Assessment of the maximum loadability point of a power system after third zone of distance relay corrective actions

Assessment of the maximum loadability point of a power system after third zone of distance relay corrective actions

In this paper, the operation of a system and distance relay is improved during voltage instability by using an improved strategy. After detecting the voltage instability, the third zone is blocked. However, the system is prone to voltage collapse. Shunt capacitor compensation and a load shedding scheme can be used to protect the system from voltage collapse conditions. Load shedding plans can be performed based on a reduction in the power flow in the line where the relay is located. The reason is that the minimum eigenvalue of the load flow Jacobian (reduced and unreduced Jacobians) is increased and the static voltage stability is improved. After the shunt capacitor compensation and load shedding, the relay margin becomes positive, impedance comes out from the third zone, and the relay does not need to remain blocked. The maximum loadability point (MLP) is increased by performing a control action in the system. To accomplish this strategy, the 14-bus IEEE test system is used.

___

  • [1] Kundur P. Power System Stability and Control. 1st ed. New York, NY, USA: McGraw-Hill, 1994.
  • [2] Kundur P, Paserba J, Ajjarapu V, Anderson G, Bose A, Canizares C. Definition and classification of power system stability. IEEE T Power Syst 2004; 19: 1387-1401.
  • [3] Office of Electricity Delivery & Energy Reliability. Final Report on the August 14, 2003 Blackout in the United States and Canada: Causes and Recommendations. Washington, DC, USA: Office of Electricity Delivery & Energy Reliability, 2003.
  • [4] Abidin AF, Mohamed A, Ayob A. A new method to prevent undesirable distance relay tripping during voltage collapse. Eur J Sci Res 2009; 31: 59-71.
  • [5] Shen G, Ajjarapu V. A novel algorithm incorporating system status to prevent undesirable protection operation during voltage instability. In: IEEE 2007 North American Power Symposium; 30 September–2 October 2007; Las Cruces, NM, USA. New York, NY, USA: IEEE. pp. 373-378.
  • [6] Smon I, Panto M, Gubina F. An improved voltage collapse protection algorithm based on local phasors. Elec Power Syst Res 2008; 78: 434-440.
  • [7] Verbic G, Gubina F. A novel scheme of local protection against voltage collapse based on the apparent power losses. Int J Elec Power 2004; 26: 341-347.
  • [8] Abidin FB, Mohamed A. On the use of voltage stability index to prevent undesirable distance relay operation during voltage instability. In: IEEE 2010 International Conference on Environment and Electrical Engineering; 16–19 May 2010; Czech Republic, Prague. New York, NY, USA: IEEE. pp. 384-387.
  • [9] Verbic G, Gubina F. A new concept of voltage collapse protection based on local phasors. IEEE T Pow Deliver 2004; 19: 576-581.
  • [10] Hodaei SAA, Ranjbar AM, Amraee T. Improvement of distance relay performance during voltage instability conditions. In: IEEE 2009 North American Power Symposium; 4–6 October 2009; Starkville, MS, USA. New York, NY, USA: IEEE. pp. 1-5.
  • [11] Jonsson M, Daalder JE. An adaptive scheme to prevent undesirable distance protection operation during voltage instability. IEEE T Pow Deliver 2003; 18: 1174-1180.
  • [12] Tang J. Wide area differential protection system. PhD, Florida State University, Tallahassee, FL, USA, 2006.
  • [13] Gao B, Morison GK, Kundur P. Voltage stability evaluation using modal analysis. IEEE T Power Syst 1992; 7: 1529-1542.
  • [14] Da Silva LCP, Da Costa VF, Xu W. Preliminary result on improving the modal analysis technique for voltage stability assessment. In: IEEE 2000 Power Engineering Society Summer Meeting; 16–20 July 2000; Seattle, WA, USA. New York, NY, USA: IEEE. pp. 1946-1950.
  • [15] Amjady N, Velayati MH. Evaluation of the maximum loadability point of power systems considering the effect of static load models. Energ Convers Manage 2009; 50: 3202-3210.
