius model. Structural behaviors of obtained models and callus on treatments with various implants were investigated under axial loading. In the light of these analyses, stresses on bone-implant structure and callus movement were investigated from the angle of application and treatment, depending on implant selection.

Theoretical Investigation Of Plate Fixation And Intramedullary Nailing Methods On Radius Fractures

-

___

  • Kovacı, H., Radius intramedüller çivilerde farklı sabitleme pozisyonları ile oluşan mekanik etkilerin sonlu elemanlar yöntemi ile incelenmesi. Atatürk Üniverisitesi, Fen Bilimleri Enstitüsü, 2011.
  • Weckbach, A., T. Blattert, and C. Weißer, Interlocking nailing of forearm fractures. Archives of Orthopaedic and Trauma Surgery, 2006. 126 (5): p. 309-315.
  • Jones, D.J., et al., A biomechanical comparison of two methods of fixation of fractures of the forearm. Journal of orthopaedic trauma, 1995. 9(3): p. 198.
  • Lee, Y.H., et al., Interlocking contoured intramedullary nail fixation for selected diaphyseal fractures of the forearm in adults. The Journal of Bone and Joint Surgery, 2008. 90 (9): p. 1891.
  • Houshian, S. and S.K. Bajaj, Forearm fractures in children:: Single bone fixation with elastic stable intramedullary nailing in 20 cases. Injury-International Journal of the Care of the Injured, 2005. 36 (12): p. 1421
  • Burkhart, K.J., et al., Intramedullary nailing vs. palmar locked plating for unstable dorsally comminuted distal radius fractures: A biomechanical study. Clinical Biomechanics, 2010. 25(8): p. 771-775.
  • Claes, L., et al., Influence of size and stability of the osteotomy gap on the success of fracture healing. Journal of orthopaedic research, 1997. 15 (4): p. 577-584.
  • Duda, G.N., et al., Interfragmentary movements in the early phase of healing in distraction and correction osteotomies stabilized with ring fixators. Langenbeck's Archives of Surgery, 2003. 387 (11): p. 433-440.
  • Kaspar, K., et al., Angle stable locking reduces interfragmentary movements and promotes healing after unreamed nailing. Study of a displaced osteotomy model in sheep tibiae. The Journal of Bone and Joint Surgery, 87 (9): p. 2028.
  • Klein, P., et al., The initial phase of fracture healing is specifically sensitive to mechanical conditions. Journal of orthopaedic research, 2003. 21 (4): p. 662-669.
  • Rogge, R.D., B.D. Adams, and V.K. Goel, An analysis of bone stresses and fixation stability using a finite element model of simulated distal radius fractures. The Journal of hand surgery, 2002. 27(1): p. 86-92.
  • Shefelbine, S.J., et al., Prediction of fracture callus mechanical properties using micro-CT images and voxel- based finite element analysis. Bone, 2005. 36 (3): p. 480-488.
  • Anderson, D.D., et al., A three-dimensional finite element model of the radiocarpal joint: distal radius fracture step-off and stress transfer. The Iowa Orthopaedic Journal, 2005. 25: p. 108.
  • Troy, K.L. and M.D. Grabiner, Off-axis loads cause failure of the distal radius at lower magnitudes than axial loads: a finite element analysis. Journal of biomechanics, 2007. 40 (8): p. 1670-1675.
Sakarya University Journal of Science-Cover
  • Yayın Aralığı: Yılda 6 Sayı
  • Başlangıç: 1997
  • Yayıncı: Sakarya Üniversitesi
Sayıdaki Diğer Makaleler

Tabanlık Yüksekliğinin Alt Ekstremite Üzerindeki Gerilme Dağılımına Ve Deformasyona Etkisi

Arif Özkan, Levent Buluç, Mehmet Yavuz Çırpıcı, Ümit Sefa Müezzinoğlu, Yasin Kişioğlu

Menisektomi Uygulanan Dizlerde Biyomekanik Değişimler Sonlu Elemanlar Analiz Çalışması

Halil ATMACA

Temas Basınç Sensörü Kalibrasyonu Ve Kalibrasyon Eğrilerinin Karşılaştırılması

İbrahim Mutlu, Levent Buluç, M. Sefa Müezzinoğlu, M. Yavuz Çırpıcı, Yasin Kişioğlu

Duruş Ve Göz Pozisyonunun İnsandaki Isırma Kuvvetine Etkileri: Deneysel Bir Çalışma

Altay TABANCACI, Gözde YORDANLI, K. Şefik DEMİRSOY, M. Güney TÖKE, Hamza ERDOĞAN, Mehmet YETMEZ

İnsan Bacak Hareketleri İçin Prototip Dış İskelet Robotik Sisteminin Mekanik Tasarımı Ve Hareket Verilerinin Yapay Sinir Ağları İle Elde Edilmesi

Evren Meltem TOYGAR, Ahmet ÖZKURT, Zeki KIRAL, Mehmet ÇAKMAKÇI, Binnur Gören KIRAL, Yavuz ŞENOL, Taner AKKAN, Yusuf ARMAN, Tolga OLCAY, Necati Mutlu DAĞHAN, Murat KARAGÖZ

Hastane Malzemelerinin Sağlık Çalışanlarının Postürüne Etkileri

Erkan ALP, Mehmet BOZKURT, İbrahim BAŞÇİFTÇİ

Plaklı Bir Damar İle Nıtınol Stent Etkileşimin Sonlu Elemanlar Yöntemiyle İncelenmesi

Recep GÜNEŞ, Ömer ÇAM, M. Kemal APALAK

Servikal Omurga Aksiyel Rotasyon Gonyometre Dizaynı

Emin Ulaş Erdem, Filiz Can

Yayılı Yükleme Etkisindeki Üç Boyutlu İnsan Kalça Ekleminin Sonlu Elemanlar Yöntemiyle İncelenmesi

Mehmet Emin Çetin, Hasan Sofuoğlu

İnsan Uyluk Kemiği Ve Kalça Protezinin Gerilme Ve Deplasman Davranışının Kıyaslanması

Fatih ATİK, Arif ÖZKAN, İlyas UYGUR