Polydioxanone suture fixation for the repair of pediatric maxillofacial fractures

Polydioxanone suture fixation for the repair of pediatric maxillofacial fractures

Aim: Unique pattern of the pediatric facial skeleton and its fractures confers a special issue to take into account. Conservativemanagement, occlusal splints and wiring techniques are popular among pediatric facial fractures. As titanium plates require plateremoval after the fracture healing, resorbable plates have gained popularity. However, they are expensive and it may not be possibleto obtain resorbable plates in some medical facilities. This led us to question the mechanical stability and functional outcome afterfracture fixation using polydioxanone (PDS) sutures.Material and Methods: Seven children with maxillofacial fractures were included in this study. After limited sufficient dissection andperiosteal striping the fracture lines were reduced and four holes were made with a drill on preoperatively planned sites where notooth buds were projected. After that a number 2 PDS loop suture was passed through these holes in a figure of eight fashion andtied to stitches after sufficient stability and anatomic reduction.Results: No complication occurred, except for two cases that had tooth extractions.Conclusion: To sum up, PDS suture fixation in a figure of eight fashion is a feasible and cheap alternative to titanium and resorbableplate systems.

___

  • 1. Aydin OE, Tan O, Algan S, et al. Maxillofacial fracture experiences: a review of 152 cases. Eurasian J Med 2012;44:141-3.
  • 2. Craig R, Dufresne PNM. Pediatric Facial Injuries. In: Mathes SJ, Hentz VR, editors. Plastic Surgery. 2nd edition. Philadelphia, Elsevier 2006;381-462.
  • 3. Dumbach J. Traction screw osteosynthesis after ramus osteotomy with resorbable osteosynthesis screws of polydioxanone (PDS)--initial results. Dtsch Z Mund Kiefer Gesichtschir 1984;8:145-8
  • 4. Rasse M, Schober C, Piehslinger E, et al. Intra- and extra-capsular condyle fractures in the growth period. Therapy, clinical course, complications. Dtsch Zahnarztl Z 1991;46:49-51.
  • 5. Bardach J, Kelly KM, Salyer KE. The effects of lip repair with and without soft-tissue undermining and delayed palate repair on maxillary growth: an experimental study in beagles. Plast Reconstr Surg 1994;94:343- 51.
  • 6. Smartt JM Jr, Low DW, Bartlett SP. The pediatric mandible: II. Management of traumatic injury or fracture. Plast Reconstr Surg 2005;116:28-41.
  • 7. Ashammakhi N, Renier D, Arnaud E, et al. Successful use of biosorb osteofixation devices in 165 cranial and maxillofacial cases: a multicenter report. J Craniofacial Surgery 2004;15:692-701.
  • 8. Eppley BL, Sadove AM, Havlik RJ. Resorbable plate fixation in pediatric craniofacial surgery. Plastic And Reconstructive Surgery 1997;100:1-7.
  • 9. Mackool R, Yim J, McCarthy JG. Delayed degradation in a resorbable plating system. J Craniofacial Surgery 2006;17:194-7.
  • 10. Bergsma EJ, Rozema FR, Bos RRM, et al. Foreign body reactions to resorbable poly (L-lactide) bone plates and screws used for the fixation of unstable zygomatic fractures. J Oral and Maxillofacial Surgery 1993;51:666-70.
  • 11. Nakamura T, Shimizu Y, Okumura N, et al. Tumorigenicity of poly L lactide (PLLA) plates compared with medical grade polyethylene. J Biomed Mater Res 1994;28:17- 25.
  • 12. Ikävalko M, Lehto MUK. Fractured rheumatoid elbow: Treatment with souter elbow arthroplasty--A clinical and radiologic midterm follow-up study. J Shoulder Elbow Surg 2001;10:256-9.
  • 13. Obwegeser JA. Osteosynthesis using biodegradable poly-p-dioxanon (PDS II) in Le Fort I--osteotomy without postoperative intermaxillary fixation. J Craniomaxillofac Surg 1994;22:129-37.
  • 14. van Sterkenburg S, Brutel de la Riviere A, Vermeulen F. Sternal fixation with resorbable suture material. Eur J Cardiothorac Surg 1990;4:345.
  • 15. Pihlajamäki H, Salminen S, Laitinen O, et al. Tissue response to polyglycolide, polydioxanone, polylevolactide, and metallic pins in cancellous bone: An experimental study on rabbits. J Orthop Res 2006;24:1597-606.
  • 16. Landes CA, Ballon A. Indications and limitations in resorbable P(L70/30DL)LA osteosyntheses of displaced mandibular fractures in 4.5-year follow-up. Plast Reconstr Surg. 2006;117:577-87.
Annals of Medical Research-Cover
  • Yayın Aralığı: Aylık
  • Yayıncı: İnönü Üniversitesi Tıp Fakültesi
Sayıdaki Diğer Makaleler

Extraction of endometrial polyps and type 0 submucosal fibroids under ultrasonographic guidance when hysteroscopy is not available

Mehmet BULBUL, Berna DİLBAZ

Different machine learning methods based prediction of mild cognitive impairment

Nadire ESER, Adem DOĞANER, Selma YAMAN, Tuğba ÖZCAN METİN

Effect of thermal aging procedure on the microhardness and surface roughness of fluoride containing materials

Magrur KAZAK, Nazmiye DONMEZ, Safiye Selin KOYMEN, Rabianur KOYMEN, Kerem TEKDEMİR

Plasma and salivary irisin levels in lepramatous leprosy patients

Mehmet KALAYCI, Emine TUGBA ALATAS, Asude KARA POLAT, Gursoy DOGAN, Asli AKIN BELLI

Clinicopathologic features of operated gastric cancer patients, single center nine years experience

Sinan YOL, Erdal POLAT, Orhan UZUN, Aziz Serkan SENCER, Mürşit DİNCER, Mustafa DUMAN, Kamuran Cumhur DEGER, Hüseyin CİGİLTEPE, Ebubekir GUNDES, Durmus Ali CETIN, Ulas ADAY

Efficacy of balloon kyphoplasty in pain management of vertebral compression fractures

Semra ISIK, Serdar ÇEVİK

Analysis of toxic plant and mushroom poisoning in children

Evrim GÜL, Mehmet Yusuf SARI

Evaluation of the effects of tadalafil on pain response in thermal plantar and dynamic plantar tests in rats

Duygu ALTINTAŞ AYKAN, Selma YAMAN

Crystallized phenol treatment is less effective in patients with recurrent pilonidal disease after surgery compared to patients with primary pilonidal disease

Mehmet Eren YÜKSEL

Effects of exercise on netrin-1 and TNF-α levels in noninflammatory conditions

Servet KIZILDAĞ, Ferda HOSGORLER, Oğuz YÜKSEL, Başar KOÇ, Sevim KANDİS, Güven GÜVENDİ, Nazan UYSAL