  • [16] Sauer PW, Lesieutre PC, Pai MA. Maximum loadability and voltage stability in power systems. Int J Elec Power 1993; 15: 145-153.
  • [17] Tare RS, Bijwe PR. A new index for voltage stability monitoring and enhancement. Int J Elec Power 1998; 20: 345-351.
  • [18] Arya LD, Sakravdia DK, Kothari DP. Corrective rescheduling for static voltage stability control. Int J Elec Power 2005; 27: 3-12.
  • [19] Ching YL, Shao HT, Yuan KW. A new approach to the assessment of steady state voltage stability margins using the P–Q–V curve. Int J Elec Power 2010; 32: 1091-1098.
  • [20] Arief A, Nappu MB, Yin X, Zhou X, Dong ZY. Under voltage load shedding design with modal analysis approach. In: IEEE 2009 International Conference on Advances in Power System Control Operation and Management; 8–11 November 2009; Hong Kong. New York, NY, USA: IEEE. pp. 1-5.
  • [21] Yunus KG, Pinares G, Tuan LA, Tjernberg LB. A combined zone-3 relay blocking and sensitivity based load shedding for voltage collapse prevention. In: IEEE 2010 Innovative Smart Grid Technologies Conference Europe; 11–13 October 2010; Gothenburg, Sweden. New York, NY, USA: IEEE. pp. 1-8.
  • [22] Lopes BIL, De Souza ACZ. An approach for under voltage load shedding. In: IEEE 2003 Power Tech Conference; 23–26 June 2003; Bologna, Italy. New York, NY, USA: IEEE. pp. 1-5.
  • [23] Arya LD, Choube SC, Shrivastava M. Technique for voltage stability assessment using newly developed line voltage stability index. Energ Convers Manage 2008; 49: 267-275.
  • [24] Boonpirom N, Paitoonwattanakij K. Static voltage stability enhancement using Facts. In: IEEE 2005 International Power Engineering Conference; 29 November–2 December 2005; Singapore. New York, NY, USA: IEEE. pp. 711-715.
  • [25] Perez MA, Messina AR, Esquivel CRF. Application of FACTS devices to improve steady state voltage stability. In: IEEE 2000 Power Engineering Society Summer Meeting; 16–20 July 2000; Seattle, WA, USA. New York, NY, USA: IEEE. pp. 1115-1120.
  • [26] Dobraca F, Pai MA, Sauer PW. Relay margin as a tool for dynamical security analysis. Int J Elec Power 1990; 12: 226-234.
  • [27] Bai H, Ajjarapu V. Transmission system vulnerability assessment based on practical identification of critical relays and contingencies. In: IEEE 2008 Power and Energy Society General Meeting; 20–24 July 2008; Pittsburgh, PA, USA. New York, NY, USA: IEEE. pp. 1-8.
  • [28] Leung KW. Computer aided setting calculation for distance zone 2 and zone 3 protection. In: IET 1991 International Conference on Advances in Power System Control Operation and Management; 5–8 November 1991; Hong Kong. Stevenage, UK: IET. pp. 152-157.
  • [29] Horowitz SH, Phadke AG. Third zone revisited. IEEE T Pow Deliver 2006; 21: 23-29.
  • [30] Moravej Z, Jazaeri M, Gholamzadeh M. Optimal coordination of distance and over current relays in series compensated system based on MAPSO. Energ Convers Manage 2012; 56: 140-151.
  • [31] Seong L. Zone 3 relay blocking scheme to prevent cascaded events. T Tianjin Univ 2008; 14: 97-105.
  • [32] Nagendra P, Dey SH, Paul S, Datta T. A novel approach for global voltage stability assessment of a power system incorporating static var compensator. Eur T Elec Power 2012; 22: 1016-1026.
  • [33] Lee SH, Liu JH, Chu CC. Modelling and locating unified power flow controllers for static voltage stability enhancements. Int T Elec Energ Syst 2012; 24: 1-17.
  • [34] Mansour MR, Geraldi EL, Costa ALF, Ramos RA. A new and fast method for preventive control selection in voltage stability analysis. IEEE T Power Syst 2013; 28: 4448-4455.
  • [35] Aman MM, Jasmon GB, Bakar AHA, Mokhlis H. Optimum network reconfiguration based on maximization of system loadability using continuation power flow theorem. Elec Power Energ Syst 2014; 54: 123-133.
  • [36] Tob´on JE, Ramirez JM, Gutierrez REC. Tracking the maximum power transfer and loadability limit from sensitivities based impedance matching. Elec Power Syst Res 2015; 119: 355-363.
  • [37] Salgado R, Takashiba J. A framework to study QV constraint exchange points in the maximum loadability analysis. Elec Power Energ Syst 2015; 64: 347-355.