An innovative peak detection algorithm for photoplethysmography signals: an adaptive segmentation method

An innovative peak detection algorithm for photoplethysmography signals: an adaptive segmentation method

The purpose of this paper is twofold. The first purpose is to detect M-peaks from raw photoplethysmography (PPG) signals with no preprocessing method applied to the signals. The second purpose is to estimate heart rate variability (HRV) by finding the peaks in the PPG signal. HRV is a measure of the fluctuation of the time interval between heartbeats and is calculated based on time series between strokes derived from electrocardiogram (ECG), arterial pressure (AP), or PPG signals, separately. PPG is a method widely used to measure blood volume of tissue on the basis of blood volume change in every heartbeat. In the estimation of the HRV signal from the PPG signal, HRV is calculated by measuring the time intervals between the peak values in the PPG signal. In the present paper, a novel peak detection algorithm was developed for PPG signals. Finding peak values correctly from PPG signals, the HRV signal can be estimated. This peak detection algorithm has been called an adaptive segmentation method (ASM). In this method, the PPG signals are first separated into segments with sample sizes and then the peak points in these signals are detected by comparing with maximum points in these segments. To evaluate the estimated pulse rate and HRV signals from PPG, Poincar´e plots and time domain features including minimum, maximum, mean, mode, standard deviation, variance, skewness, and kurtosis values were used. Our experimental results demonstrated that ASM could be even used both in the estimation of HRV signals and to detect the peaks from raw and noisy PPG signals without a pre-processing method.

___

  • [1] Bailey J, Fecteau M, Pendleton NL. Wireless pulse oximeter. Bachelor Degree Thesis, Worcester Polytechnic Institute, New York, NY, USA, 2008.
  • [2] Kyriacou PA, Powell S, Langford RM, Jones DP. Investigation of oesophageal photoplethysmographic signals and blood oxygen saturation measurements in cardiothoracic surgery patients. Physiol Meas 2002; 23: 533-545.
  • [3] Johansson A. Neural network for photoplethysmographic respiratory rate monitoring. Med Biol Eng Comput 2003; 41: 242-248.
  • [4] Binns SH, Sisson DD, Buoscio DA, Schaeffer DJ. Doppler ultrasonographic, oscillometric sphygmomanometric, and photoplethysmographic techniques for noninvasive blood-pressure measurement in anesthetized cats. J Vet Intern Med 1995; 9: 405-414.
  • [5] Allen J. Photoplethysmography and its application in clinical physiological measurement. Physiol Meas 2007; 28: 1-39.
  • [6] Usman SB, Ali MAB, Reaz MMB, Chellapan K. Second derivative of photoplethysmogram in estimating vascular aging among diabetic patients. In: International Conference for Technical Postgraduates; 14–15 December 2009; Kuala Lumpur, Malaysia: Techpos. pp. 5-7.
  • [7] Par´ak J, Havl´ık J. ECG signal processing and heart rate frequency detection methods. In: 19th Annual Conference on Technical Computing; 2011; Prague, Czech Republic: pp. 91-96.
  • [8] Akar SA, Kara S, Latifo˘glu F, Bilgi¸c V. Spectral analysis of photoplethysmographic signals: the importance of preprocessing. Biomed Signal Proces 2013; 8: 16-22.
  • [9] Teng XF, Zhang YT. Study on the peak interval variability of photoplethysmographic signals. In: IEEE EMBS Asian-Pacific Conference on Biomedical Engineering; 20–22 October 2003; Kyoto Osaka Nara, Japan: IEEE EMBS.pp. 140-141.
  • [10] McKinley PS, Shapiro PA, Bagiella E, Myers MM, De Meersman RE, Grant I, Sloan RP. Deriving heart period variability from blood pressure waveforms. J Appl Physiol 2003; 95: 1431-1438.
  • [11] Johnston W, Mendelson Y. Extracting heart rate variability from a wearable reflectance pulse oximeter. In: IEEE Proc. of 31st Annual Northeast Bioengineering; 2–3 April 2005; Hoboken, NJ, USA: IEEE. pp. 157-158.
  • [12] Sun X, Yang P, Li Y, Gao Z, Zhang YT. Robust heart beat detection from photoplethysmography interlaced with motion artifacts based on empirical mode decomposition. In: IEEE-EMBS International Conference on Biomedical and Health Informatics (BHI); 5–7 Jan. 2012; Shenzhen, Hong Kong: IEEE. pp. 775-778.
  • [13] Liu SH, Chang KM, Fu TH. Heart rate extraction from photoplethysmogram on fuzzy logic discriminator. Eng Appl Artif Intel 2010; 23: 968-977.
  • [14] Aboy, M, McNames J, Tran Thong, Tsunami D, Ellenby MS, Goldstein B. An automatic beat detection algorithm for pressure signals. IEEE T Bio-Med Eng 2005; 52: 1662-1670.
  • [15] Shin HS, Lee C, Lee M. Adaptive threshold method for the peak detection of photoplethysmographic waveform. Comput Biol Med 2009; 39: 1145-1152.
  • [16] Goldberger AL, Amaral LAN, Glass L, Hausdorff JM, Ivanov PCh, Mark RG, Mietus JE, Moody GB, Peng CK, Stanley HE. PhysioBank, PhysioToolkit, and PhysioNet: components of a new research resource for complex physiologic signals. Circulation 2000; 101: 215-220.
  • [17] Bolanos M, Nazeran H, Haltiwanger E. Comparison of heart rate variability signal features derived from electrocardiography and photoplethysmography in healthy individuals. In: Proceedings of the 28th IEEE EMBS Annual International Conference; Aug 30–Sept 3 2006; New York, NY, USA: IEEE. pp. 4289- 4294.
  • [18] Brennam M, Palaniswami M, Kamen P. Do existing measures of poincar´e plot geometry reflect nonlinear features of heart rate variability? IEEE T Bio-Med Eng 2001; 48: 1342-1347.
  • [19] Ate¸s G, Polat K, Measuring of oxygen saturation using pulse oximeter based on fuzzy logic. In: IEEE MeMeA International Symposium on Medical Measurements and Applications; 18–19 May 2012; 2012; Budapest, Hungary: IEEE. pp. 51-56.
Turkish Journal of Electrical Engineering and Computer Sciences-Cover
  • ISSN: 1300-0632
  • Yayın Aralığı: 6
  • Yayıncı: TÜBİTAK
Sayıdaki Diğer Makaleler

