Exergoeconomic and exergoenvironmental analysis of the evacuated tube heat pipe; a experimental study

In this paper, the effect of the different parameters such as solar radiation, and ambient temperature on thermodynamic performance of a Water-in-glass evacuated tube heat pipe (ETHP) is studied, including energy, exergy, environmental, economic analysis, and sustainability index. The ETHP system is evaluated under the 4E criteria; energy, exergy, economic, and environment. The energy, exergy, environmental, enviroeconomic, exergoenvironmental, exergoenviroeconomical analysis and sustainability index of the ETHP system is calculated. There are 4 collectors each collector 57 pipes as a total of 108 pieces pipes, a hot water tank, a heat exchanger, and a pump in the system. The water is used as a working fluid due to economic, and common use in the system. In the result of this experimental study, we calculated energy and exergy efficiencies of the EHTP system as %60.74 and %40.72, respectively. In addition, the environmental, exergoenviromental, enviroeconomic, and exergoenviroeconomic values of the EHTP system are found 5958.01 kgCO2/day, 5564.72 kgCO2/day, 0.7448 $/day and 0.6958 $/day, respectively. Also, the sustainability index of the system is found as 1.687.

___

  • [1] B. Erten, Z. Utlu, “Photovoltaic system configurations: an occupational health and safety assessment,” Greenhouse Gases Science and Technology, 10 (4), 809-828. https://doi.org/10.1002/ghg.2009
  • [2] B. Du, P.D. Lund, J. Wang, “Combining CFD and artificial neural network techniques to predict the thermal performance of all-glass straight evacuated tube solar collector,” Energy, 220, 119713, https://doi.org/10.1016/j.energy.2020.119713 [3] B. Pourkafi, B.M. Ziapour, A.R. Miroliaei, “Numerical study of the transparent cover effects with miscellaneous shapes on the parabolic trough solar collector performance,” International Journal of Thermodynamics, 23 (1), 1-23, https://doi.org/10.5541/ijot.601417
  • [4] A. Maraj, A. Londo, A. Gebremedhin, C. Firat, “Energy performance analysis of a forced circulation solar water heating system equipped with a heat pipe evacuated tube collector under the Mediterranean climate conditions,” Renewable Energy, 140, 874-883, https://doi.org/10.1016/j.renene.2019.03.109
  • [5] Chr. Lamnatou, E. Papanicolaou, V. Belessiotis, N. Kyriakis, “Experimental investigation and thermodynamic performance analysis of a solar dryer using an evacuated-tube air collector,” Applied Energy, 94, 232-243, https://doi.org/10.1016/j.apenergy.2012.01.025
  • [6] M. Eltaweel, A.A. Abdel-Rehim, A.A.A. Attia, “Energetic and exergetic analysis of a heat pipe evacuated tube solar collector using MWCNT/water nanofluid,” Case Studies in Thermal Engineering, 22, 100743, https://doi.org/10.1016/j.csite.2020.100743
  • [7] Chr. Lamnatou, E. Papanicolaou, V. Belessiotis, N. Kyriakis, “Experimental investigation and thermodynamic performance analysis of a solar dryer using an evacuated-tube air collector,” Applied Energy, 94, 232-243, https://doi.org/10.1016/j.apenergy.2012.01.025
  • [8] N. Modi, B. Pandya, “Integration of Evacuated Solar Collectors with an Adsorptive Ice Maker for Hot Climate Region,” Energy and Built Envrionment, in press, https://doi.org/10.1016/j.enbenv.2021.01.001
  • [9] G. Saxena, M.K. Gaur, “ Energy, exergy and economic analysis of evacuated tube solar water heating system integrated with heat exchanger,” Materials today: Proceedings, 28 (4), 2452-2462, https://doi.org/10.1016/j.matpr.2020.04.793
  • [10] A.V. Kumar, T.V. Arjunan, D. Seenivasan, R.Venkatramanan, S. Vijayan, “ Thermal performance of an evacuated tube solar collector with inserted baffles for air heating applications,” Solar Energy, 215, 131-143, https://doi.org/10.1016/j.solener.2020.12.037
  • [11] H. Olfian, S.S.M. Ajarostaghi, M. Farhadi, A. Ramiar, “Melting and solidification processes of phase change material in evacuated tube solar collector with U-shaped spirally corrugated tube,” Applied Thermal Engineering, 182, 116149, https://doi.org/10.1016/j.applthermaleng.2020.116149
  • [12] A. Ozsoy, V. Corumlu, “Thermal performance of a thermosyphon heat pipe evacuated tube solar collector using silver-water nanofluid for commercial applications,” Renewable Energy, 122, 26-34, https://doi.org/10.1016/j.renene.2018.01.031
  • [13] V. Corumlu, A. Ozsoy, M. Ozturk, “Thermodynamic studies of a novel heat pipe evacuated tube solar collectors based integrated process for hydrogen production,” International Journal of Hydrogen Energy, 43 (2), 1060-1070, https://doi.org/10.1016/j.ijhydene.2017.10.107
  • [14] O. Kizilkan, S. Khanmohammadi, H. Yamaguchi, “Two-objective optimization of a transcritical carbon dioxide based Rankine cycle integrated with evacuated tube solar collector for power and heat generation”, Applied Thermal Engineering, 182, 116079, https://doi.org/10.1016/j.applthermaleng.2020.116079
