Optimization of Air Distribution in A Non-Ducted Concealed Type Fancoil Unit Heat Exchanger

Optimization of Air Distribution in A Non-Ducted Concealed Type Fancoil Unit Heat Exchanger

In this study, increasing efficiency of a heat exchanger as a sub part of concealed ceiling type fan coil unit is aimed. Accordingly, by determining rotational speed of fans based on actual design; generated air distribution in dry condition on heat exchanger is investigated via computational fluid dynamics software. Significant low air distribution is detected in lower and higher sides of the heat exchanger. In order to create solution to this issue and to increase efficiency, by designed air distributor, homogenized air distribution is targeted. As a conclusion, differentiation of air velocities and air distribution is investigated based on various angles. By means of the distributor with an optimum design angle, air distribution is improved and more homogenous air distribution is achieved.

___

  • [1] N. Kim, D. Kim, Y. Choi, H. Byun, J. Hwang, "Effect of Inclination Angle on the Air-side Performance of Aluminum Parallel Flow Heat Exchangers Under Wet Conditions", International Refrigeration and Air Conditioning Conference, 2008.
  • [2] P. Karthik, V. Kumaresan, R. Velraj, "Experimental and Parametric Studies of A Louvred Fin and Flat Tube Compact Heat Exchanger Using Computational Fluid Dynamics", Alexandria Engineering Journal, vol. 54, no. 4, pp. 905–915, 2015, https://doi.org/10.1016/j.aej.2015.08.003
  • [3] A. Vaisi, M. Esmaeilpour, H. Taherian, "Experimental Investigation of Geometry Effects on the Performance of A Compact Louvred Heat Exchanger", Applied Thermal Engineering, vol. 31, no. 16, pp. 3337–3346, 2011, https://doi.org/10.1016/j.applthermaleng.2011.06.014
  • [4] W. J. Lee, J. H. Jeong, "Heat Transfer Performance Variations of Condensers Due to Non-Uniform Air Velocity Distributions", International Journal of Refrigeration, vol. 69, p. 85–95, 2016,https://doi.org/10.1016/j.ijrefrig.2016.05.009
  • [5] A. Firouzar, "Bir Fan-Coil Ünitesinin Performansının Deneysel ve Sayısal Olarak Analizi", Gazi University, Science Institue, Mechanical Engineering Department, MSc Thesis, 2014.
  • [6] Eurovent RS 6/C/002-2017, "Rating Standard for The Certification of Non-Ducted Fan-coil Ünits", Paris: Eurovent Certita Certification, p. 4–7.
International Journal of Computational and Experimental Science and Engineering-Cover
  • Yayın Aralığı: 4
  • Başlangıç: 2015
  • Yayıncı: Prof.Dr. İskender Akkurt
Sayıdaki Diğer Makaleler

Vibration Behavior of Composite Materials Produced by Waste Metal Recycling

Aydın GÜNEŞ, Erdi GÜLBAHÇE, Emin SALUR, Abdullah ASLAN, Ömer Sinan ŞAHİN

Research and application of DCA microspheres as deep profile control agent in low permeability reservoir

Xuedong SHİ, Xiang’an YUE, Mingda DONG, Changchun YANG

Optimization of Air Distribution in A Non-Ducted Concealed Type Fancoil Unit Heat Exchanger

Murat OZSOY, Canberk YUCEL, Onur VARLICA, Serhan KILIÇ, Kagan KAPLAN

The Effect of Exhaust Temperature on Urea-Water Decomposition in Marine SCR Systems

Kubilay BAYRAMOĞLU, Güner ÖZMEN, A. Güldem CERİT

Comparing the Effect of Process Fluid for Wet Ground Heat Exchanger

Ufuk DURMAZ, Orhan YALÇINKAYA

Experimental Investigation of Surface Roughness of Cutting Parameters in T6 Aluminum Alloy Milling Process

Neslihan ÖZSOY

Determination of the Radiation Dose Level in Different Slice Computerized Tomography

Osman GÜNAY, Özcan GÜNDOĞDU, Mustafa DEMİR, Mohammad ABUQBEİTAH, Doğan YAŞAR, Serpil AKÖZCAN, Enis KAPDAN, Onur YARAR

Investigation From Different Calculation Solutions In Vertebra Plans And The Reliability Of Different Dose Rate Dose

Yonca Yahşi ÇELEN, Hazım Orhan KIZILKAYA

Investigation of The Effect of Intermediate Dose Calculation Module on Dose Dıstrıbutıon in Lung Cancer Radiotherapy Patients

Yonca YAHŞİ ÇELEN, Hazım Orhan KIZILKAYA

Recycling and Characterization of Metallic Chips Using Powder Metallurgy

Handan DEMİREL, Aydın GÜNEŞ, Ömer Sinan ŞAHİN