Computation of the scattered fields from an arbitrary discontinuity on a perfectly conducting ground plane by a decomposition method

Ahmet KIZILAY, Uğur SAYNAK

Sizing design and implementation of a flywheel energy storage system for space applications

Kutlay AYDIN, Mehmet Timur AYDEMİR

Design and implementation of a man-overboard emergency discovery system based on wireless sensor networks

Cüneyt BAYILMIŞ, Hüseyin EKİZ, Abdullah SEVİN, İsmail ERTŞRK, Ahmet KARACA

Comparative performance evaluation of blast furnace flame temperature prediction using artificial intelligence and statistical methods

Etem KÖKLÜKAYA, Yasin TUNÇKAYA

Quantitative information extraction from gas sensor data using principal component regression

Ahmet ÖZMEN, Zafer Ziya ÖZTÜRK, Cihat TAŞALTIN, İlke GÜRÖL, Deniz DURAL, Bekir MUMYAKMAZ, Mehmet Ali EBEOĞLU

Fast and accurate semiautomatic haptic segmentation of brain tumor in 3D MRI images

Erhan İlhan KONUKSEVEN, Adnan ALTUN, Masoud LATIFI NAVID, Mustafa DOĞAN, Murat BİLEN

Comparative study of drive systems using vector-controlled PMSM fed by a matrix converter and a conventional frequency converter

Pawel SZCZESNIAK, Konrad URBANSKI, Zbigniew FEDYCZAK, Krzysztof ZAWIRSKI

A parametric study on privatization revenues of the electricity distribution companies in Turkey

Selim AY, Ercan İZGİ

Improved control of a photovoltaic pumping system by DTC-SVM to optimize the water flow

Moulay Idriss CHERGUI

Online monitoring and accident diagnosis aid system for the Nur Nuclear Research Reactor

Amina Nasrine ALLALOU, Mohamed TADJINE, Mohamed Seghir BOUCHERIT