Determination of Bisphenol a with Poly (p-Aminobenzoic Acid) Modified Gold Electrode by Using Differential Pulse Voltammetry
Determination of Bisphenol a with Poly (p-Aminobenzoic Acid) Modified Gold Electrode by Using Differential Pulse Voltammetry
Bisphenol A (BPA) is important matter in chemical industry used in the produce of some foodcontact materials such as plastics, adhesives and coatings. But BPA has also some toxic effectsfor human endocrine system and environment. Therefore, novel sensitive and selective methodsfor determination the level of BPA in environmental, medical samples and foods newmeasurement methods need to be developed. A novel, sensitive, simple and cheapelectrochemical sensor based on poly (p-aminobenzoic acid) p(p-ABA) modified gold electrode(AuE) was developed for the measurement of BPA in water samples. Firstly, AuEs were modifiedwith polymerization of the p-amino benzoic acid as a monomer by using bulk electrolysis in 0.01M HCl at -250 mV. Then the electrochemical oxidation of BPA carried out in 0.1 M phosphatebuffer solution (PBS) pH=6 on p(p-ABA) modified AuE. The effects of various electrochemicalparameters, such as scan rate, electroyte type and electrolyte pH were examined. Differentialpulse voltammetry (DPV) was used as an ideal analytical method for the qualitative andquantitative detect of BPA in water samples. The developed electrochemical sensor has linearsignal to BPA in the range of 2–100 μM. Prepared electrode was showed the limit of detection(LOD) of 0.26 µM and R2 of 0.999. Additionally, the developed sensor s used to determinationthe BPA in bottled drinking water sold in Turkish markets by using DPV, and obtains satisfactoryresults. The recovery values of the bottle water samples in the freezer, at room temperature andin the car were calculated as 102.22%, 104.68% and 106.06% respectively.
___
- Cao, X.L., Dufresne, G., Belısle, S., Clement, G., Falıckı, M., Beraldın and F., Rulıbıkıye, A., “Levels
of bisphenol A in canned liquid infant formula products in Canada and dietary intake estimates”, J.
Agric. Food Chem., 56: 7919–7924, (2008).
- Ferrer, E., Santoni, E., Vittori, S., Font, G., Manes, J. and Sagratini, G., “Simultaneous determination
of bisphenol A, octylphenol, and nonylphenol by pressurised liquid extraction and liquid
chromatography–tandem mass spectrometry in powdered milk and infant formulas”, Food Chem. 126:
360–367, (2011).
- Li, Y., Wang, H., Yan, B. and Zhang, H., “An electrochemical sensor for the determination of
bisphenol A using glassy carbon electrode modified with reduced graphene oxide-silver/poly-L-lysine
nanocomposites”, J. Electroanal. Chem., 805: 39-46, (2017).
- Wang, W., Abualnaja, K.O., Asimakopoulos, A.G., Covaci, A., Gevao, B., Johnson-Restrepo, B.,
Kumosani, T.A., Malarvannan, G., Minh, T.B., Moon, H., Nakata, H., Sinha, R.K. and Kannan, K.,
“A comparative assessment of human exposure to tetrabromobisphenol A and eight bisphenols
including bisphenol A via indoor dust ingestion in twelve countries”, Environ. Int., 83: 183-191,
(2015)
- Shelnutt S., Kind J.and Allaben W., “Bisphenol A: Update on newly developed data and how they
address NTPs 2008 finding of Some Concern”, Food Chem. Toxicol., 57: 284–295, (2013).
- Wang, W., Tang, J., Zheng, S., Ma, X., Zhu, J., Li, F.and Wang, J., “Electrochemical determination
of bisphenol A at multi-walled carbon nanotubes/poly(crystal violet) modified glassy carbon
electrode”, Food Anal. Methods, 10: 3815-3824, (2017).
- Biedermann-Brem, S. and Grob, K., “Release of Bisphenol-A from polycarbonate baby bottles: water
hardness as the most relevant factor”, Eur. Food Res. Technol., 228: 679-684, (2009).
