Attenuation Effect of Sample Container in Radioactivity Measurement by Gamma-ray Spectroscopy

Attenuation Effect of Sample Container in Radioactivity Measurement by Gamma-ray Spectroscopy

The measurement of radioactivity in environmental samples containing natural radionuclides such as 238U, 232Th, and 40K in gamma-ray spectrometry is the most common application. One of the most widely used sample containers for environmental radioactivity measurements is volumetric sample containers of certain sizes in cylindrical geometry. These cylindrical containers can be made of materials with different densities and thicknesses. In this intention, in this study, the effect of the sample container, which is one of the many parameters affecting the detector efficiency, was investigated. For this purpose, acrylic and polypropylene materials with of different densities were examined. IAEA RGU-1, IAEA-RGTh-1 and IAEA-RGK-1 standards containing uranium, thorium and potassium environmental radionuclides analyzed in gamma-ray spectrometric measurements were used as samples for these sample containers with different densities. Additionally, since the spectra in cylindrical geometry are taken by placing them on the detector endcap, the effect of the bottom thickness was investigated by changing the bottom thickness of these materials. Different material and bottom thickness evaluations were made using PHITS and GESPECOR Monte Carlo simulation programs. Compatible results were obtained with a difference of <5% between the PHITS and GESPECOR programs. From the outcome of this study, it can be concluded that when choosing the container material, the density should be as low as possible and especially the bottom thickness should be thin.

___

  • Abd El Gawad, K., Zhijian, Z., & Hazzaa, M. H. (2020). Improving the analysis performance of gamma spectrometer using the Monte Carlo code for accurate measurements of uranium samples. Results in Physics, 17, 103145. doi:10.1016/j.rinp.2020.103145
  • Azbouche, A., Belgaid, M., & Mazrou, H. (2015). Monte Carlo calculations of the HPGe detector efficiency for radioactivity measurement of large volume environmental samples. Journal of Environmental Radioactivity, 146, 119-124. doi:10.1016/j.jenvrad.2015.04.015
  • Berger, M. J., Hubbell, J. H., Seltzer, S. M., Chang, J., Coursey, J. S., Sukumar, R., Zucker, D. S., & Olsen, K. (2010). XCOM: Photon Cross Section Database. Gaithersburg, MD. doi:10.18434/T48G6X
  • Bölükdemir, M. H., Uyar, E., Aksoy, G., Ünlü, H., Dikmen, H., & Özgür, M. (2021). Investigation of shape effects and dead layer thicknesses of a coaxial HPGe crystal on detector efficiency by using PHITS Monte Carlo simulation. Radiation Physics and Chemistry, 189, 109746. doi:10.1016/j.radphyschem.2021.109746
  • Gilmore, G. (2008). Practical Gamma-Ray Spectrometry. John Wiley and Sons.
  • Guerra, J. G., Rubiano, J. G., Winter, G., Guerra, A. G., Alonso, H., Arnedo, M. A., Tejera, A., Martel, P., & Bolivar, J. P. (2018). Modeling of a HPGe well detector using PENELOPE for the calculation of full energy peak efficiencies for environmental samples. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 908, 206-214. doi:10.1016/j.nima.2018.08.048
  • Hirayama, H., Namito, Y., Bielajew, A. F., Wilderman, S. J., & Nelson, W. R. (2006). The EGS5 Code System. Technical Report (SLAC-R-730) (KEK 2005-8), Stanford Linear Accelerator Center, Menlo Park, California.
  • Knoll, G. F. (2010). Radiation Detection and Measurement. John Wiley and Sons.
  • Lépy, M.-C., Altzitzoglou, T., Anagnostakis, M. J., Arnold, D., Capogni, M., Ceccatelli, A., De Felice, P., Dersch, R., Dryak, P., Fazio, A., Ferreux, L., Guardati, M., Han, J. B., Hurtado, S., Karfopoulos, K. L., Klemola, S., Kovar, P., Lee, K. B., Ocone, R., … Vidmar, T. (2010). Intercomparison of methods for coincidence summing corrections in gamma-ray spectrometry. Applied Radiation and Isotopes, 68(7-8), 1407-1412. doi:10.1016/j.apradiso.2010.01.012
  • Lépy, M. C., Thiam, C., Anagnostakis, M., Galea, R., Gurau, D., Hurtado, S., Karfopoulos, K., Liang, J., Liu, H., Luca, A., Mitsios, I., Potiriadis, C., Savva, M. I., Thanh, T. T., Thomas, V., Townson, R. W., Vasilopoulou, T., & Zhang, M. (2019). A benchmark for Monte Carlo simulation in gamma-ray spectrometry. Applied Radiation and Isotopes, 154, 108850. doi:10.1016/j.apradiso.2019.108850
  • Modarresi, S. M., Masoudi, S. F., & Karimi, M. (2017). A method for considering the spatial variations of dead layer thickness in HPGe detectors to improve the FEPE calculation of bulky samples. Radiation Physics and Chemistry, 130, 291-296. doi: 10.1016/j.radphyschem.2016.08.020
  • NIST, (2022). Composition of material. (Accessed: 01/10/2022) URL (https://physics.nist.gov/cgi-bin/Star/compos.pl)
  • Sato, T., Iwamoto, Y., Hashimoto, S., Ogawa, T., Furuta, T., Abe, S.-I., Kai, T., Tsai, P.-E., Matsuda, N., Iwase, H., Shigyo, N., Sihver, L., & Niita, K. (2018). Features of Particle and Heavy Ion Transport code System (PHITS) version 3.02. Journal of Nuclear Science and Technology, 55(6), 684-690. doi:10.1080/00223131.2017.1419890
  • Sima, O., De Vismes Ott, A., Dias, M. S., Dryak, P., Ferreux, L., Gurau, D., Hurtado, S., Jodlowski, P., Karfopoulos, K., Koskinas, M. F., Laubenstein, M., Lee, Y. K., Lépy, M. C., Luca, A., Menezes, M. O., Moreira, D. S., Nikolič, J., Peyres, V., Saganowski, P., … Yucel, H. (2020). Consistency test of coincidence-summing calculation methods for extended sources. Applied Radiation and Isotopes, 155, 108921. doi:10.1016/j.apradiso.2019.108921
  • Sima, O., & Arnold, D. (2002). Transfer of the efficiency calibration of Germanium gamma-ray detectors using the GESPECOR software. Applied Radiation and Isotopes, 56(1-2), 71-75. doi:10.1016/S0969-8043(01)00169-5
  • Sima, O., Arnold, D., & Dovlete, C. (2001). GESPECOR: a versatile tool in gamma-ray spectrometry. Journal of Radioanalytical and Nuclear Chemistry, 248(2), 359-364. doi:10.1023/a:1010619806898
  • Stríbrnský, B., Hinca, R., Farkas, G., Petriska, M., & Slugeň, V. (2022). Modeling and Optimization of HPGe Detector GC0518 Using MCNP5 Code. Radiation Protection Dosimetry, 198(9-11), 704-711. doi:10.1093/rpd/ncac123
  • Trang, L. T. N., Chuong, H. D., & Thanh, T. T. (2021). Optimization of p-type HPGe detector model using Monte Carlo simulation. Journal of Radioanalytical and Nuclear Chemistry, 327(1), 287-297. doi:10.1007/s10967-020-07473-2
  • Uyar, E., & Bölükdemir, M. H. (2022). The effect of front edge on efficiency for point and volume source geometries in p-type HPGe detectors. Nuclear Engineering and Technology, 54(11), 4220-4225. doi:10.1016/j.net.2022.06.009
  • Yücel, H., Solmaz, A. N., Köse, E., & Bor, D. (2010). Methods for spectral interference corrections for direct measurements of 234U and 230Th in materials by gamma-ray spectrometry. Radiation Protection Dosimetry, 138(3), 264-277. doi:10.1093/rpd/ncp239
Gazi University Journal of Science Part A: Engineering and Innovation-Cover
  • Yayın Aralığı: 4
  • Başlangıç: 2013
  • Yayıncı: Gazi Üniversitesi, Fen Bilimleri Enstitüsü
Sayıdaki Diğer Makaleler