  • [15] M. Ozturk, I. Dincer, “Thermodynamic analysis of a solar-based multi-generation system with hydrogen production,” Applied Thermal Engineering, 51 (1-2), 1235-1244, https://doi.org/10.1016/j.applthermaleng.2012.11.042
  • [16] A.Y. Faraji, A. Date, R. Singh, A. Akbarzadeh, “Base-load Thermoelectric Power Generation Using Evacuated Tube Solar Collector and Water Storage Tank,” Energy Procedia, 57, 2112-2120, https://doi.org/10.1016/j.egypro.2014.10.178
  • [17] R. K. Kumar, N.V.V.K. Chaitanya, N.S. Kumar, “Solar thermal energy technologies and its applications for process heating and power generation – A review,” Journal of Cleaner Production, 282, 125296, https://doi.org/10.1016/j.jclepro.2020.125296
  • [18] D.S. Ayou, G. Zaragoza, A. Coronas, “Small-scale renewable polygeneration system for off-grid applications: Desalination, power generation and space cooling,” Applied Thermal Engineering, 182, 116112, https://doi.org/10.1016/j.applthermaleng.2020.116112
  • [19] J.Z. Alvi, Y. Feng, Q. Wang, M. Imran, G. Pei, “Effect of working fluids on the performance of phase change material storage based direct vapor generation solar organic Rankine cycle system,” Energy Reports, 7, 348-361, https://doi.org/10.1016/j.egyr.2020.12.040
  • [20] O. Kizilkan, H. Yamaguchi, “Feasibility research on the novel experimental solar-assisted CO2 based Rankine cycle integrated with absorption refrigeration,” Energy Conversion and Management, 205, 112390, https://doi.org/10.1016/j.enconman.2019.112390
  • [21] O. Kizilkan, S. Khanmohammadi, M. Saadat-Targhi, “Solar based CO2 power cycle employing thermoelectric generator and absorption refrigeration: Thermodynamic assessment and multi-objective optimization,” Energy Conversion and Management, 200, 112072, https://doi.org/10.1016/j.enconman.2019.112072
  • [22] H. Caliskan, “Energy, exergy, environmental, enviroeconomic, exergoenvironmental (EXEN) and exergoenviroeconomic (EXENEC) analyses of solar collectors,” Renewable and Sustainable Energy Reviews, 69, 488-492, https://doi.org/10.1016/j.rser.2016.11.203
  • [23] O.A. López-Núñez, J.A. Alfaro-Ayala, J.J. Ramírez-Minguela, J.M. Belman-Flores, O.A. Jaramillo, “Optimization of a Linear Fresnel Reflector Applying Computational Fluid Dynamics, Entropy Generation Rate and Evolutionary Programming,” Renewable Energy, 152, 698-712, https://doi.org/10.1016/j.renene.2020.01.105
  • [24] D. Aydin, Z. Utlu, O. Kincay, “Thermal performance analysis of a solar energy sourced latent heat storage,” Renewable and Sustainable Energy Reviews, 50, 1213-1225, https://doi.org/10.1016/j.rser.2015.04.195
  • [25] S. Abo-Elfadl, H. Hassan, M.F. El-Dosoky, “Energy and exergy assessment of integrating reflectors on thermal energy storage of evacuated tube solar collector-heat pipe system,” Solar Energy, 209, 470-484, https://doi.org/10.1016/j.solener.2020.09.009 [26] H. Caliskan, I. Dincer, A. Hepbasli, “Exergoeconomic and environmental impact analyses of a renewable energy based hydrogen production system,” International Journal of Hydrogen Energy, 38(14), 6104-6111, https://doi.org/10.1016/j.ijhydene.2013.01.069
  • [27] A. Fudholi, M. Zohri, N.S.B. Rukman, N.S. Nazri, M. Mustapha, A.H. Yen, M. Mohammad, K. Sopian, “Exergy and sustainability index of photovoltaic thermal (PVT) air collector: A theoretical and experimental study,” Renewable and Sustainable Energy Reviews, 100, 44-51, https://doi.org/10.1016/j.rser.2018.10.019
  • [28] O.A. López-Núñez, J.A. Alfaro-Ayala, O.A. Jaramillo, J.J. Ramírez-Minguela, J.C. Castro, C.E. Damian-Ascencio, S. Cano-Andrade, “A numerical analysis of the energy and entropy generation rate in a Linear Fresnel Reflector using computational fluid dynamics,” Renewable Energy, 146, 1083-1100, https://doi.org/10.1016/j.renene.2019.06.144
  • [29] M. Faizal, R. Saidur, S. Mekhilef, M.A. Alim, “Energy, economic and environmental analysis of metal oxides nanofluid for flat-plate solar collector,” Energy Converison and Management, 76, 162-168, https://doi.org/10.1016/j.enconman.2013.07.038
  • [30] M.S. Yousef, H. Hassan, H. Sekiguchi, “Energy, exergy, economic and enviroeconomic (4E) analyses of solar distillation system using different absorbing materials,” Applied Thermal Engineering, 150, 30-41, https://doi.org/10.1016/j.applthermaleng.2019.01.005
  • [31] U. Akbulut, Z. Utlu, O. Kincay, “Exergy, exergoenvironmental and exergoeconomic evaluation of a heat pump-integrated wall heating system,” Energy, 107, 502-522, https://doi.org/10.1016/j.energy.2016.04.050
  • [32] K.G. Mofrad, S. Zandi, G. Salehi, M.H.K. Manesh, “Comparative 4E and advanced exergy analyses and multi-objective optimization of refrigeration cycles with a heat recovery system,” International Journal of Thermodynamics, 23(4), 197-214, https://doi.org/10.5541/ijot.749471