- Kuo, H.W. and Ding, W.H., “Trace determination of bisphenol A and phytoestrogens in infant
Formula powders by gas chromatography-mass spectrometry”, J. Chromatogr A, 1027: 67–74, (2004).
- Alkasir, R.S., Ganesana, M., Won, Y.H., Stanciu, L. and Andreescu, S., “Enzyme functionalized
nanoparticles for electrochemical biosensors: a comparative study with applications for the detection
of bisphenol A”, Biosens. Bioelectron., 26: 43-49, (2010).
- Ballesteros-Gómez, A., Rubio, S. and Pérez-Bendito, D., “Analytical methods for the determination
of bisphenol A in food”, J. Chromatogr A, 1216: 449-469, (2009).
- Lee, H.B. and Peart, T.E., “Determination of bisphenol A in sewage effluent and sludge by solid-phase
and supercritical fluid extraction and gas chromatography/mass spectrometry”, J. AOAC Int., 83: 290-
297, (2000).
- Li, D., Park, J. and Oh, J.R., “Silyl derivatization of alkylphenols, chlorophenols, and bisphenol A for
simultaneous GC/MS determination”, Anal. Chem., 73: 3089-3095, (2001).
- Yoshimura, Y., Brock, J. W., Makino, T. and Nakazawa, H., “Measurement of bisphenol A in human
serum by gas chromatography/mass spectrometry”, Anal. Chim. Acta, 458: 331–336, (2002).
- Khedr, A., “Optimized extraction method for LC–MS determination of bisphenol A, melamine and
di(2-ethylhexyl) phthalate in selected soft drinks, syringes, and milk powder”, J. Chromatogr. B, 930:
98-103, (2013).
- Molina-García, L., Fernández-de Córdova, M.L. and Ruiz-Medina, A., “Analysis of Bisphenol A in
milk by using a multicommuted fluorimetric sensor”, Talanta, 96: 195–201, (2012).
- Wang, J.Y., Su, Y.L., Wu, B.H. and Cheng, S.H., “Reusable, electrochemical sensor for bisphenol A
based on ionic liquid functionalized conducting polymer platform”, Talanta, 147:103-110, (2016).
- Sungur, Ş., Köroğlu, M. and Ozkan, A., “Determination of bisphenol a migrating from canned food
and beverages in markets”, Food Chem., 142: 87-91, (2014).
- Sajiki, J., Takahashi, K. and Yonekubo, J., “Sensitive method for the determination of bisphenol a in
serum using two system of highperformance liquid chromatography”, J. Chromatogr. B, 736: 255–
261, (1999).
- Wang, S.H., Wei, X.T., Du, L.Y. and Zhuang, H.S., “Determination of bisphenol a using a flow
injection inhibitory chemiluminescence method”, Luminescence, 20: 46-50, (2005).
- Li, Z., Ruan, M., Du, L., Wen, G., Dong, C. and Li, H.W., “Graphene nanomaterials supported
palladium nanoparticles as nanocatalysts for electro-oxidation of methanol”, J. Electroanal. Chem.,
805: 47-52, (2017).
- Rebocho, S., Cordas, C.M., Viveiros, and R., Casimiro, T., “Development of a ferrocenyl-based MIP
in supercritical carbon dioxide: Towards an electrochemical sensor for bisphenol A”, J. Supercrit.
Fluid., 135: 98–104, (2018).
- Yin, H., Zhou, Y., Ai, S., Han, R., Tang, T. and Zhu, L., “Electrochemical behavior of bisphenol A at
glassy carbon electrode modified with gold nanoparticles, silk fibroin, and PAMAM dendrimers”,
Microchim. Acta 170: 99-105, (2010).
- Yu, X.W., Chen, Y.K., Chang, L.P., Zhou, L., Tang, F.X. and Wu, X.P., “β-cyclodextrin noncovalently
modified ionic liquid-based carbon paste electrode as a novel voltammetric sensor for
specific detection of bisphenol A”, Sensor Actuat. B, 186:648–656, 2013).
