Total hip arthroplasty-related pelvic pseudotumor: Unusual presentation with hydronephrosis

Pseudotumors in the pelvis are due to the polyethylene wear of hip arthroplasty. They occurs mostly around the joint but may sometimes protrude into the pelvic area, causing various symptoms. We present a rare case of pelvic pseudotumor which becomes manifest with urinary obstruction in the presence of an asymptomatic hip joint.

___

Paprosky WG, Perona PG, Lawrence JM. Acetabular defect classiŞcation and surgical reconstruction in revision arthroplasty. A 6-year follow-up evaluation. J Arthroplast. 1994;9:33e44.

Willert HG, Semlitsch M. Reactions of the articular capsule to wear products of artiŞcial joint prostheses. J Biomed Mater Res. 1977;11:157e164.

Boynton EL, Henry M, Morton J, Waddell JP. The inflammatory response to particulate wear debris in total hip arthroplasty. Can J Surg. 1995;38:507e515.

Kesteris U, Jonsson K, Robertsson O, OnnerfEURalt R, Wingstrand H. Polyethylene wear and synovitis in total hip arthroplasty: a sonographic study of 48 hips. J Arthroplast. 1999;14:138e143.

Pandit H, Glyn-Jones S, McLardy-Smith P, et al. Pseudotumours associated with metal-on-metal hip resurfacings. J Bone Jt Surg Br. 2008;90:847e851.

Korkala O, Syrjanen KJ. Intrapelvic cyst formation after hip arthroplasty with a carbonŞbre-reinforced polyethylene socket. Arch Orthop Trauma Surg. 1998;118:113e115.

Mak KH, Wong TK, Poddar NC. Wear debris from total hip arthroplasty pre- senting as an intrapelvic mass. J Arthroplast. 2001;16:674e676.

Murgatroyd SE. Pseudotumor presenting as a pelvic mass: a complication of eccentric wear of a metal on polyethylene hip arthroplasty. J Arthroplast. 2012May;27;820(5):e1ee4. Epub 2011 Oct 22.

http://dx.doi.org/10.1016/j.arth.2011.09.008. 9. Iwamoto T, Ikari K, Momohara S. Pseudotumor from a metal-on-metal hip. J Rheumatol. 2011;38:2265.

Thienpont E, Vernaeve H. Reactive pelvic cyst following total hip arthroplasty. A case report. Acta Orthop Belg. 2003;69:292e294.

Beksac B, Tozun R, Baktiroglu S, Sener N, Gonzalez Della Valle A. Extravascular compression of the femoral vein due to wear debris-induced iliopsoas bursitis: a rare cause of leg swelling after total hip arthroplasty. J Arthroplast. 2007;22: 453e456.

Shilt JS, Rozencwaig R, Wilson MR. Pelvic mass secondary to polyethylene and titanium alloy wear debris resulting in recurrent deep vein thrombosis. J Arthroplast. 1997;12:946e949.

Schuh A, Werber S, Zeiler G, Craiovan B. Femoral nerve palsy due to excessive granuloma in aseptic cup loosening in cementless total hip arthroplasty. Zen- tralbl Chir. 2004;129:421e423.

Leigh W, O\'Grady P, Lawson EM, Hung NA, Theis JC, Matheson J. Pelvic pseu- dotumor: an unusual presentation of an extra-articular granuloma in a well- Şxed total hip arthroplasty. J Arthroplast. 2008;23:934e938.

Hananouchi T, Saito M, Nakamura N, Yamamoto T, Yonenobu K. Huge pelvic mass secondary to wear debris causing ureteral obstruction. J Arthroplast. 2005;20:946e949.
Acta Orthopaedica et Traumatologica Turcica-Cover
  • ISSN: 1017-995X
  • Başlangıç: 2015
  • Yayıncı: Türk Ortopedi ve Travmatoloji Derneği
Sayıdaki Diğer Makaleler

Safety of modiŞed Stoppa approach for Ganz periacetabular osteotomy: A preliminary cadaveric study

Mehmet ELMADAĞ, GÖKÇER UZER, FATİH YILDIZ, Hasan H CEYLAN, Mehmet A. ACAR

Comparison of the chondroprotective effect of a novel hydrogel compound and traditional hyaluronate on rat cartilage in a papain-induced osteoarthritis model

Erhan ŞÜKÜR, Canan TALU, Yunus Emre AKMAN, Esra CİRCİ, YUSUF ÖZTÜRKMEN, Tolga TÜZÜNER

Tibiotalocalcaneal arthrodesis by using proximal humeral locking plate

Devrim ÖZER, Avni İlhan BAYHAN, Abdi KESKİN, Seçkin SARI, Mehmet Akif KAYGUSUZ

Comment on: Measurement of the knee joint line in Turkish population (In reply)

Mahmut CAKAR

Efficacy of preoperative administration of single high dose intravenous tranexamic acid in reducing blood loss in total knee arthroplasty: A prospective clinical study

Turgut AKGÜL, MEHMET İLKE BÜGET, AHMET SALDUZ, İpek S. EDİPOĞLU, Mehmet EKİNCİ, Süleyman KÜÇÜKAY, CENGİZ ŞEN

Effects of two different degrees of lateral-wedge insoles on unilateral lower extremity load-bearing line in patients with medial knee osteoarthritis

BİLGE YILMAZ, Serdar KESKINBURUN, ÖZLEM KÖROĞLU, EVREN YAŞAR, Ahmet Salim GOKTEPE, Kamik YAZICIOĞLU

Total hip arthroplasty-related pelvic pseudotumor: Unusual presentation with hydronephrosis

Zeynep Gamze KILIÇOĞLU, ÖNDER İSMET KILIÇOĞLU, Mehmet Masum ŞİMŞEK

Effects of immobilization and whole-body vibration on rat serum TypeI collagen turnover

GÜRHAN DÖNMEZ, MAHMUT NEDİM DORAL, Senay SULJEVIC, MUSTAFA FEVZİ SARGON, Hasan BİLGİLİ, Haydar Ali DEMIREL

Restore a 9 mm diameter osteochondral defect with gene enhanced tissue engineering followed mosaicplasty in a goat model

Jun SUN, Xiao-kui HOU, Yu-xin ZHENG

The primary factor for suture conŞguration at rotator cuff repair: Width of mattress or distance from tear edge

ONUR HAPA, AHMET KARAKAŞLI, ONUR BAŞCI, Hakan CİCİ, BERİVAN ÇEÇEN