Non-Linear Eddy Current Loss and Thermal Analysis on Transformer Cover

Non-Linear Eddy Current Loss and Thermal Analysis on Transformer Cover

High current conductors of transformers cause to produce losses and thermal problems in theirtank cover. Finite Difference (FD) Method (FDM) magnetic analysis is used to find out an exactestimation of the magnetic field and the losses near the bushings in the transient solution,considering the non-linear magnetic permeability of the cover plate, because FDM is moreflexible to deal with the nonlinear constitutive law and easy-to-be implemented especially in thecase of simple geometry. Finite Element Method (FEM) thermal analysis is used to determinethe plate temperature based on magnetic FD analysis, taking account non-linear heat fluxboundary condition. A calibration procedure is used between the analyses to ensure the precisionof assumptions. The reliability of the technique, confirmed by experimental and FEM results.

___

  • Kulkarni, S. V., Olivares, J. C., Perez, R. E., Lakhiani, V. K., and Turowski, J., “Evaluation of eddy current losses in the cover plates of distribution transformers”, IEE Proceedings - Science, Measurement and Technology, 151(5): 313-318, (2004).
  • Maximov, S., Perez, R. E., Adame, S. M., Olivares, J. C., and Littlewood, E. C., “Calculation of nonlinear electromagnetic fields in the steel wall vicinity of transformer bushings”, IEEE Transactions on Magnetics, 51(6): (2015).
  • Olivares, J. C., Georgilakis, P. S., and Ocon-Valdez, R., “A review of transformer losses”, Electric Power Components and Systems, 37(9): 1046-1062, (2009).
  • Kulkarni, S. V. and Khaparde, S., Transformer engineering: design, technology and diagnostics, CRC Press, (2016).
  • Turowski, J. and Pelikant, A., “Eddy currents losses and hot-spot evaluation in cover plates of power transformers”, IEE Proceedings-Electric Power Applications, 144(6): 435-440, (1997).
  • Turowski, J., Elektrodynamika techniczna 2 nd ed., WNT, Warszawa, Poland, (1993)
  • Olivares, J. C., Perez, R. E., Kulkarni, S. V., Leon, F. D., and Vega, M. A. V., “2D finite-element determination of tank wall losses in pad-mounted transformers”, Electric Power Systems Research, 71: 179-185, (2004).
  • Zahedi, M. Z. and Iskender, I., “3D FEM optimal design of transformer cover plates to decrease stray losses and hot spot temperature”, International Journal on Technical and Physical Problems of Engineering (IJTPE), 8(3): 56-60, (2016).
  • Olivares, J. C., Perez, R. E., Kulkarni, S. V., Leon, F. D., Vasquez, E. M., and Anaya, O. H., “Improved insert geometry for reducing tank-wall losses in pad-mounted transformers”, IEEE Transactions on Power Delivery, 19(3): 1120-1126, (2004).
  • Maximov, S., Olivares-Galvan, J. C., Magdaleno-Adame, S., Escarela-Perez, R., and CamperoLittlewood, E., “New analytical formulas for electromagnetic field and eddy current losses in bushing regions of transformers”, IEEE Transactions on Magnetics, 51: (2015).
  • Del Vecchio, R. M., Del Vecchio, R., Poulin, B., Feghali, P. T., Shah, D. M., and Ahuja, R., Transformer design principles with applications: with applications to core-form power transformers 3 rd ed, CRC press, (2017).
  • Zahedi, M. Z. and Iskender, I., “FDM electromagnetic analysis in bushing regions of transformer”, International Journal on Technical and Physical Problems of Engineering (IJTPE), 10(34): 27-33, Mar. (2018).
  • Lopez-Fernandez, X. M., Penabad-Duran, P., Turowski, J., and Ribeiro, P. M., “Non-linear heating hazard assessment on transformer covers and tank walls”, Przegląd Elektrotechniczny (Elect. Rev.), 88(7b): 28–31, (2012).
  • Vecchio, R. M. D. and Ahuja, R., “Analytic nonlinear correction to the impedance boundary condition”, IEEE Transactions on Magnetics, 49(12): 5687–5691, (2013).
  • Fernandez, X. M. L., Duran, P. P., and Turowski, J., “Three dimensional methodology for the overheating hazard assessment on transformer covers”, IEEE Transactions on Industry Applications, 48: 1549-1555, (2012).
  • Durana, P. P., Fernandez, X. M. L., and Turowski, J., “3D non-linear magneto-thermal behavior on transformer covers”, Electric Power Systems Research, 121: 333-340, (2015).
  • Maximov, S., Escarela-Perez, R., Olivares-Galvan, J. C., Guzman, S. J., and Campero-Littlewood, E., “New analytical formula for temperature assessment on transformer tanks”, IEEE Transactions on Power Delivery, 31(3): 1122-1131, (2016).
  • Sadiku, M. N., Elements of electromagnetics, Oxford university press, (2014).
  • “User’s Guide - Maxwell 3D/ANSYS Maxwell 15 ed.”, ANSYS Inc., Canonsburg, PA, USA, (2012).
  • Kumbhar, G. B., Mahajan, S. M., and Collett, W. L., “Reduction of loss and local overheating in the tank of a current transformer”, IEEE Transactions on Power Delivery, 25(4): 2519-2525, (2010).
  • Sadiku, M. N. O., Numerical techniques in electromagnetics, CRC Press, New York, (2001).
  • Gillott, D. H. and Calvert, J. F., “Eddy current loss in saturated solid magnetic plates, rods, and conductors”, IEEE Transactions on Magnetics, 1(2): 126–137, (1965).
  • Holman, J. P., Heat transfer, McGraw-Hill, New York, 1-5, (2010).
  • Internet: Heat distribution in a circular cylindrical rod, In MathWorks Online. https://www.mathworks.com/help/pde/examples/heat-distribution-in-a-circular-cylindricalrod.html?s_tid=srchtitle, (2018).
  • Internet: Nonlinear heat transfer in a thin plate, In MathWorks Online. https://www.mathworks.com/help/pde/examples/nonlinear-heat-transfer-in-a-thinplate.html?searchHighlight=Nonlinear%20Heat%20Transfer%20In%20a%20Thin%20Plate&s_tid= doc_srchtitle, (2018).
  • Zahedi, M. Z. and Iskender, I., "Nonlinear Adaptive MagnetoThermal Analysis at Bushing Regions of a Transformers Cover Using Finite Difference Method", Journal of Thermal Science and Engineering Applications, 11(1): 011010-1 - 011010-8, (2018).