Farklı dış duvar yapıları için optimum ısı yalıtım kalınlığı tespitinin ekonomik analizi

In the countries which supply big amount of their energy needs by import like Turkey using the energy economically is important. Thermal insulation technologies in buildings are the main method for using energy economically. But choosing the thickness of the insulation material redundant causes high insulation costs. For this reason, an optimum point which provides the highest price in insulation applications is the subject. In this study, different building materials (horizontal perforated brick and gas concrete), and isolated forms of insulation (exterior insulation and insulation sandwich) was a model of a building exterior wall. The study determined that the wall and the heat loss through the life-cost analysis, according to the present calculations (LCCA), the optimum thickness of insulation, energy savings and payback periods were determined.

Economical analysis of determination thermal insulation thickness for different external walls

-

___

  • Dombaycı, Ö.A., “Degree-days maps of Turkey for various base temperatures”, Energy, 34, 1807-1812, 2009.
  • Deniz, E., Gürel, A. E., Daşdemir, A., Çamur, D., “Fuel Consumption and Influences Extarnal Wall Optimum Insulation Thickness to Owning Cost of Energy, Technology, ss: 283-290, 12(4), 2009.
  • Hasan, A., “Optimizing insulation thickness for buildings using life cycle cost”. Applied Energy, 63, 115-124, 1999. Dombaycı,
  • “Optimization of insulation thickness for external walls using different energy-sources”. Applied Energy, 83, 921–928, 2006.
  • Bolattürk, A., “Determination of optimum thickness for building walls with respect to various fuels and climate zones in Turkey”, Applied thermal engineering, 26, 1301-1309, 2006.
  • Uçar, A., Balo, F., Effect of fuel type on the optimum thickness of selected insulation materials for the four different climatic regions of Turkey, Applied Energy, 86, 730-736, 2009.
  • Çomaklı, K., Yüksel, B., Environmental impact of thermal insulation thickness in buildings. Applied Thermal Engineering, 24(2), 933–940, 2004.
  • Yu, J., Yang, C., Tian, L., Liao, D., A study on optimum insulation thicknesses of external walls in hot summer and cold winter zone of China, Applied Energy, 86, 2520-2529, 2009.
  • Gölcü, M., Dombaycı, A,Ö., Abalı, S.,”Denizli İçin Optimum Yalıtım Kalınlığının Enerji Tasarrufuna Etkisi ve Sonuçları”, Gazi Üniversitesi Mühendislik Mimarlık Fakültesi Dergisi, Cilt 21, No 4, s. 639- 644, 2006. M, Pancar
  • Y. [5] [6] [7] [8] [9]