Effect of Colored Absorbers on the Performance of a Built-In-Storage Type Solar Water Heater

Effect of Colored Absorbers on the Performance of a Built-In-Storage Type Solar Water Heater

Four built-in-storage solar water heaters (BSWH) of equal volume, equal projected area are tested simultaneously under identical working conditions for their performance comparison in terms of efficiency and heat energy absorb ability. Three of the heaters of BSWH are painted with three different colors (black, blue and red brown) and one is left colorless. The BSWH with different colors are used to heat 138 liters of water.  Maximum temperature of water is achieved while the heater is painted black. In the month of March, temperature of water is achieved 54­0C for black absorber absorbing 542 W/m2, 500C for blue absorber absorbing 448 W/m2, 430C for red brown absorber absorbing 341 W/m2and 41­0C for colorless absorber absorbing 336 W/m2. Monthly average efficiency of BSWH with black absorber is 57% in February and 56.5% in March, with blue absorber is 53% in February and 50% in March, with red brown absorber is 41% in February and 40% in March and with colorless absorber is 35% in February and 35% in March respectively.

___

  • H. C. Hottel and B. B. Woertz, the Performance of Flat- Plate Solar Heat Collectors. Trans. ASME, pp. 91-104, Feb. 1942.
  • Ecevit, A.Al-shariah, A.M. and Apaydin, A Comparative Evaluation of the Performance three Built-in-Storage type solar water heaters. Solar Energy, Vol.44, pp. 23, 1990.
  • Y.Tripanagnostopoulos, M.Soulotis and TH. Nousia, Solar Collectors with Colored Absorbers. Solar Energy, Vol.68, pp.343-35, 2000.
  • Hamid, A.K.M.A and Akhanda, M.A.R, Performance Study of a Built-in-Storage type solar water heater at Dhaka, Bangladesh. Proceeding of the AISEC-5, Bahrain, November 13-16, 1995, Vol.3, pp.105-110.
  • Akhanda, M.A.R, Chowdhury and Murad, H.M, Comparison of collector-cum-storage solar water heaters having flat and vee corrugated absorber plates. Second International Conference on Energy Research and Development November 5-7 2001. KUWAIT, pp. 743-751,
  • RajibulAlam, An experimental study to compare performance between a Built-in-Storage type solar water heater (BSWH) and a natural flow type solar water heater. B.Sc. Engg. Thesis, MCE Department, IUT 2002.
  • Das N., Feroz C.M., Effect of Absorber Plate Geometry on the performance of collector cum storage type Solar Water Heater. M.Sc. Thesis, ME Department, BUET, Dhaka, 2000.
  • Mohamed. H. Al-Nahhal, Effect of Boosters on the Performance of a Built-in-Storage Type Solar Water Heater. M.Sc. Engg. Thesis, MCE Department, IUT 2003.
  • Khaled. M.A. Nakoa, Effect of Colored Absorbers on the Performance of a Built-In-Storage Type Solar Water Heater.M.Sc. Engg. Thesis, MCE Department, IUT 2006.