A morphometric study of the odontoid process using three-dimensional computed tomography (3-D CT) reconstruction

A morphometric study of the odontoid process using three-dimensional computed tomography (3-D CT) reconstruction

The aim of this study was to evaluate the morphometric parameters of the odontoid process using 3-dimensional (3D) reconstruction of computed tomography (CT) images and investigate the applicability of using one or two screwsfor fixing odontoid process fractures.Methods: CT images of 100 patients (55 males, 45 females) were transferred to the OsiriX program in DICOM format and converted into three dimensional images using the 3D volume rendering feature. Male and female groups were divided into 8–30,31–50 and over 50 age groups and features of the odontoid process were measured.Results: In the coronal plane, the minimum external transverse length of the odontoid process (OPmin) was highest in malesover 50 year of age with a value of 11.3 mm. In the sagittal plane, the combination of anterior-posterior length of the odontoidprocess and vertebral body (OPAP) was highest in the males over 50 (14.5 mm). The length of the line taken from the anteriorinferior corner of the vertebral body to the top of odontoid process (LAIT) was measured the highest measured as 45.2 mm inmales over 50. These measurements were higher in males than females.Conclusion: The results of this study showed that it is possible to use a single 4.5 mm or 3.5 mm cannulated screw in theTurkish population. The application of two 3.5 mm screws was found to be appropriate in 76% of males and 62% offemales.

___

  • 1. fiahino¤lu K, transl. editor. Moore KL, Dalley AF, Agur AMR. Klini¤e yönelik anatomi. ‹stanbul: Nobel T›p Kitabevleri; 2015. p. 1136.
  • 2. Moore KL, Dalley II AF. Clinically oriented anatomy. 4th ed. Philadelphia (PA): Lippincott Williams and Wilkins; 1999. p. 1164.
  • 3. Ar›nc› K, Elhan A. Anatomi. Ankara: Günefl Kitabevi; 2014. p. 856.
  • 4. Holdsworth F. Fractures, dislocations, and fracture-dislocations of the spine. J Bone Joint Surg Am 1970;52:1534–51.
  • 5. Standring S, editor. Gray’s anatomy: the anatomical basis of clinical practice. 40th ed. Edinburgh: Elsevier Churchill Livingstone; 2008. p. 1576.
  • 6. Gövsa Gökmen F. Sistematik anatomi. ‹zmir: Güven Kitabevi; 2008. 7. Cramer GD. The cervical region. In: Cramer GD, Darby SA, editors. Clinical anatomy of the spine, spinal cord, and ANS. 3rd ed. St. Louis (MO): Mosby; 2014. p. 135–209
  • 8. Korres DS. Fractures of the odontoid process. In: Korres DS, editor. The axis vertebra. Berlin: Springer-Verlag; 2013. p. 45–59
  • 9. Akobo S, Rizk E, Loukas M, Chapman JR, Oskouian RJ, Tubbs RS. The odontoid process: a comprehensive review of its anatomy, embryology, and variations. Childs Nerv Syst 2015;31:2025–34.
  • 10. Böhler J. Anterior stabilization for acute fractures and non-unions of the dens. J Bone Joint Surg Am 1982;64:18–27.
  • 11. Bednar DA, Parikh J, Hummel J. Management of type II odontoid process fractures in geriatric patients; a prospective study of sequential cohorts with attention to survivorship. J Spinal Disord 1995;166– 9.
  • 12. Henry AD, Bohly J, Grosse A. Fixation of odontoid fractures by an anterior screw. J Bone Joint Surg Br 1999;81:472–7.
  • 13. Cloché T, Vital JM. Chirurgie des traumatismes récents du rachis cervical. EMC - Techniques chirurgicales - Orthopedie-Traumatologie 2016;11:1-28 [Article 44– 176].
  • 14. Daher MT, Daher S, Nogueira-Barbosa MH, Defino HLA. Computed tomographic evaluation of odontoid process: implications for anterior screw fixation of odontoid fractures in an adult population. Eur Spine J 2011;20:1908–14.
  • 15. Apfelbaum RI, Lonser RR, Veres R, Casey A. Direct anterior screw fixation for recent and remote odontoid fractures. J Neurosurg 2000;227–36.
  • 16. Nucci RC, Seigal S, Merola AA, Gorup J, Mroczek KJ, Dryer J, Zipnick RI, Haher TR. Computed tomographic evaluation of the normal adult odontoid. Implications for internal fixation. Spine (Phila Pa 1976) 1995;20:264–70.
  • 17. Yusof MI, Yusof AH, Abdullah MS, Hussin TM. Computed tomographic evaluation of the odontoid process for two-screw fixation in type-II fracture: a Malaysian perspective. J Orthop Surg (Hong Kong) 2007;15:67–72.
  • 18. Schaffler MB, Alson MD, Heller JG, Garfin SR. Morphology of the dens. A quantitative study. Spine (Phila Pa 1976) 1992;17:738– 43.
  • 19. Korres DS, Lazaretos J, Papailiou J, Kyriakopoulos E, Chytas D, Efstathopoulos NE, Nikolaou VS. Morphometric analysis of the odontoid process: using computed tomography--in the Greek population. Eur J Orthop Surg Traumatol 2016;26:119–25.
  • 20. Nakanishi T, Sasaki T, Takahata T, Aoki Y, Sueyasu MU, M, Washiya S IK. Internal fixation of odontoid process. Orthop Surg Traumatol 1980;23:399–406.
  • 21. Doherty BJ, Heggeness MH, Esses SI. A biomechanical study of odontoid fractures and fracture fixation. Spine (Phila Pa 1976) 199318:178–84.
  • 22. Tun K, Kaptanoglu E, Cemil B, Yorubulut M, Karahan ST, Tekdemir I. Anatomical study of axis for odontoid screw thickness, length, and angle. Eur Spine J 2009;8:271–5.