Three-dimensionally-navigated cross-cannulated screw fixation for traumatic pubic symphysis diastasis: an anatomical study

Objective: The aim of this study was to design and optimize the secure corridor of cross-cannulated screw implantation in pubic symphysis through Orbic 3D (Siemens Medical Solutions, Erlangen, Germany) computerized navigation and to provide an anatomic basis through the study of regional anatomy.Methods: Fifteen embalmed adult cadavers (8 males, 7 females) were used in this study. All pelvic specimens were placed in the supine position on a radiolucent carbon fiber table. The ideal angle of screw placement, appropriate screw diameter, and perfect attachment point were determined by the computerized navigation system. According to the above data, cross-cannulated screws 6.5 mm in diameter were implanted by the guide pins. Based on detailed local dissection, the entry-exit points of double screws were exposed in the pelvis. The distances were measured between the entry-exit points and the major structures. Radiographs and computed tomography (CT) scans of the pelvis were performed to reassess the position of screws.Results: The trajectory of the first screw originated from the trailing edge of the pubic tubercula to the anterior-lower corner of the contralateral pubic tubercula. The second screw was directed from the base of the pubic tubercula to the junctional zone between the pubic tubercula and inferior ramus of the pubis of the opposite side of the body. Both screws maintained a safe distance from the surrounding major structures. All screw corridors were found intact without any damage under X-ray and CT images.Conclusion: The Orbic 3D computer navigation system is a reliable and new method of achieving a secure corridor for screw implantation in the pubic symphysis

___

Pohlemann T, Bosch U, Gänsslen A, Tscherne H. The Hannover experience in management of pelvic fractures. Clin Orthop Relat Res 1994;305:69-80.

Sagi HC, Papp S. Comparative radiographic and clinical outcome of two-hole and multi-hole symphyseal plating. J Orthop Trauma 2008;22:373-8.

Tile M. Fracture of the pelvis and acetabulum. 2nd ed. Bal- timore: Williams and Wilkins 1995:284-91.

Mu WD, Xu SH, Zhou DS. Anatomic basis and applica- tion of percutaneous screw placement guided with com- puter-assisted navigation in pelvic and acetabular fracture. Chin Med J 2010;26:986-90.

Simonian PT, Schwappach JR, Routt ML Jr, Agnew SG, Harrington RM, Tencer AF. Evaluation of new plate de- signs for symphysis pubis internal fixation. J Trauma. 1996;41:498-502.

Van Loon P, Kuhn S, Hofmann A, Hessmann MH, Rom- mens PM. Radiological analysis, operative management and functional outcome of open book pelvic lesions: a 13- year cohort study. Injury 2011;42:1012-9.

Wilson CJ, Edwards R. Massive extraperitoneal hemor- rhage after soft tissue trauma to the pubic branch of the inferior epigastric artery. J Trauma 2000;48:779-80.

Luijendijk RW, Jeekel J, Storm RK, Schutte PJ, Hop WC, Drogendijk AC, et al. The low transverse Pfannenstiel inci- sion and the prevalence of incisional hernia and nerve en- trapment. Ann Surg 1997;225:365,9.

Chen L, Zhang G, Song D, Guo X, Yuan W. A comparison of percutaneous reduction and screw fixation versus open reduction and plate fixation of traumatic symphysis pubis diastasis. Arch Orthop Trauma Surg 2012;132:265-70.

Mu WD, Wang H, Zhou DS, Yu LZ, Jia TH, Li LX. Computer navigated percutaneous screw fixation for trau- matic pubic symphysis diastasis of unstable pelvic ring in- juries. Chin Med J (Engl) 2009;122:1699-703.

Yin CG, Liu J, Xu P. Quantitative anatomical study of per- cutaneous cannulated lag screw fixation for treatment of symphysis pubis diastasis. Chin Med J 2014;30:589-93.

Cano-Luis P, Giráldez-Sanchez MA, Martínez-Reina J, Serrano-Escalante FJ, Galleguillos-Rioboo C, Lázaro- Gonzálvez A, et al. Biomechanical analysis of a new mini- mally invasive system for osteosynthesis of pubis symphy- sis disruption. Injury 2012;43 Suppl 2:20-7.

Ruan Z, Luo CF, Zeng BF, Zhang CQ. Percutaneous screw fixation for the acetabular fracture with quadrilateral plate involved by three-dimensional fluoroscopy naviga- tion: surgical technique. Injury 2012;43:517-21.

Lindahl J, Hirvensalo E. Outcome of operatively treat- ed type-C injuries of the pelvic ring. Acta Orthop 2005;76:667-78.

Lindahl J, Hirvensalo E, Böstman O, Santavirta S. Failure of reduction with an external fixator in the management of injuries of the pelvic ring. Long-term evaluation of 110 patients. J Bone Joint Surg Br 1999;81:955-62.

Xu P, Wang H, Liu ZY, Mu WD, Xu SH, Wang LB, Chen C, Cavanaugh JM. An evaluation of three-dimensional image-guided technologies in percutaneous pelvic and ace- tabular lag screw placement. J Surg Res 2013;185:338-46.

Virkus WV, Goldberg SH, Lorenz EP. A comparison of compressive force generation by plating and intramedullary nailing techniques in a transverse diaphyseal humerus frac- ture model. J Trauma 2008;65:103-8.

Yu KH, Hong JJ, Chen LW. Comparison of the biome- chanical stability of cannulated screw and reconstruction plate for the fixation of symphysis pubis diastasis. Journal of Medical Biomechanics 2010;25:475-8.

Varga E, Hearn T, Powell J, Tile M. Effects of method of internal fixation of symphyseal disruptions on stability of the pelvic ring. Injury 1995;26:75-80.

