The efficacy of a through-the-scope sodium phosphate solution with completion colonoscopy on the same day as a salvage option for inadequate bowel cleansing
The efficacy of a through-the-scope sodium phosphate solution with completion colonoscopy on the same day as a salvage option for inadequate bowel cleansing
Background/aim: The aim of this study was to investigate the efficacy of a through- the-scope sodium phosphate solution with completion colonoscopy on the same day as a salvage option for inadequate bowel preparation Materials and methods: All participants were instructed to eat a low residual diet for 3 days before the scheduled colonoscopy and a clear liquid diet 18 h before the colonoscopy. The patients were asked to take split doses of an oral sennoside solution at 1800 and 2200 in the evening before the colonoscopy. In cases of inadequate bowel preparation detected during routine colonoscopy, a sodium phosphate solution was administered through the scope on the day of the colonoscopy procedure. The degree of bowel cleansing was assessed by the Boston Bowel Preparation Scale (BPS: 0 9). Results: Almost excellent bowel cleansing was obtained with a statistically significant difference between the degree of bowel cleansing before and after the application of the sodium phosphate (Boston BPS: 5.48 ± 1.01 vs. 8.88 ± 0.33 respectively, P < 0.001). Conclusion: Through-the-scope sodium phosphate with completion colonoscopy on the same day was shown to be an efficacious and acceptable method for inadequate bowel preparation.
___
- 1. Kim WH, Cho YJ, Park JY, Min PK, Kang JK, Park IS. Factors affecting insertion time and patient discomfort during colonoscopy. Gastrointest Endosc 2000; 52: 600-605.
- 2. Rex DK, Imperiale TF, Latinovich DR, Bratcher LL. Impact of bowel preparation on efficiency and cost of colonoscopy. Am J Gastroenterol 2002; 97: 1696-1700.
- 3. Wexner SD, Beck DE, Baron TH, Fanelli RD, Hyman N, Shen B, Wasco KE. American Society of Colon and Rectal Surgeons; American Society for Gastrointestinal Endoscopy; Society of American Gastrointestinal and Endoscopic Surgeons. A consensus document on bowel preparation before colonoscopy: prepared by a task force from the American Society of Colon and Rectal Surgeons (ASCRS), the American Society for Gastrointestinal Endoscopy (ASGE), and the Society of American Gastrointestinal and Endoscopic Surgeons (SAGES). Gastrointest Endosc 2006; 63: 894-909.
- 4. Wu KL, Rayner CK, Chuah SK, Chiu KW, Lu CC, Chiu YC. Impact of low-residue diet on bowel preparation for colonoscopy. Dis Colon Rectum 2011; 54: 107-112.
- 5. Ben-Horin S, Bar-Meir S, Avidan B. The outcome of a second preparation for colonoscopy after preparation failure in the first procedure. Gastrointest Endosc 2009; 69: 626-630.
- 6. Rex DK, Petrini JL, Baron TH, Chak A, Cohen J, Deal SE, Hoffman B, Jacobson BC, Mergener K, Petersen BT et al. Quality indicators for colonoscopy. Am J Gastroenterol 2006; 101: 873-885.
- 7. Aronchick CA, Lipshutz WH, Wright SH, DuFrayne F, Bergman G. Validation of an instrument to assess colon cleansing [Abstract]. Am J Gastroenterol 1999; 94: 2667.
- 8. Rostom A, Jolicoeur E. Validation of a new scale for the assessment of bowel preparation quality. Gastrointest Endosc 2004; 59: 482-486.
- 9. Calderwood AH, Jacobson BC. Comprehensive validation of the Boston Bowel Preparation Scale. Gastrointest Endosc 2010; 72: 686-692.
- 10. Hautefeuille G, Lapuelle J, Chaussade S, Ponchon T, Molard BR, Coulom P, Laugier R, Henri F, Cadiot G. Factors related to bowel cleansing failure before colonoscopy: results of the PACOME study. United European Gastroenterol J 2014; 2: 22- 29.
- 11. Ness RM, Manam R, Hoen H, Chalasani N. Predictors of inadequate bowel preparation for colonoscopy. Am J Gastroenterol 2001; 96: 1797-1802.
- 12. Borg BB, Gupta NK, Zuckerman GR, Banerjee B, Gyawali CP. Impact of obesity on bowel preparation for colonoscopy. Clin Gastroenterol Hepatol 2009; 7: 670-675.
- 13. Hassan C, Fuccio L, Bruno M, Pagano N, Spada C, Carrara S, Giordanino C, Rondonotti E, Curcio G, Dulbecco P et al. A predictive model identifies patients most likely to have inadequate bowel preparation for colonoscopy. Clin Gastroenterol Hepatol 2012; 10: 501-506.
- 14. Chung YW, Han DS, Park KH, Kim KO, Park CH, Hahn T, Yoo KS, Park SH, Kim JH, Park CK. Patient factors predictive of inadequate bowel preparation using polyethylene glycol: a prospective study in Korea. J Clin Gastroenterol 2009; 43: 448- 452.
- 15. Hassan C, Bretthauer M, Kaminski MF, Polkowski M, Rembacken B, Saunders B, Benamouzig R, Holme O, Green S, Kuiper T et al. European Society of Gastrointestinal Endoscopy. Bowel preparation for colonoscopy: European Society of Gastrointestinal Endoscopy (ESGE) guideline. Endoscopy 2013; 45: 142-150.
- 16. Eliakim R, Yassin K, Lachter J, Chowers Y. A novel device to improve colon cleanliness during colonoscopy. Endoscopy 2012; 44: 655-659.
- 17. Mendoza J, Legido J, Rubio S, Gisbert JP. Systematic review: the adverse effects of sodium phosphate enema. Aliment Pharmacol Ther 2007; 26: 9-20.