Investigation and Development of Polarographic Method for Pb (II) and Cd (II) Analyses in Oils

Şükrü KALAYCI, Sinan Mithat MUHAMMET, Bekir Sıtkı CEVRİMLİ

Machine Learning Techniques for the Classification of IoT-Enabled Smart Irrigation Data for Agricultural Purposes

Aamo IORLİAM, Sylvester BUM, Iember S. AONDOAKAA, Iveren Blessing IORLIAM, Yahaya SHEHU

Attenuation Effect of Sample Container in Radioactivity Measurement by Gamma-ray Spectroscopy

Esra UYAR

Effects of Different Culture Media Compositions on In Vitro Micropropagation from Paradox Walnut Rootstock Nodes

Cem DİRLİK, Hacer KANDEMİR, Nurberat ÇETİN, Senem ŞEN, Begüm GÜLER, Aynur GÜREL

Comparison of Experimental and Monte Carlo Efficiencies of 0.5g/cc Epoxy Matrix Marinelli Source with Multiple Radioactive Nuclides

Gülper AKSOY, Hasan ÜNLÜ, Nilgün ORHAN, Mustafa Hicabi BÖLÜKDEMİR

Investigation of Microstructure and Tribological behavior of WE43/nano B4C Composites Produced by Spark Plasma Sintering

Ufuk TAŞCI, Bulent BOSTAN

Characterization of Hot Extruded Hybrid Composites Al 2024 Metal Matrix Reinforced with TiO2 and ZrO2

Ayşenur PEKTAŞ, Okan Can EBETÜRK, Uğur GÖKMEN

Experimental Investigation of Hydro-Mechanical Soil Properties of a Slope Failure

Seda DURUKAN, Ender BAŞARI

Sample Size Estimation of Nonparametric Tests with Ordered Alternatives for Longitudinal Data in Randomized Complete Block Designs

Melike BAHÇECİTAPAR, Hatice Tül Kübra AKDUR

Effect of Diluent Amount on Properties of Porous NiAl

Gülizar SARIYER, Hasan Erdem ÇAMURLU