Shaping Efficiency of WaveOne Gold and One Curve in Simulated J-Shaped Root Canals

To evaluate the shaping efficiency of WaveOne Gold (WOG; Dentsply Sirona, Ballaigues, Switzerland)and One Curve (OC;Micro-Mega, Besancon, France) in J-shaped resin blocks.Forty simulated J-shaped root canals with 0.15 mm apical diameters and 2 %taper were divided into two groups (n=20) as follows; WOGG/WOG (25.07) group (glide path was created with WaveOne Gold Glider) and OneG/OC (25.06) (glide path was created with One G) group. The pre-and post-instrumentation images were taken, and the transportation value (TV), centering ability (CA) and the total amount of resin removed (TRR) were calculated by using the superimposition of the images. These parameters calculated with Image J Software Program based on 18 reference points with 1-mm intervals of the canal. The data were analyzed with Kruskal-Wallis and than Dunn's multiple comparison tests. The significance level was set at P≤ .05.There was no statistically significant difference among OG/OC and WOG/WOGG groups' apical (points 1-3), middle (points 4-6), and coronal (points 7-9) sections in terms of both TV and TRR. The centering ability of the instruments was decreased in the curvature part (middle section) of the canals. While WOG group showed better centering ability at points 6-7, OC group exhibited better result at point 2.It was shown that WaveOne Gold and One Curve, which are single-file systems, could be used safely in J-shaped root canals with their glide path files.

___

1.Yared G. Canal preparation using only one Ni-Ti rotary instrument: preliminary observations. Int Endod J 2008; 41: 339-344.

2.Letters S, Smith AJ, McHugh S, Bagg J. A study of visual and blood contamination on reprocessed endodontic files from general dental practice. Br Dent J 2005; 199: 522-525

3.Webber, J. Shaping canals with confidence: WaveOne GOLD single-file reciprocating system.Roots2015; 1: 34-40.

4.Bürklein S, Schäfer E. Apically extruded debris with reciprocating single-file and full-sequence rotary instrumentation systems. Journal of endodontics 2012; 38:850-852.

5.Staffoli S, Grande NM, Plotino G, et al. Influence of environmental temperature, heat-treatment and design on the cyclic fatigue resistance of three generations of a single-file nickel–titanium rotary instrument. Odontol 2019; 107: 301-307.

6.Micro Mega. The One Curve Brochure. Availabla at: https://micro-mega.com/wp-content/uploads/2018/03/60301824-D_Brochure-One-Curve-EN_WEB.pdf. Accessed at 18.03.2020.

7.Micro Mega. The One G Brochure. Available at: https://micro-mega.com/wp-content/uploads/2018/03/OneG_EN1_15_web.pdf. Accessed at 18.03.2020.

8.Dentsply. Wave One Gold Brochure. Available at: https://www.dentsplysirona.com/content/dam/dentsply/pim/en_GB/Endodontics/Obturation/Paper_Points/WaveOne_Gold_Absorbent_Points/WaveOne%20GOLD%20Brochure%202015.pdfAccessed at 18.03.2020.

9.Vorster M, van de Vyver PJ, Paleker F. Canal Transportation and Centering Ability ofWaveOneGoldin Combination with and without Different Glide Path Techniques. J Endod2018; 44: 1430-1435.

10.Dhingra A, Kochar R, Banerjee S, Srivastava P. Comparative evaluation of the canal curvature modifications after instrumentation with One Shape rotary and Wave One reciprocating files.J Conserv Dent2014; 17: 138

11.Pedulla E, Leanza G, La Rosa GRM, et al. Cutting efficiency of conventional and heat-treated nickel–titanium rotary or reciprocating glide path instruments. Int Endod J 2020; 53: 376-384.

12.Saleh AM, Gilani PV, Tavanafar S, Schafer E. Shaping Ability of 4 Different Single-file Systems in Simulated S-shaped Canals. J Endod 2015; 41: 548-552.

13.Özyürek T, Yılmaz K, Uslu G. Shaping ability of Reciproc, WaveOne GOLD, and HyFlex EDM single-file systems in simulated S-shaped canals. J Endod 2017;43:805-809.

14.Ates AA, Arıcan B, Işık V. Comparison of Shaping Ability of XP-Endo Shaper in Simulated J-Shaped Canals with Various Sizes. Journal of Research in Medical and Dental Science 2020;8:176-181.

15.Ersev H, Yilmaz B, Ciftçioğlu E, ÖzkarslI SF. A comparison of the shaping effets of 5 nickel-titanium rotary instruments in simulated S-shaped canals. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2010; 109: 86-93.

