An experimental test set-up with the ANSI / AMCA 210-16 standard for performance analysis of axial fans

An experimental test set-up with the ANSI / AMCA 210-16 standard for performance analysis of axial fans

The fact that fans are used in a large variety and wide areas today requires them to have a certain performance and quality. The test set-up to be used to determine the performance values of the fans should also be prepared and verified in accordance with standards such as ISO, ANSI / AMCA. In this study, a test set-up was designed and established in accordance with the ANSI / AMCA 210-16 standard. In order to ensure the accuracy of this test set-up, the static pressure values for different flow rates of the AXI500-5-25 model axial fan produced in a fan manufacturer company in Konya were measured, and data were obtained. The static pressure-flow rate performance curve obtained from the tests was compared with the manufacturer's catalog data. As the most important result in comparison, it was seen that the experimental and the catalog data were quite compatible. The highest difference between experimental and catalog data was obtained at the points where the flow rate is minimum and maximum. However, this difference was determined to be around 5%. With the results obtained in the study, it was determined that the accuracy of the experimental set-up designed and set up according to ANSI/AMCA 210-16 standard was ensured and it was suitable to be used for testing.

___

  • Eck,B., Fans, Design and Operation of Centrifugal, Axial Flow And Cross Flow Fans, First Edition, Biddles Ltd., Great Britain,1972.
  • Canbazoğlu,S., Fan Mühendisliği-1, First Edition, Aironn Fan Mühendisliği Teknik Yayın, Turkey, 2020.
  • Çakmanus, İ., Endüstriyel Fanlar Tasarım, İmalat ve Enerji Verimliliği, First Edition, TTMD Teknik Yayın No:23, Turkey,2009.
  • Elliot,N., and Nadel,S.,Realizing Energy Efficiency Opportunities in Industrial Fan and Pump Systems, Report Number A304,USA, 2003.
  • Waide,P., and Brunner,C., Energy-Efficiency Policy Opportunities for Electric Motor-Driven Systems, Working Paper, International Energy Agency, France,2011.
  • TEDAŞ, 2019 Yili Türkiye Elektrik Dağitimi Sektör Raporu, Turkey,2020.
  • Bleier,F., Fan Handbook Selection, Application and Design, First Edition, McGraw Hill,USA,1997.
  • Zhu, X., Lin, W., and Du, Z., 2004.Experimental and Numerical Investigation of the Flow Field in the Tip Region of an Axial Ventilation Fan. ASME. J. Fluids Engineering,127(2),299–307.
  • Li, Y., Liu, J., Ouyang, H., and Du, Z. 2008. Internal flow Mechanism and Experimental Research of Low-Pressure Axial fan with Forward-Skewed Blades. Journal of Hydrodynamics, Ser. B,20(3), 299–305.
  • Cho, L., Cha, B., and Cho, J. 2009. Experimental Study on the Three-Dimensional Unsteady Flow Characteristics of the Counter-Rotating Axial Flow Fan. Journal of Fluid Science and Technology, 4, 200-209.
  • Munisamy,K., Govindasamy,R., and Thangaraju,S., 2012. Experimental and Numerical Investigation onto 1250mm Axial Fan. Applied Mechanics and Materials, 225(x), 91-96. doi:10.4028/www.scientific.net/AMM.225.91
  • Zhang, S., 2015. Experimental study on performance of contra-rotating axial flow fan. Int J Coal Sci Technol 2, 232–236.
  • Castegnaro, S., Masi,M., and Lazzaretto,A., 2018. Design and Testing of an ISO 5801 Inlet Chamber Test Rig and Related Issues with the Standard. FAN 2018 - International Conference on Fan Noise, Aerodynamics, Applications & Systems, April 2018, Darmstadt, Germany
  • ANSI/AMCA Standard 210-16, ASHRAE Standard 51-16, Laboratory Methods of Testing Fans for Certified Aerodynamic Performance Rating, USA,2016
  • http://www.kayites.com/assets/upload/folder/publish/normal/kayites_20213317143302.pdf , (08.03.2021)