Comparison of newly formed microcracks after instrumentation using Protaper Next, Reciproc and Self-Adjusting File systems
Purpose
___
- Kansal R, Rajput A, Talwar S, Roongta R, Verma M. Assessment of
dentinal damage during canal preparation using reciprocating
and rotary files. J Endod 2014;40(9):1443-6. [CrossRef ]
- Wilcox LR, Roskelley C, Sutton T. The relationship of root canal
enlargement to finger-spreader induced vertical root fracture. J
Endod 1997;23(8):533-4. [CrossRef ]
- Yoldas O, Yilmaz S, Atakan G, Kuden C, Kasan Z. Dentinal
microcrack formation during root canal preparations by
different NiTi rotary instruments and the self-adjusting file. J
Endod 2012;38(2):232-5. [CrossRef ]
- Burklein S, Tsotsis P, Schafer E. Incidence of dentinal defects
after root canal preparation: reciprocating versus rotary
instrumentation. J Endod 2013;39(4):501-4. [CrossRef ]
- Ruddle CJ, Machtou P, West JD. The shaping movement: fifthgeneration
technology. Dent Today 2013;32(4):94, 96-9.
- Metzger Z, Teperovich E, Zary R, Cohen R, Hof R. The selfadjusting
file (SAF). Part 1: respecting the root canal anatomy-
-a new concept of endodontic files and its implementation. J
Endod 2010;36(4):679-90. [CrossRef ]
- Metzger Z, Teperovich E, Cohen R, Zary R, Paque F, Hulsmann
M. The self-adjusting file (SAF). Part 3: removal of debris and
smear layer-A scanning electron microscope study. J Endod
2010;36(4):697-02. [CrossRef ]
- De-Deus G, Silva EJ, Marins J, et al. Lack of causal relationship
between dentinal microcracks and root canal preparation with
reciprocation systems. J Endod 2014;40(9):1447-50. [CrossRef ]
- De-Deus G, Belladonna FG, Souza EM, et al. Micro-computed
Tomographic Assessment on the Effect of ProTaper Next and
Twisted File Adaptive Systems on Dentinal Cracks. J Endod
2015;41(7):1116-9. [CrossRef ]
- Ceyhanli KT, Erdilek N, Tatar I, Celik D. Comparison of ProTaper,
RaCe and Safesider instruments in the induction of dentinal
microcracks: a micro-CT study. Int Endod J 2016;49(7):684-9.
[CrossRef ]
- Liu R, Hou BX, Wesselink PR, Wu MK, Shemesh H. The incidence of
root microcracks caused by 3 different single-file systems versus
the ProTaper system. J Endod 2013;39(8):1054-6. [CrossRef ]
- Capar ID, Arslan H, Akcay M, Uysal B. Effects of ProTaper Universal,
ProTaper Next, and HyFlex instruments on crack formation in
dentin. J Endod 2014;40(9):1482-4. [CrossRef ]
- Karatas E, Gunduz HA, Kirici DO, Arslan H, Topcu MC, Yeter KY.
Dentinal crack formation during root canal preparations by the
twisted file adaptive, ProTaper Next, ProTaper Universal, and
WaveOne instruments. J Endod 2015;41(2):261-4. [CrossRef ]
- Ashwinkumar V, Krithikadatta J, Surendran S, Velmurugan N.
Effect of reciprocating file motion on microcrack formation
in root canals: an SEM study. Int Endod J 2014;47(7):622-7.
[CrossRef ]
- Ustun Y, Aslan T, Sagsen B, Kesim B. The effects of different nickeltitanium
instruments on dentinal microcrack formations during
root canal preparation. Eur J Dent 2015;9(1):41-6. [CrossRef ]
- Hin ES, Wu MK, Wesselink PR, Shemesh H. Effects of selfadjusting
file, Mtwo, and ProTaper on the root canal wall. J
Endod 2013;39(2):262-4. [CrossRef ]