Radiation dose reports and determinants of image qualityduring ECG-triggered Cardiac Computed TomographyAngiography in children

Radiation dose reports and determinants of image qualityduring ECG-triggered Cardiac Computed TomographyAngiography in children

Aim: This study aimed to evaluate the radiation doses and determinants of image quality during prospective and retrospective ECG triggered cardiac computed tomography angiography. Materials and Methods: Patients included study who underwent ECG-triggered and low radiation dose dual-source cardiac computedtomography angiography scans. Dose length product values were obtained from the computed tomography scanning protocol.Effective dose (mSv) was estimated using the dose length product method with a conversion factor (mSv/mGy × cm). All imageswere evaluated and scored by two pediatric radiologists.Results: 37 patients have ECG-triggered cardiac computed tomography. The ages of the patients were between 3 days to 17 years(mean 73.78 ±79.95 months). The average heart rate of the patients was 101.11±27.12 bpm. The mean DLP was 93.05 ±64.4 mGy/ cm. The mean effective dose was calculated as 1.74 ±1.03 mSv. We found good agreement between observers while analyzingdeterminants of image quality (kappa values 0.71-0.80). Conclusion: High-quality images with a low dose can be obtained with an ECG-triggered cardiac computed tomography angiographymethod. Because of the high sensitivity of radiation in children, dose reduction techniques should be used effectively. Cardiaccomputed tomography examinations can be performed at diagnostic quality limits with prospective ECG-triggered technique inpatients with high pitch, low kV, and dual source techniques.

___

  • 1. Cheng Z, Wang X, Duan Y, et al. Low-dose prospective ECG-triggering dual-source CT angiography in infants and children with complex congenital heart disease: first experience. Eur Radiol 2010;20:2503-11.
  • 2. Glockler M, Halbfass J, Koch A, et al. Preoperative assessment of the aortic arch in children younger than 1 year with congenital heart disease: utility of lowdose high-pitch dual-source computed tomography. A single-center, retrospective analysis of 62 cases. Eur J Cardiothorac Surg 2014;45:1060-5.
  • 3. Koplay M, Kizilca O, Cimen D, et al. Prospective ECGgated high-pitch dual-source cardiac CT angiography in the diagnosis of congenital cardiovascular abnormalities: Radiation dose and diagnostic efficacy in a pediatric population. Diagn Interv Imaging 2016;97:1141-50.
  • 4. Bosmans H, Damilakis J, Ducou le Pointe H, et al. Radiation Protection No. 185 European Guidelines on Diagnostic Reference Levels for Paediatric Imaging. 2018.
  • 5. Barrera CA, Otero HJ, White AM, et al. Depiction of the native coronary arteries during ECG-triggered highpitch Dual-Source Coronary Computed Tomography Angiography in children: Determinants of image quality. Clinical imaging 2018;52:240-5.
  • 6. Saad MB, Rohnean A, Sigal-Cinqualbre A, et al. Evaluation of image quality and radiation dose of thoracic and coronary dual-source CT in 110 infants with congenital heart disease. Pediatric Radiology 2009;39:668-76.
  • 7. Kanie Y, Sato S, Tada A, et al. Image Quality of Coronary Arteries on Non-electrocardiography-gated High-Pitch Dual-Source Computed Tomography in Children with Congenital Heart Disease. Pediatr Cardiol 2017;38:1393-9.
  • 8. Goo HW, Park I-S, Ko JK, et al. Visibility of the origin and proximal course of coronary arteries on nonECG-gated heart CT in patients with congenital heart disease. Pediatr Radiol 2005;35:792-8.
  • 9. Karl TR. Tetralogy of Fallot: Current surgical perspective. Ann Pediatr Cardiol 2008;1:93-100.
  • 10. Giordano R, Cantinotti M, Di Tommaso L, et al. Surgical strategy for tetralogy of Fallot with abnormal coronary arteries. J Thorac Dis 2017;9:3447.
  • 11. Banderker E, Pretorius E, de Decker R. The role of cardiac CT angiography in the pre- and postoperative evaluation of tetralogy of Fallot. J SA Journal of Radiology 2015;19:1-9.
Annals of Medical Research-Cover
  • Yayın Aralığı: 12
  • Yayıncı: İnönü Üniversitesi Tıp Fakültesi
Sayıdaki Diğer Makaleler

Texture analysis from CT in discrimination of pancreaticductal adenocarcinoma and hypovascular pancreaticneuroendocrine neoplasm in the portal-venous phase

Kürşat DİKMEN, Aydın YAVUZ, Halit Nahit ŞENDUR, Mahi Nur CERİT, Emetullah CİNDİL, Tolga ZEYDANLI, Umut ASFUROĞLU, Ali Can YALÇIN, Hüseyin GOBUT, Koray KILIÇ

A dog tooth case stuck to the bone after bite

Yusuf TANRIKULU, Ceren ŞEN TANRIKULU, Serhat KARAMAN

Determining the relationship between marital adjustmentand risk of pregnancy: A case-control study

Tülay BÜLBÜL, Salime MUCUK

Relationship of serum vitamin D level with the clinical course of Adhesive Capsulitis

Mehmet Özbey BÜYÜKKUŞÇU, Betül BAŞAR, Hakan BAŞAR, Aslı BÜYÜKKUŞÇU

Detecting the presence of inflammation in fibromyalgiasyndrome with neutrophil/lymphocyte ratio, platelet/ lymphocyte ratio, and mean platelet volume

Murat GÜNTEL, Alper UYSAL

Surgical site infection associated with a rare agent,Chryseobacterium indologenes

Abdurrahman AYGÜL, Kerem YILMAZ

The validity and reliability of the Turkish version of the"parental satisfaction with caregiving for children withdevelopmental disabilities" scale

Hicran DOĞRU, Ali ÇAKIR

Validation and Cross-cultural Adaptation and Reliability ofthe Turkish Version of the Michigan Neuropathy ScreeningInstrument in the Eastern Anatolia Region of Turkey

Yusuf Kemal ARSLAN, Eren DÜZGÜN, Ceyda TANOĞLU, Dilek BADAY KESKİN

Hematological and muscle damage values in amateurplayers during football season

Hayrettin KARA, Erdil DURUKAN, Zekine PÜNDÜK, Aslan TOKLU

The prognostic role of the pretreatment peripheralneutrophil-lymphocyte ratio (NLR) and platelet lymphocyte ratio (PLR) in patients with cervical cancer

Günay CAN, İsmet ŞAHİNLER, Meltem DAĞDELEN, Şefika Arzu ERGEN, Ceren BARLAS