Ma K, Zhu L, Fang Y. A preliminary anatomical study on design of cannulated screw channels for fixation of symphysis pubis diastasis in small samples. [Article in Chinese] Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi 2014;28:43-6. [Abstract]

Dienstknecht T, Müller M, Sellei R, Nerlich M, Müller FJ, Fuechtmeier B, et al. Screw placement in percutaneous acetabular surgery: gender differences of anatomical land- marks in a cadaveric study. Int Orthop 2013;37:673-9.

Mendel T, Radetzki F, Wohlrab D, Stock K, Hofmann GO, Noser H. CT-based 3-D visualisation of secure bone corridors and optimal trajectories for sacroiliac screws. In- jury 2013;44:957-63.

Puchwein P, Enninghorst N, Sisak K, Ortner T, Schild- hauer TA, Balogh ZJ, et al. Percutaneous fixation of ac- etabular fractures: computer-assisted determination of safe zones, angles and lengths for screw insertion. Arch Orthop Trauma Surg 2012;132:805-11.

Mouhsine E, Garofalo R, Borens O, Wettstein M, Blanc CH, Fischer JF, et al. Percutaneous retrograde screwing for stabilisation of acetabular fractures. Injury 2005;36:1330- 6.

Peng KT, Huang KC, Chen MC, Li YY, Hsu RW. Per- cutaneous placement of iliosacral screws for unstable pel- vic ring injuries: comparison between one and two C-arm fluoroscopic techniques. J Trauma 2006;60:602,8.

Rajasekaran S, Vidyadhara S, Ramesh P, Shetty AP. Ran- domized clinical study to compare the accuracy of navigat- ed and non-navigated thoracic pedicle screws in deformity correction surgeries. Spine (Phila Pa 1976) 2007;32:E56- 64.

Nakashima H, Sato K, Ando T, Inoh H, Nakamura H. Comparison of the percutaneous screw placement preci- sion of isocentric C-arm 3-dimensional fluoroscopy-nav- igated pedicle screw implantation and conventional fluo- roscopy method with minimally invasive surgery. J Spinal Disord Tech 2009;22:468-72.

Behrendt D, Mütze M, Steinke H, Koestler M, Josten C, Böhme J. Evaluation of 2D and 3D navigation for il- iosacral screw fixation. Int J Comput Assist Radiol Surg 2012;7:249-55.

Gras F, Marintschev I, Klos K, Mückley T, Hofmann GO, Kahler DM. Screw placement for acetabular fractures: which navigation modality (2-dimensional vs. 3-dimen- sional) should be used? An experimental study. J Orthop Trauma 2012;26:466-73.

Ochs BG, Gonser C, Shiozawa T, Badke A, Weise K, Rolauffs B, et al. Computer-assisted periacetabular screw placement: Comparison of different fluoroscopy-based navigation procedures with conventional technique. Injury 2010;41:1297-305.
Acta Orthopaedica et Traumatologica Turcica-Cover
  • ISSN: 1017-995X
  • Başlangıç: 2015
  • Yayıncı: Türk Ortopedi ve Travmatoloji Derneği
Sayıdaki Diğer Makaleler

Prognostic factors in sensory recovery after digital nerve repair

TUĞRUL BULUT, ULAŞ AKGÜN, ATİLLA ÇITLAK, Cihan ASLAN, Ufuk ŞENER, Muhittin ŞENER

Reconstruction of advanced periacetabular metastatic lesions with modified Harrington procedure

BÜLENT EROL, AHMET NADİR AYDEMİR, Tolga ONAY, Mert Osman TOPKAR

An emerging etiological factor for hand injuries in the pediatric population: public exercise equipment

Berrak AKŞAM, ERSİN AKŞAM, Candemir CERAN, MUSTAFA EROL DEMİRSEREN

Role of anti-adhesive barriers following rotator cuff repair surgery: an experimental study

MAHMUT KALEM, Ercan ŞAHİN, Murat SONGÜR, SİNAN ZEHİR, Mehmet ARMANGİL, Mehmet A DEMİRTAŞ

Fixation of extra-articular distal humeral fractures with a lateral approach and a locked plate: an alternative method

Atilla Sancar PARMAKSIZOĞLU, Ufuk ÖZKAYA, Fuat BİLGİLİ, Harun MUTLU, Ümit ÇETİN

Oxford Knee Score: cross-cultural adaptation and validation of the Turkish version in patients with osteoarthritis of the knee

Baki Umut TUĞAY, Nazan TUĞAY, Hande GÜNEY, GİZEM İREM KINIKLI, İnci YÜKSEL, Bülent ATİLLA

A novel biological reconstruction of tibial bone defects arising after resection of tumors

Bilal DEMİR, Umut YAVUZ, Evren AKPINAR, Erdem ÖZDEN

A new complication in volar locking plating of the distal radius: longitudinal fractures of the near cortex

Tahir Sadık SÜGÜN, Yusuf GÜRBÜZ, Kemal ÖZAKSAR, Tulgar TOROS, Emin BAL, Murat KAYALAR

Clinical utilization of arterial occlusion pressure estimation method in lower limb surgery: effectiveness of tourniquet pressures

BAHATTİN TUNCALI, Hakan BOYA, Zeynep KAYHAN, Şükrü ARAÇ, Mehmet Ali Koray ÇAMURDAN

Three-dimensionally-navigated cross-cannulated screw fixation for traumatic pubic symphysis diastasis: an anatomical study

Guangchao SUN, Chengguo YIN, Zhiyong LIU, Lubo WANG, Weidong MU