16.Beshkenadze E, Chipashvili N. Anatomo-morphological features of the root canal system in Georgian population–cone-beam computed tomography study.Georgian Med News2015;247: 7-14.

17.Di Giuseppe I,Di Giuseppe D, Malagnino VA, Silla EP, Somma F. Conditioning of root canal anatomy on static and dynamics of nickel-titanium rotary instruments. Giornale Italiano di Endodonzia2015; 29: 58-64.

18.Burklein S, Hinschitza K, Dammaschke T, Schafer E. Shaping ability and cleaning effectiveness of two single-file systems in severely curved root canals of extracted teeth: Reciproc and WaveOne versus Mtwo and ProTaper. Int Endod J 2012; 45: 449-641.

19.Türker SA, Koçak S, Kocak M, Saglam B. Effect of glide path preparation on apical debris extrusion of rotary and reciprocating single-file systems: OneShape versus WaveOne.Cumhuriyet Dent J2015; 18: 1-8.

20.Bürklein S, Benten S, Schäfer E. Shaping ability of different single‐file systems in severely curved root canals ofextracted teeth.Int Endod J2013; 46: 590-597.

21.Alovisi M, Cemenasco A, Mancini L, et al. Micro-CT evaluation of several glide path techniques and ProTaper Next shaping outcomes in maxillary first molar curved canals. Int Endod J 2017; 50: 387-397.

22.You S-Y, Kim H-C, Bae K-S, Baek SH, Kum KY, Lee W. Shaping ability of reciprocating motion in curved root canals: a comparative study with micro–computed tomography. J Endod 2011; 37: 1296-1300.

23.Ha J-H, Park S-S. Influence of glide path on the screw-in effect and torque of nickel-titanium rotary files in simulated resin root canals. Restor Dent Endod 2012;37:215.

24.Yilmaz A, Kucukay ES, Istektepe M, Sisli SN, Ersev H, Karagoz-Kucukay I. Comparison of the shaping ability of WaveOne Reciprocating files with or without glide path in simulated curved S-shaped root canals.J Int Soc Prev Community Dent 2017; 7: 13.

25.Muñoz E, Forner L, Llena C. Influence of operator's experience on root canal shaping ability with a rotary nickel-titanium single-file reciprocating motionsystem. J Endod 2014;40:547-550.

26.Shen Y, Haapasalo M. Three-dimensional analysis of cutting behavior of nickel-titanium rotary instruments by microcomputed tomography. J Endod 2008; 34: 606-610.
Eastern Journal of Medicine-Cover
  • ISSN: 1301-0883
  • Yayın Aralığı: 4
  • Başlangıç: 1996
  • Yayıncı: ERBİL KARAMAN
Sayıdaki Diğer Makaleler

Idiopathic Granulomatous Mastitis and Other Types of Mastitis; Comparison of Ultrasound Findings

Nurşen TOPRAK, Ali Mahir GÜNDÜZ

The Effects of Sugammadex On Coagulation In Pregnant Rats

Mehmet Emin KESKİN, Havva SAYHAN KAPLAN, Nurcin GULHAS, Yasemin BAYRAM, YILDIRAY BAŞBUĞAN

Effectiveness of Hounsfield Unit Values in the Differentiation of Malign and Benign Thyroid Nodules

Fatma DURMAZ, Mesut ÖZGÖKÇE

An Experimental Study That Investigates Effects of Atreleuton in Metabolic Syndrome

TEVFİK NOYAN, Sertaç Burhanettin AYHAN

Athletes´ Heart: QTC Dispersion and Speckle Tracking Echocardiography

Remzi SARIKAYA, Dilek GİRAY

Shaping Efficiency of WaveOne Gold and One Curve in Simulated J-Shaped Root Canals

Ayfer ATAV ATEŞ, Burçin ARICAN

Evaluation of Serum Levels of Trace Elements in Myeloproliferative Neoplasms: A Case-Control Study

Fatih YETİŞGİN, Ramazan ESEN, Mustafa BİLİCİ

Effects of Testicular Volume, Follicle Stimulating Hormone, Luteinizing Hormone and Presence of Varicocele On Successful Sperm Retrieval In Non-Obstructive Azoospermia

İrfan Şafak BARLAS, Lütfi TUNÇ, Ahmet Emin DOĞAN, Uğur COŞAR, Ender Cem BULUT

Assessment of Sleep Quality in Patients with Type 2 Diabetes Mellitus: A Case-control Study

Şemsinnur GÖÇER, Ramazan ÖNALAN, Tekin YILDIRIM, Yunus HACIMUSALAR

Drug-Drug Interactions In The Risky Population: Elderly, Urological Patients Admitted To The Intensive Care Unit

Muhammet Serdar BUĞDAY, Ersoy ÖKSÜZ