- Ren, J., Kang, T.F., Xue, R., Ge, C. and Cheng, S., “Biosensor based on a glassy carbon electrode
modified with tyrosinase immmobilized on multiwalled carbon nanotubes, Microchim. Acta, 174:303-
309, (2011)
- Pereira, G.F., Andrade, L.S., Rocha-Filho, R.C., Bocchi, N. and Biaggio, S.R., “Electrochemical
determination of bisphenol a using a boron-doped diamond electrode”, Electrochim. Acta, 82: 3-8
(2012).
- Niu, X.L., Yang, W., Wang, G.Y., Ren, J., Guo, H. and Gao, J.Z., “A novel electrochemical sensor of
bisphenol a based on stacked grapheme nanofibers/gold nanoparticles composite modified glassy
carbon electrode”, Electrochim. Acta, 98: 167-175, (2013).
- Lin, Y.Q., Liu, K.Y., Liu, C.Y., Yin, L., Kang, Q., Li, L.B. and Li, B., “Electrochemical sensing of
bisphenol a based on polyglutamic acid/amino-functionalised carbon nanotubes nanocomposite”,
Electrochim. Acta, 133: 492-500, (2014).
- Zhu, L.L., Cao, Y.H. and Cao, G.Q., “Electrochemical sensor based on magnetic molecularly
imprinted nanoparticles at surfactant modified magnetic electrode for determination of bisphenol A”,
Biosens Bioelectron., 54: 258-261 (2014).
- Zhang, Y.X., Cheng, Y.X., Zhou, Y.Y., Li, B.Y., Gu, W., Shi, X.H. and Xian, Y.Z., “Electrochemical
sensor for bisphenol a based on magnetic nanoparticles decorated reduced graphene oxide”, Talanta,
107: 211-218, (2013).
- Kaur, B., Satpati, B. and Srivastava, R., “ZrO2 supported Nano-ZSM-5 nanocomposite material for
the nanomolar electrochemical detection of metol and bisphenol A”, RSC Adv., 6: 65736-65746,
(2016).
- Reza, K.K., Ali, M.A., Srivastava, S., Agrawal, V.V. and Biradar, A.M., “Tyrosinase conjugated
reduced graphene oxide based biointerface for bisphenol a sensor”, Biosens Bioelectron., 74: 644-
651, (2015).
- Jing, P., Zhang, X.M., Wu, Z.X., Bao, L., Xu, Y.L., Liang, C.Z. and Cao, W.Q., “Electrochemical
sensing of bisphenol a by graphene-1-butyl-3-methylimidazolium hexafluorophosphate modified
electrode”, Talanta, 141: 41-46, (2015).
- Qi P., Wang J., Wang X., Wang Z., Xu H., Di S., Wang Q. and Wang X., “Sensitive and selective
detection of the highly toxic pesticide carbofuran in vegetable samples by a molecularly imprinted
electrochemical sensor with signal enhancement by AuNPs”, RSC Adv., 8: 25334-25341, (2018).
- Xu, F., Gao, M., Wang, L., Shi, G., Zhang, W., Jin, L. and Jin, J., “Sensitive determination of
dopamine on poly(aminobenzoic acid) modified electrode and the application toward an experimental
Parkinsonian animal model”, Talanta, 55: 329-336, (2001).
- Ndlovu, T., Arotiba, O.A., Sampath, S., Krause, R.W. and Mamba, B.B., “An Exfoliated GraphiteBased
Bisphenol A Electrochemical Sensor”, Sensors, 12, 11601-11611, (2012).
- Silva, C.T.P., Veregue, F.R. Aguiar, L.W., Meneguin, J.G., Mois_es, M.P., F_avaro, S.L.,
Radovanovic, E., Girotto, E.M. and Rinaldi, A.W., “AuNp@MOF composite as electrochemical
material for determination of bisphenol A and its oxidation behavior study”, New J. Chem., 40: 8872-
8877 (2016).