Accuracy of non-invasive hemoglobin monitoring by pulse CO-oximeter during hepatectomy in living liver donors

Accuracy of non-invasive hemoglobin monitoring by pulse CO-oximeter during hepatectomy in living liver donors

Aim: To evaluate the accuracy and agreement of the measurements made with the Masimo Rad7 device in living donor hepatectomy (LDH). Materials and Methods: A total of 63 living liver donors (LLDs) with ASA I-II scores who scheduled for LDH were included in the study. The Masimo noninvasive measurement probe was inserted to measure SpHb (mg/dL), pleth variability index (PVI, %) and perfusion index (PI,%). Heart rate, mean artery pressure, SpO2 , body temperature, BIS, PVI, SpHb, and PI were recorded as basal, after anesthesia induction, post-intubation, post-intubation plus 5 min, 10 min, and plus 1, 2, 3, 4, 5, 6 and 7h. In addition blood samples were collected for laboratory hemoglobin (Hblab) before the surgery incision and after the surgical procedure, and the values were recorded simultaneously with the other values. Results: Fifty-five LLDs age between 18 and 55 years were assessed. The mean PI value increased in all measurements compared to baseline, and it was statistically significant at the 5th minute (p

___

  • 1. Akbulut S, Yilmaz S. Liver transplantation in Turkey: historical review and future perspectives. Transplant Rev (Orlando) 2015;29:161-7.
  • 2. Onur A, Akbulut S, Dirican A, et al. Life-threatening or nearly life-threatening complications in living liver donors. Clin Transplant 2018;32:e13262.
  • 3. Garrett RR, Justin RP, William FP, at al. Left Hepatectomy Versus Right Hepatectomy for Living Donor Liver Transplantation: Shifting the Risk From the Donor to the Recipient. Liver Transpl 2013;19:472-81.
  • 4. Jacques L, Marisa T. Noninvasive or invasive hemoglobin measurement? Crit Care Med 2012;40:2715-16.
  • 5. McMurdy JW, Jay GD, Suner S, et al. Noninvasive optical, electrical, and acoustic methods of total hemoglobin determination. Clin Chem 2008;54:264- 72.
  • 6. Graybeal JM, Petterson M, Novak J. Correlation of peripheral perfusion index with site to site delays in detection of desaturations. Anesthesiology 2002;96:59.
  • 7. Lindner G, Exadaktylos AK. How noninvasive haemoglobin measurement with pulse co-oximetry can change your practice: An expert review. Emerg Med Int 2013;701529.
  • 8. Kutluturk K, Akbulut S, Baskiran A, et al. Aborted donor hepatectomy in living donor liver transplantation: lessons learned. S Afr J Surg 2020;58:91-100.
  • 9. Lauren B, Stephanie R, Erin M. Continuous noninvasive hemoglobin monitoring during complex spine surgery. Anesthesia and Analgesia 2011;6:1396-402.
  • 10. Rice MJ, Gravenstein N, Morey TE. Noninvasive hemoglobin monitoring: how accurate is enough? Anesthesia and Analgesia 2013;117:902-07.
  • 11. Medhat G, Bassant A, Dina Z, et al. Evaluation of Noninvasive Hemoglobin Monitoring in Trauma Patients with Low Hemoglobin Levels. Shock 2018;49:150-3.
  • 12. Bo T, Xuerong Y, Li X, et al. Continuous noninvasive hemoglobin monitoring estimates timing for detecting anemia better than clinicians: a randomized controlled trial. BMC Anesthesiology volume 2019;80.
  • 13. Frasca D, Dahyot-Fizelier C, Catherine K, et al. Accuracy of a continuous noninvasive hemoglobin monitor in intensive care unit patients. Crit Care Med 2011;39:2277.
  • 14. Miller RD, Ward TA, Shiboski SC, Cohen NH. A comparison of three methods of hemoglobin monitoring in patients undergoing spine surgery. Anesth Analg 2011;112:858-63.
  • 15. Gayat E, Bodin A, Sportiello C, et al. Performance evaluation of a noninvasive hemoglobin monitoring device. Ann Emerg Med 2011;57:330-33.
  • 16. Nguyen BV, Vincent JL, Nowak E, et al. The accuracy of noninvasive hemoglobin measurement by multiwave length pulse oximetry after cardiac surgery. Anesth Analg 2011;113: 1052-7.
  • 17. Seul GP, Oh HL, Yong HP, et al. The changes of noninvasive hemoglobin and perfusion index of Pulse CO-Oximetry during induction of general anesthesia. Korean J Anesthesiol 2015;68:352-7.
  • 18. Brianna C, Komal M, Terrence S, et al. Physiology, Stress Reaction. NCBI Bookshelf; StatPearls Publishing; 2021.
Annals of Medical Research-Cover
  • Yayın Aralığı: Aylık
  • Yayıncı: İnönü Üniversitesi Tıp Fakültesi
Sayıdaki Diğer Makaleler

Three-dimensional stereophotogrammetric analysis of facial soft tissues following bone-borne rapid maxillary expansion

Gökçenur GÖKÇE

Successful treatment with convalescent plasma in Covid-19 disease in relaps/refractory multiple myeloma

Emin KAYA, Mehmet Ali ERKURT, Irfan KUKU, Ahmet SARICI, Ilhami BERBER, Soykan BİÇİM, Mustafa ÖZGÜL

Investigation the etiology of syndromic autism with targeted gene analysis

Engin ATLI, Isik GORKER, Sinem YALCINTEPE, Cisem MAİL, Hakan GÜRKAN, Emine İkbal ATLİ, Leyla BOZATLI, Mengühan ARAZ ALTAY, Damla EKER, Selma DEMİR, Hasan Cem AYKUTLU

Opinions of nursing students about clinical practice; A qualitative study

Zeliha CENGİZ, Züleyha GÜRDAP, Ela KARACA, Merve ACUN

Computed tomography and magnetic resonance imaging features for differentiating functioning from non-functioning adrenal lesions

Dilek BERKER, Serdar GULER, Mazhar Müslüm TUNA, Narin NASİROGLU IMGA, Derya KÖSEOĞLU, Berçem AYÇİÇEK, Mehtap NAVDAR BASARAN, Cagdas SENEL, Altug TUNCEL

Evaluating the effects of two different lipid emulsions on morbidities in premature infants

Leyla BİLGİN, Yesim COSKUN, Burak DELİLOGLU, Secil ERCİN

Evaluation of healthcare professionals' fears and quality of life regarding COVID-19; comparison of the two physician groups

Arzu ÇALIŞKAN DEMİR, Sukru AYDİN

Accuracy of non-invasive hemoglobin monitoring by pulse CO-oximeter during hepatectomy in living liver donors

Duygu DEMİROZ ASLAN, Yusuf Ziya COLAK

The impact of previous open abdominal surgery on the outcome of laparoscopic colorectal surgery

Uğur TOPAL, Ahmet Gökhan SARITAŞ, Orcun YALAV, Ahmet RENCUZOĞULLARI, İsmail Cem ERAY, Kubilay DALCI

Vitreoretinal surgery in patients with intraocular lens dislocation into the vitreous

Seyhan DİKCİ, Turgut YILMAZ