Comparison of Microwave and Conventional Driven Adsorption Heat Pump Cycle Duration

The present experimental study includes comparison of microwave regenerated and conventional heated adsorbent bed of adsorption heat pump. The novel adsorption heat pump driving with microwave heating system was designed and manufactured. Microwave oven was constructed for providing homogeneous temperature distribution in the adsorbent bed. Temperature and pressure variations in the adsorption heat pump for both microwave and conventional regenerated cycles were measured and investigated. Duration of isobaric desorption process with microwave heating was achieved 98.2% shorter than that of conventional heating system.

___

  • H. Demir, M. Mobedi, S. Ulku, “A review on adsorption heat pump: Problems and solutions”, Renew. Sustain. Energy Rev, vol. 12, pp. 2381–2403, 2008.
  • K.E. Haque, “Microwave energy for mineral treatment processes: a brief review”, Int. J. Miner. Process. vol. 57, pp. 1-24, 1999.
  • M. Kumja, C.K. Ng, C. Yap, H. Yanaghi, S. Koyama, B.B. Saha, A.Chakraborty, “Modeling of a novel desorption cycle by dielectric heating”, Mod. Physic. Lett. B, vol. 23, pp. 425-428, 2009.
  • H. Demir, “The effect of microwave regenerated adsorbent bed on the performance of an adsorption heat pump”, Appl. Therm. Eng. Vol. 50, pp. 134-142, 2013.
  • G. Alefeld, P. Maier-Laxhuber, M. Rothmeyer, “Zeolite heat pump and zeolite heat transformer for load management”, In: Proc. of solid sorption refrigeration symposium, Paris, pp. 855-860, November 1992.