SECTIONAL MANDIBULAR COMPLETE DENTURE FOR A TOTAL MAXILLECTOMY PATIENT WITH TRISMUS: A CLINICAL REPORT

This report presents the case of a 60-year-old male patient with trismus induced by radiotherapy and fabrication of a sectional mandibular complete denture to allow the insertion of the denture into the mouth. A mandibular sectional denture was designed in two pieces with a locking mechanism by using mini anchor and ball abutment housing with cap. Patients who have undergone maxillectomy often have constricted mouth openings, as a result of surgical intervention and radiotherapy, and complain of an inability to insert or remove dentures. A new approach is vital for sectional dentures because existing sectional denture fabrication techniques cannot meet the ongoing needs of trismus patients. The mini anchor system with ball abutment housing has better mechanical retention in acrylic resin and can provide favorable stabilization during masticatory function; thus, additional framework is not required for assisting in stabilization and retention.

___

  • Beekhuis GJ, Harrington EB. Trismus. Etiology and management of inability to open the mouth. Laryngoscope 1965;75:1234-1258.
  • Rapidis AD, Dijkstra PU, Roodenburg JL, Rodrigo JP, Rinaldo A, Strojan P, Takes RP, Ferlito A. Trismus in patients with head and neck cancer: Etiopathogenesis, diagnosis and management. Clin Otolaryngol 2015;40(6):516-526.
  • Okunieff P, Augustine E, Hicks JE, Cornelison TL, Altemus RM, Naydich BG, Ding I, Huser AK, Abraham EH, Smith JJ, Coleman N, Gerber LH. Pentoxifylline in the treatment of radiation-induced fibrosis. J Clin Oncol 2004;22(11):2207-2213.
  • Wang CJ, Huang EY, Hsu HC, Chen HC, Fang FM, Hsiung CY. The degree and time-course assessment of radiation-induced trismus occurring after radiotherapy for nasopharyngeal cancer. Laryngoscope 2005;115(8):1458-1460.
  • Dijkstra PU, Huisman PM, Roodenburg JL. Criteria for trismus in head and neck oncology. Int J Oral Maxillofac Surg 2006;35(4):337-342.
  • Matsumura H, Kawasaki K. Magnetically connected removable sectional denture for a maxillary defect with severe undercut: A clinical report. J Prosthet Dent 2000;84(1):22-26.
  • Cura C, Cotert HS, User A. Fabrication of a sectional impression tray and sectional complete denture for a patient with microstomia and trismus: A clinical report. J Prosthet Dent 2003;89(6):540-543.
  • Gozde Turk A, Ulusoy M. A collapsible partial denture for a patient with limited mouth opening induced by scleroderma: A clinical report. J Prosthodont 2015;24(4):334-338.
  • Sinavarat P, Anunmana C. Sectional collapsible complete removable dental prosthesis for a patient with microstomia. J Prosthet Dent 2015;114(5):627-632.
  • Yenisey M, Kulunk T, Kurt S, Ural C. A prosthodontic management alternative for scleroderma patients. J Oral Rehabil 2005;32(9):696-700.
  • Al-Hadi LA, Abbas H. Treatment of an edentulous patient with surgically induced microstomia: A clinical report. J Prosthet Dent 2002;87(4):423-426.
  • Ohkubo C, Watanabe I, Tanaka Y, Hosoi T. Application of cast iron-platinum keeper to a collapsible denture for a patient with constricted oral opening: A clinical report. J Prosthet Dent 2003;90(1):6-9.
  • Suzuki Y, Abe M, Hosoi T, Kurtz KS. Sectional collapsed denture for a partially edentulous patient with microstomia: A clinical report. J Prosthet Dent 2000;84(3):256-259.
  • Winkler S, Wongthai P, Wazney JT. An improved split-denture technique. J Prosthet Dent 1984;51(2):276-279.
  • Geckili O, Cilingir A, Bilgin T. Impression procedures and construction of a sectional denture for a patient with microstomia: A clinical report. J Prosthet Dent 2006;96(6):387-390.
  • Benetti R, Zupi A, Toffanin A. Prosthetic rehabilitation for a patient with microstomia: A clinical report. J Prosthet Dent 2004;92(4):322-327.
  • Hajimahmoudi M, Mostafavi AS. A simple and effective method for prosthetic rehabilitation in scleroderma patients: A clinical report. Int J Prosthodont 2014;27(2):169-173.
  • Colvenkar SS. Sectional impression tray and sectional denture for a microstomia patient. J Prosthodont 2010;19(2):161-165.
  • Kanazawa T, Yoshida H, Furuya Y, Shimodaira K. Sectional prosthesis with hollow obturator portion made of thin silicone layer over resin frame. J Oral Rehabil 2000;27(9):760-764.
  • Wang RR. Sectional prosthesis for total maxillectomy patients: A clinical report. J Prosthet Dent 1997;78(3):241-244.
  • Watanabe I, Tanaka Y, Ohkubo C, Miller AW. Application of cast magnetic attachments to sectional complete dentures for a patient with microstomia: A clinical report. J Prosthet Dent 2002;88(6):573-577.