PERFORMANCE ANALYSIS OF DOUBLE REHEAT TURBINE IN MULTI -AREA AGC SYSTEM USING CONVENTIONAL AND ANT COLONY OPTIMIZATION TECHNIQUE

PERFORMANCE ANALYSIS OF DOUBLE REHEAT TURBINE IN MULTI -AREA AGC SYSTEM USING CONVENTIONAL AND ANT COLONY OPTIMIZATION TECHNIQUE

The responsibility of power system is to ensure that adequate power generation with good quality and more economic power delivery to all consumers. Hence, proper control strategy is required to maintain a continuous power balance between power generation and surplus. So it is necessary to implement Automatic Generation control for more efficient control performance. In this paper , three area reheat thermal power is considered for the investigation and each generating unit equipped with either Single Reheat Turbine (SRT) or Double Reheat Turbine (DRH) with Proportional-Integral-Derivative(PID) controller. Optimal controller gain values are obtained using both conventional and Artificial Intelligence (AI) optimization technique. Finally, performances of AI-PID controller are compared with conventional optimized PID controller. Simulation result shows that contribution of AGC with AI PID controller more superior to conventional controller.

___

  • S.Banerjee, J.K.Chatterjee, S.C.Tripathy, “Application of
  • magnetic energy storage unit as load-frequency stabilizer,” IEEE transactions on energy conversion, Vol. 5, pp. 46-51, 1990.
  • S.C.Tripathy,R.Balasubramanian, P.S.Chandramohanan Nair
  • “Small rating capacitive energy storage for dynamic performance improvement of automatic generation control,” IEE proceedings-C, vol.138, pp.1.3-111,1991.
  • I.A.Chidambaram, B.Paramasivam, “Genetic algorithm based decentralized controllerfor
  • load-frequency control of
  • interconnected power systems with RFB considering TCPS
  • in the tie-line,” International journal of electronic engineering
  • research, Vol. 1, pp.299-312,2009.
  • J.B.X.Devota,M.G.Rabbani, S.Elangovan, “Effects of SMES
  • unit on AGC dynamcs,” Department of electrical engineering, National university of singapore IEEE catlouge No.98EX137,pp.61-661998.
  • S.K.Aditya,D.Das, “Battery energy storage for load
  • frequency control of an interconnected power system,” Electric power system research, Vol.58, pp.179- 185,2001.
  • B.Paramasivam, I,A,Chidambaram, “Bacterial foraging optimization load based frequency control of interconnected power systems with static synchronous series compensator,” International journal of latesttrends in computing,Vol.1,pp.7-13,2010.
  • Ravi Shankar, Kalyan Chatterjee, T.K.Chartterjee, “FACTS controller hydrothermal power system,” International journal of engineering science and technology, Vol.4,pp.1776- 1786,2012. for interconnected
  • H.Shayeghi, H.A.Shayanfar,A.Jalili, “LFC design of a
  • deregulated power system with TCPS using PSO,” world academy of science, engineering and technology, Vol.28,pp.570-578,2009.
  • Paramasivam Balasundaram, Chidambaram Iangi Akilandam, “ ABC algorithm based load-frequency controller for an interconnected power system considering nonlinearities and coordinated with UPFC and RFB,” International journal of engineering and Innovative technology, Vol.1, pp.1-11, 2012.
  • Tetsuo Sasaki, Toshihisa Kadoya, Kazuhiro Enomoto, “
  • Study on load frequency control using Redox flow batteries,” IEEE transactions on power systems, Vol.19, pp.660-667,2004.
  • K.Jagatheesan, B.Anand, “Dynamic Performance of
  • Multi-Area Hydro Thermal Power Systems with Integral Controller considering various performance Indices methods,” Proceedings of the IEEE International conference of Emerging trends in Science, Engineering and Technology (INCOSET), 2012, pp.474-478.
  • B.Anand, Ebenezer Jeyakumar.A., “Load Frequency
  • control with Fuzzy logic Controller considering Non- Linearities and Boiler Dynamics,” ACSE, Vol.8, pp .15- 20,2009.
  • M.Omar, M.Solimn, A.M.Abdel ghany, F.Bendary, “
  • Optimal tuning of PID controllers for hydrothermal load frequency control using ant colony optimization,” international journal on electrical engineering and informatics, Vol.5, No.3, pp.348-356,2013.
  • Lalit chandra saikia, Nidul Sinha, L.Nanda, “ Maiden
  • apllication of bacterial foraging based fuzzy IDD controller in AGC of a multi-area hydrothermal system,” Electric power and energy systems,, Vol.45, pp.98- 106,2013. [15] E.S.Ali, S.M.Abd-Elazim, “ Bacteria foraging
  • optimization algorithm based load frequency controller
  • foer interconnected power system,” Electric power and
  • energy systems,Vol.33,pp.633-688,2011. A.Ebrahim, [16] Mohamed Hossam E.Mostafa,
  • Saied.A.Gawish and Fahmy M.Bendary, “ Design of
  • decentralized load frequency based-PID controller using
  • stochastic Particle swarm optimization rechnique,”
  • inrernational conference on electric power and energy
  • conversion system, pp.1-6, 2009.
  • R.Arivoli, Dr.I.A.Chidambaram, “ Design of genetc
  • algorithm(GA) based controller for load-frequency control of power systems interconnected with AC-DC TIE-LINE,” Int J Sci. Engineering Tech, Vol.2, No.5, pp:280-286, 2011.
  • Ying-Tung Hsiao, Chen-long Chuang, Cheng-Chih
  • chien,” Ant colony optimization for designing of PID controllers,” IEEE international symposium on computer aided control systems design,pp:321-326, 2004
  • H.Shayeghi, H.A.Shayanfor, “ Application of ANN
  • technique based –synthesis to load frequency control of interconnected power and energy systems, Vol.28,pp. 503- 511, 2006.
  • Seyed Abbas Taher, Masoud Hajiakbari Fini, Saber Falahati
  • Aliabadi, “ Fractional order PID controller design for LFC in electric power systems using imperialist competitive algorithm, ” Ain Shams Engineerng journal, Vol.5, pp:121- 135, 2014.
  • S.Ramesh kumar, S.ganapathy, “ Cuckoo search optimizaion
  • algorithm based load frequency control of interconnectred power systems with GDB nonlinearity and SMES units,” International journal of engineering inventions, Vol.2, pp:23- 28,2013.
  • N.Tokuda, “Development of a Redox Flow battery systems,”
  • engineering conf., CO,IECE-98-1074,1998.
  • I.J. Nagrath, D.P. Kothari, “Power system engineering”, Tata
  • Mc-Graw Hill Publishing Company limited, 1994, New Delhi, India.
  • P.Kundur, “Power system stability and control”, Tata Mc
  • Graw Hill Publishing company limited, 1994, New Delhi, India.
  • O.I.Elgerd, “Electric Energy System Theory: An
  • Introduction”, Tata Mc-Graw Hill Publishing company limited,, New York,1970. pp.315-389
  • K.Jagatheesan was born on July 05, 1988.He