Correlation of pulse oximetry oxygen saturation with blood gas arterial oxygen saturation in patients with heart failure reduced ejection fraction: Prospective cohort study

Correlation of pulse oximetry oxygen saturation with blood gas arterial oxygen saturation in patients with heart failure reduced ejection fraction: Prospective cohort study

AbstractAim: An estimation of accurate oxygen saturation is a critical in the management of patients with heart failure (HF). However, obtaining peripheral arterial blood samples may be technically difficult in some cases. The purpose of this study was to evaluate the correlation of pulse oximetry SO2 with arterial SO2 in patients with HF reduced ejection fraction (HFrEF).Material and Methods: In total, 29 consecutive patients who were admitted to cardiology clinics with HFrEF were prospectively enrolled in this study. We enrolled all patients if the chief physician ordered an atrial blood gas analysis. Simultaneous atrial blood gas sample and pulse oximetry measurements were collected and compared. The strength of association between atrial blood gas and pulse oximetry measurements was determined by Pearson correlation and Bland and Altman analysis.Results: We evaluated 29 heart failure patients (the mean age was; 70.7±10.9, 44.8 % of patients were male) with a mean EF of 29.6 ± 5.5. We observed that the mean pulse oximetry SO2 and arterial SO2 in the study were 92.8 ± 4.4 and 93 ± 5.2, respectively. We found significantly positive linear correlation between two methods according to Pearson analysis (r = 0.683, p < 0.001). A low bias wasfound between two methods according to Bland and Altman method (-0.2296, p = 0.23).Conclusion: The present data may suggest that pulse oximetry oxygen saturation is an acceptable substitute for the arterial oxygen saturation in patients with HFrEF.

___

  • 1. Brandenburg MA, Dire DJ. Comparison of arterial and venous blood gas values in the initial emergency department evaluation of patients with diabetic ketoacidosis. Ann Emerg Med 1998;31:459−65.
  • 2. Gokel Y, Paydas S, Koseoglu Z, et al. Comparison of blood gas and acid−base measurements in arterial and venous blood samples in patients with uremic acidosis and diabetic ketoacidosis in the emergency room. Am J Nephrol 2000;20:319−23.
  • 3. J M Lozano, O R Duque, T Buitrago, et al. Pulse oximetry reference values at high altitude. Arch Dis Child 1992;67:299-301.
  • 4. Lim BL, Kelly AM. A meta-analysis on the utility of peripheral venous blood gas analyses in exacerbations of chronic obstructive pulmonary disease in the emergency department. Eur J Emerg Med 2010; 17:246-8.
  • 5. Masip J, De Mendoza D, Planas K, et al. Peripheral venous blood gases and pulse-oximetry in acute cardiogenic pulmonary oedema. Eur Heart J Acute Cardiovasc Care 2012;1:275-80.
  • 6. Van de Louw A, Cracco C, Cerf C, et al. Accuracy of pulse oximetry in the intensive care unit. Intensive Care Med 2001;27:1606-13.
  • 7. Holburn CJ, Allen MJ. Pulse oximetry in the accident and emergency department. Arch Emerg Med 1989; 6:137-42.
  • 8. Bierman MI, Stein KL, Snyder JV. Pulse oximetry in the postoperative care of cardiac surgical patients. A randomized controlled trail. Chest 1992;102:1367-70.
  • 9. Ibanez J, Velasco J, Raurich JM. The accuracy of the Biox 3700 pulse oximeter in patients receiving vasoactive therapy. Intensive Care Med 1991;17:484-6
  • 10. Jensen LA, Onyskiw JE, Prasad NG. Meta-analysis of arterial oxygen saturation monitoring by pulse oximetry in adults. Heart Lung 1998;27:387−408.
  • 11. Perkins GD, McAuley DF, Giles F, et al. Do changes in pulse oxymeter oxygen saturation predict equivalent changes in arterial oxygen saturation? Crit Care 2003; 7: 67.
  • 12. Seguin P, Le Rouzo A, Tanguy M, et al. Evidence for the need of bedside accuracy of pulse oximetry in an intensive care unit. Crit Care Med 2000;28:703-6.
  • 13. Hannhart B, Michalski H, Delorme N, et al. Reliability of six pulse oximeters in chronic obstructive pulmonary disease. Chest 1991;99:842-6.
  • 14. Secker C, Spiers P. Accuracy of pulse oximetry in patients with low systemic vascular resistance. Anaesthesia 1997;52:127-30.
  • 15. Zeserson E, Goodgame B, Hess JD, et al. Correlation of Venous Blood Gas and Pulse Oximetry with Arterial Blood Gas in the Undifferentiated Critically Ill Patient. J Intensive Care Med 2018; 33:176-81.
Annals of Medical Research-Cover
  • Yayın Aralığı: Aylık
  • Yayıncı: İnönü Üniversitesi Tıp Fakültesi
Sayıdaki Diğer Makaleler

Evaluation of hemogram parameters in smoking patients with coronary artery ectasia

Mehmet INANİR

Metoclopramide increased cell proliferation in HepG2 cell line and sorafenib attenuated the effect

Zeynep GUNES OZUNAL, Yaprak DONMEZ CAKİL, Sena TEKİN, Esra SAGLAM, Ranan AKTAS

Effects of alliin on renal ischemia reperfusion induced lung injury

Mustafa Can GULER, Ersen ERASLAN

Full cup test (FCT) for symptom severity assessment in carpal tunnel syndrome/comparing scores with clinical and neurophysiological findings

Esra Dilek KESKİN, Bahar SAY, Ufuk ERGUN, Hatice AGİR, Gulten KARACA

Surgical removal of a self-expanding metallic stent from jejunum in a patient with Roux-en-Y esophagojejunostomy

Kerem KARAMAN, Ozkan SUBASİ, Mehmet AZİRET, Ahmet Tarik EMİNLER, Aydın Seref KOKSAL

The effect of genetic on dental anxiety: Twin study

Damla TORUL, Mehmet Melih OMEZLİ, Kadircan KAHVECİ

Comparison of pregnancy outcomes in CC resistance PCOS patients undergoing CC plus letrozole and intra uterine insemination treatment with different follicular diameters

Serhat EGE

Fifty most cited Turkish Orthopedics and Traumatology articles in international literature: A bibliometric analysis

Mehmet YALCİNOZAN

The frequency of childhood abuse in bipolar disorder and its impact on the clinical course

Nesrin KARAMUSTAFAALİAGLU, Nesrin TOMRUK, Nihat ALPAY, Serhat CİTAK, Neslihan CANSEL

Complete blood count, Vitamin D, Vitamin B12, Hepatitis A and Hepatitis B screening results in students of faculty of dentistry

Burcu KAYHAN TETİK, Cengiz YAKİNCİ, Eda KAYHAN, Burak DAYİ